Middleby APW Wyott GGM-18S Owner's Manual

Gas griddle

Advertisement

Quick Links

GAS GRIDDLE
MODELS:
GGM-18S, GGM-24S, GGM-36S, GGM-48S
GGT-18S, GGT-24S, GGT-36S, GGT-48S
OWNERS MANUAL
2M-Z23811 Rev. B (12-21)
GGT-36S
This manual includes material related to installation, use , cleaning, and care. Exploded view[s], as well as any available
parts list[s] and wiring diagram[s] pertaining to the unit[s] covered by this manual are also included.
This manual must be read and understood by all persons using or installing this appliance. Contact your Star dealer
if you have any questions concerning installation, use, or maintenance of this equipment.
DO NOT DISCARD THIS MANUAL.
is a registered trademark of APW Wyott®, A Middleby Company. All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the APW Wyott GGM-18S and is the answer not in the manual?

Questions and answers

Summary of Contents for Middleby APW Wyott GGM-18S

  • Page 1 This manual must be read and understood by all persons using or installing this appliance. Contact your Star dealer if you have any questions concerning installation, use, or maintenance of this equipment. DO NOT DISCARD THIS MANUAL. is a registered trademark of APW Wyott®, A Middleby Company. All rights reserved.
  • Page 2: Safety Symbols

    SAFETY SYMBOLS These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance. THOROUGHLY INSPECT YOUR UNIT ON ARRIVAL This unit has been tested for proper operation before leaving our plant to ensure delivery of your unit in perfect condition.
  • Page 3 221 (100.2) 236 (107.0) 4742 SQ. CM. 44-3/4 981 SQ. IN. GGM-48S 48 (121.9) 29 (73.7) 15-1/2 (39.4) 80,000 295 (133.8) 315 (142.9) (113.7) 6329 SQ. CM. is a registered trademark of APW Wyott®, A Middleby Company. All rights reserved.
  • Page 4: General Installation Data

    GENERAL INSTALLATION DATA This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. CAUTION The APW Wyott model griddles are equipped for use with the types of gas specified on the nameplate.
  • Page 5 EXHAUST CANOPY It is essential that facilities be provided over the griddle to carry off fumes and gases. However, the unit should not be directly connected to a flue or stack. LEVELING UNIT This griddle is supplied with (4) feet which must be screwed into the legs attached to the body. Level unit by adjusting the (4) feet which have an adjustment of 1-3/4"...
  • Page 6 LIGHTING INSTRUCTIONS When griddle is first lit, it will smoke until the preservation oils and impurities are burned off. 1. Turn off main valve to unit and wait 5 minutes to clear gas. 2. Turn off all knobs and pilot valves. 3.
  • Page 7: Grease Pan

    COOKING (MODELS TD) Set the thermostat dial knob to the temperature desired. After a short preheating period, the thermostat will automatically maintain the selected temperature. GREASE PAN A grease pan is located at the front and can be removed for cleaning from the front. This pan should be checked and emptied on a regular basis.
  • Page 8 FRONT—PANEL AND CONTROLS RIGHT SIDE—PANELS GGT-36S shown REAR PANEL LEFT SIDE—PANELS GGT-36S shown is a registered trademark of APW Wyott®, A Middleby Company. All rights reserved.
  • Page 9 BOTTOM 17 21 GGT-36S shown THERMOSTAT AND BURNERS GGT-36S shown THERMOSTAT [GGT MODELS ONLY] is a registered trademark of APW Wyott®, A Middleby Company. All rights reserved.
  • Page 10: Parts List

    PARTS LIST NOTE: Side references are from the operator’s point-of-view – from the front of the unit. Items labeled “NS” are non-serviceable. Items labeled “NP” are not pictured. MODEL PART NUMBER DESCRIPTION PAGE NO GGM-18S GGM-24S GGM-36S GGM-48S 2F-Z5949 U-BURNER GGT-18S GGT-24S GGT-36S...
  • Page 11 PARTS LIST MODEL PART NUMBER DESCRIPTION PAGE NO GGM-18S/GGT-18S G4-Z23858 PANEL, REAR 18 INCH GGM-24S/GGT-24S G3-Z5953 PANEL, REAR 24 INCH GGM-36S/GGT-36S G3-Z5955 PANEL, REAR 36 INCH GGM-48S/GGT-36S G3-Z5957 PANEL, REAR 48 INCH GGM-18S/GGT-18S G3-615304 GREASE CHUTE ASSEMBLY ALL OTHER MODELS G3-624304 GGM-18S/GGT-18S G4-Z23862...
  • Page 12 PARTS LIST MODEL PART NUMBER DESCRIPTION PAGE NO GGT-18S GGT-24S 2T-Z4293 THERMOSTAT GGT-36S GGT-48S GGT-18S GGT-24S 2K-Y7111 ASSEMBLED FITTING, 90 DEG GGT-36S GGT-48S GGT-18S GGT-24S 2K-Z4921 CORRUGATED BURNER TUBE GGT-36S GGT-48S GGT-18S GGT-24S G3-Z4398 BULB CAP GGT-36S GGT-48S GGT-18S GGT-24S 2C-6517 NUT, 1/4-20 GGT-36S...
  • Page 13 PARTS LIST MODEL PART NUMBER DESCRIPTION PAGE NO 2M-8830100 BADGE, APW WYOTT G3-Z5945 SIDE PANEL 2A-Z5942 6, 7 G3-624302 LINER ASSEMBLY, LEFT G3-624303 LINER ASSEMBLY, RIGHT GGM-18S/GGT-18S G4-Z23857 CENTER WALL, 18 INCH GGM-24S/GGT-24S G3-Z5915 CENTER WALL, 24 INCH GGM-36S/GGT-36S G3-Z5925 CENTER WALL, 36 INCH GGM-48S/GGT-36S G3-Z5935...
  • Page 14 LIMITED EQUIPMENT WARRANTY WARRANTY EXCLUSIONS APW warrants to the original purchaser of new APW's products to be THE FOLLOWING WILL NOT BE COVERED UNDER WARRANTY. APWs’ sole obligation under this warranty is limited to either repair free from defects in material or workmanship, under normal and proper use and maintenance service as specified by APW and upon proper or replacement parts, subject to the additional limitations installation and start-up in accordance with the instructions...
  • Page 15 NOTES...
  • Page 16 Printed in the U.S.A. • 2M-Z23811 • Rev B (12-21) Specifications are subject to change without notice. 265 Hobson St. • Smithville, TN 37166 is a registered trademark of APW Wyott®, A Middleby Company. All rights reserved. Telephone: (800)-264-7827 • Fax: (314)-781-5445...

Table of Contents