1.0 INTRODUCTION
General purpose canister load cells manufactured by PCB
Load & Torque are suitable for a wide range of general force
measurement applications, including weighing, dynamometer
use, and static material test machines.
operate in tension and compression. Standard 1/4"-28 female
threads facilitate ease of installation.
Tensile Load
Tensile Load
Figure 1 – Canister Load Cell Loading
The following document explains the characteristics and
installation of the canister load cells.

2.0 SAFETY PRECAUTIONS

Failure of the load cell structure may cause personal injury
and equipment damage.
The load cell can withstand loads of at least 150% of the full-
scale capacity before any damage occurs to the sensing
element. Be sure that the load cell and any fixturing used is
properly designed, fabricated, and securely installed prior to
use.
3.0 OVERVIEW
Canister load cells come in a variety of capacities to handle
loads ranging from 25 lbf to 300 lbf.
Table 1 - Full-Scale Capacities
Full-Scale Capacities
Model
1102-05A
1102-01A
1102-02A
1102-03A
1102-04A
M1102-05A
M1102-01A
M1102-02A
M1102-03A
M1102-04A
CANISTER LOAD CELL OPERATION MANUAL
These load cells
Compression Load
Compression Load
(lbf)
(N)
25
110
50
222
100
445
200
900
300
1334
28
125
56
250
112
500
225
1000
337
1500
PCB Load & Torque
Toll-Free in USA 866-684-7107
3.1 Dimensions
2
8
9
Figure 2 - Dimensions
Table 2 - Dimension Values
Dimensions
1102
(see Figure 2)
(in)
∅2.75
1
∅0.44
2
∅1.75
3
4
1.50
5
0.09
6
0.06
7
3.17
8
¼"-28 Tapped
9
¼"-28 Tapped
3.2 Optional Components
Table 3 - Optional Components
Item Number
181-012A
PT06A-10-6S (SR), Mating Connector
8311-01-10A
Cable – Non-Coax, PT65 to Pigtail, 10 feet

4.0 MECHANICAL INSTALLATION

Loads applied to canister load cells must be even and centered.
Compensation linkages (e.g. rod end bearing, alignment
couplers)
are
recommended
misalignment. When installing fixtures, be sure to thread the
fixture to the load cell, and not the load cell to the fixture. If
alignment fixtures are not used, ensure loading surfaces are
flat and parallel, with loads applied in-line with the sensor.
716-684-0001
www.pcb.com
1
5
4
7
6
3
Series Number
M1102
(mm)
(in)
(mm)
∅69.9
∅2.75
∅69.9
∅11.2
∅0.44
∅11.2
∅44.5
∅1.75
∅44.5
38.1
1.50
38.1
2.3
0.09
2.3
1.5
0.06
1.5
80.5
3.17
80.5
M6x1.0 Tapped
M6x1.0 Tapped