Installing The Gas Outlet Casing; Fig. 74: Fitting Gas Outlet Casing Without Support; Table 49: Tightening Torque (51009) - ABB HT846019 User Manual

Table of Contents

Advertisement

Operation Manual / A150-M58/68
10 Dismantling and fitting with removed air inlet and gas outlet /

10.19 Installing the gas outlet casing

10.19
Installing the gas outlet casing
Variant without support
Fig. 74: Fitting gas outlet casing without support
Product
A150-M58/68
Table 49: Tightening torque (51009)
1. Coat thread of bolts (51008) with high-temperature grease.
2. Insert a new gasket (61002) into the gas outlet casing (61001).
3. Fit swivel lifting eyes (S) to the gas outlet casing (61001). Secure lifting gear to the swivel
lifting eye.
4. Place gas outlet casing at turbine casing (51000). Observe the marking.
5. Fit hexagon nuts (51009). Observe the tightening torque.
6. Fit insulation ring. Observe tightening torques (see
7. If present: Attach waste gate pipe. Tighten in accordance with enginebuilder's specifica-
tions.
© Copyright 2021 ABB. All rights reserved.
Size
Tightening torque [Nm]
M16
Table of tightening torques
HZTL4041_EN
200
→91).
Rev.E
January 2021

Advertisement

Table of Contents
loading

This manual is also suitable for:

A150-m58

Table of Contents