HOBO® Data Node, Ext Temp/RH, Analog, Pulse (ZW-005)
HOBO Data Node (ZW-005)
Included Items:
• AC adapter (AC-ZW-1)
• Temp/RH cable
• 3 AAA batteries
• 1 locking screw
• Hook & loop tape
• Adhesive label
• Bracket kit (ZW-BRACKET)
13556-E MAN-ZW-005
The HOBO ZW-005 data node is configured with a temperature/RH channel designed to accept
the included temperature/RH cable, along with one analog and one pulse channel. The analog
channel accepts a wide range of Onset and third-party sensors/transducers with 0–2.5 VDC
output, including temperature and AC current sensors. Specifications for Onset sensors are
available at onsetcomp.com or from an Onset Authorized Dealer. For 0–5 VDC, 0–10 VDC, or
4–20 mA output, use optional Onset part numbers CABLE-ADAP5, CABLE-ADAP10, or CABLE 4-
20 mA respectively. CABLE-2.5-STEREO is required to connect to the pulse channel (connect the
pulse output device to the cable's black and white leads).
This node has routing capability in the ZW wireless network when initially powered with an AC
adapter. Refer to the HOBO ZW Series Wireless Network Quick Start Guide for information on
how to set up this node.
External power jack
for AC adapter
(AC-ZW-1)
Reset button
* Caution: Analog channel input cannot exceed 2.5 VDC. For sensor outputs up to 10 VDC, use
appropriate voltage adapter cable.
Specifications
Radio power
1.6 mW (2 dBm)
Transmission range
Approx. 100 m (328 ft), depending on obstructions or interference
Wireless data standard
IEEE 802.15.4, 2.4 GHz band
Measurement ranges
Temperature: -40° to 70°C (-40 to 158°F)
RH: 0 to 100% RH, -40° to 70°C (-40° to 158°F)
Analog channel: 0 to 2.5 VDC, 0 to 5 VDC (with CABLE-ADAP5), 0 to 10 VDC
(with CABLE-ADAP10), 4-20mA (with CABLE-4-20-mA)
Pulse channel
CABLE-2.5-STEREO required
Maximum input frequency: 120 Hz (120 pulses per second)
Measurement range: 0 to 65,535 pulses per logging interval
Resolution: 1 pulse
Recommended input type: Electronic solid state switch closure or CMOS-level
digital output (example: FET, opto-FET or open collector)
Minimum pulse width: 1 ms
Input/output impedance: 100 KΩ
Maximum input voltage: 2.8 V
Bits per sample: 16
Accuracy
Temperature: ±0.21°C from 0 to 50°C (±0.38°F from 32° to 122°F); see Plot A
RH: ± 2.5% from 10 to 90% typical, max. ± 3.5% including hysteresis
Analog channel: ± 1.544 mV plus 2% of reading typical
Resolution
Temperature: 0.02°C at 25°C (0.04°F at 77°F)
RH: 0.0.3%
Analog channel: 0.6 mV
Response time
Temperature: 5 minutes in air moving 1 m/sec (3.3 ft/sec)
RH: 10 minutes in air moving 1 m/sec (3.3 ft/sec) with protective cap
Operating temperature
-20° to 50°C (-4° to 122°F) when battery powered, -20° to 70° C (-4° to 158°F)
when line powered
Operating RH
5% to 95% non-condensing
Stability (drift)
Temperature: < 0.1°C (0.18°F) per year
RH: <1% per year typical; hysteresis 1%
Status LEDs
Locking screw hole
Analog Channel (A1)*
Temperature/RH cable port
Battery compartment cover/case mount
Pulse Channel (P1)

Advertisement

loading

Summary of Contents for Onset HOBO ZW-005

  • Page 1 Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com HOBO® Data Node, Ext Temp/RH, Analog, Pulse (ZW-005) The HOBO ZW-005 data node is configured with a temperature/RH channel designed to accept the included temperature/RH cable, along with one analog and one pulse channel. The analog channel accepts a wide range of Onset and third-party sensors/transducers with 0–2.5 VDC...
  • Page 2 • Consult the dealer or an experienced radio/TV technician for help Changes or modifications not expressly approved by Onset Computer Corporation could void the user's authority to operate the equipment. To comply with FCC and Industry Canada RF radiation exposure limits for general population, the HOBO data nodes, receivers, and routers must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.