Advertisement

Quick Links

PS1300N
USER'S MANUAL
MA29-02/B
12/09/2011
www.davicia.com

Advertisement

Table of Contents
loading

Summary of Contents for DAVI & CIA PS1300N

  • Page 1 PS1300N USER’S MANUAL MA29-02/B 12/09/2011 www.davicia.com...
  • Page 2: Table Of Contents

    USER’S MANUAL MA29-02/B INDEX Page 1. 1. 1. 1. DESCRIPTION DESCRIPTION DESCRIPTION DESCRIPTION 2. 2. 2. 2. INSTALLATION INSTALLATION INSTALLATION INSTALLATION 2.1. Scale assembly 2.2. Location and setting 2.3. Startup 3. 3. 3. 3. OPERATION OPERATION OPERATION OPERATION 3.1. LCD symbol description 3.2.
  • Page 3 USER’S MANUAL MA29-02/B 1. DESCRIPTION Display unit Mounting holes for height rod accessories Scale platform Adjustable feet...
  • Page 4: Installation

    USER’S MANUAL MA29-02/B 2. INSTALLATION Before putting the device into use, please read with care the information given in the Operating Instructions. They contain important instructions for installation, proper use and maintenance of the device. The manufacturer shall not be liable for damages arising out of failure to heed the following instructions: When using electrical components under increased safety requirements, always comply with the appropriate regulations.
  • Page 5: Startup

    USER’S MANUAL MA29-02/B 2.3. STARTUP . STARTUP . STARTUP . STARTUP Connect the equipment to the power supply using the AC adaptor. Press the ON/OFF button in the indicator. Wait until “0” appears on display.
  • Page 6: Operation

    USER’S MANUAL MA29-02/B 3. OPERATION Before reading detailed instructions on how to use all the weighing functions that are built into your scale, please read the following important guidelines: Always be sure that the display shows `Zero` before use, if it does not then please press the ZERO key. The equipment is designed to detect when a stable weight is achieved, your reading should be taken at this point.
  • Page 7: Key Functions

    USER’S MANUAL MA29-02/B 3.2..KEY FUNCTIONS KEY FUNCTIONS KEY FUNCTIONS KEY FUNCTIONS Designation Designation Designation Designation Function Function Function Function ON/OFF-switch Turn ON/OFF the scale PRINT button Data transmission via interface(Print-out the results) BMI button Determine Body Mass Index HOLD button To hold weighing result on the display / determine stable weighing value ZERO setting key...
  • Page 8: Hold

    USER’S MANUAL MA29-02/B When“0,00 kg 0,00 kg 0,00 kg 0,00 kg” displays on the screen and scale beeps twice, place the object (clothes) to be tared on the tray. Press [TARE] [TARE] key after the weight stabilizes and stable sign appears on the display. [TARE] [TARE] Display will return to “0,00 kg...
  • Page 9: Pre-Tare

    USER’S MANUAL MA29-02/B 3.7..PRE PRE- - - - TARE TARE TARE TARE The scale can store 5 sets of pre-tare values, and there are two methods to store pre-tare value – Using Dead Weight or Enter weight using 0~9 keys: Using Dead Weight Description Description...
  • Page 10 USER’S MANUAL MA29-02/B The instrument will make flash and beep sound and will display the saved Pre- Tare Weight. Recall Pre-Tare Value: Description Description Example Example Description Description Example Example Long press PRE-TARE key for 3 seconds; the display will show the blinking m sign. Press numeral key 1 ~ 5 to choose pre Press numeral key 1 ~ 5 to choose pre Press numeral key 1 ~ 5 to choose pre...
  • Page 11: Setup

    USER’S MANUAL MA29-02/B 4. SETUP Switch ON the scale and long press [ZERO] [ZERO] [ZERO] [ZERO] key for 3 seconds. First “SETUP” and then “A.OFF” will display successively. Auto-off time setup This enables operator to select the auto turn OFF time of the device. Auto off time: Auto off time: 120 sec/180 sec/240 sec/300 sec/Off Auto off time:...
  • Page 12: Print Function

    USER’S MANUAL MA29-02/B Parity check: None Data length: 8 bits Stop bit: 1 bit Handshake: RTS/CTS Data code: ASCII. 4.2..PRINT FUNCTION PRINT FUNCTION PRINT FUNCTION PRINT FUNCTION The Weighing, BMI and Height results can be printed-out for records using RS232 interface cable (included in accessory kit), which is connected with the round plug at the back terminal.
  • Page 13: Maintenance Maintenance And Cleaning Maintenance And Cleaning

    USER’S MANUAL MA29-02/B 5. MAINTENANCE AND CLEANING The scale does not require any routine maintenance. However, we recommend checking the scale’s accuracy at regular intervals. The regularity of these checks is dependent on the level of use and the state of the scale. We would recommend using alcohol based wipes or similar when cleaning the scale.
  • Page 14: Troubleshooting

    USER’S MANUAL MA29-02/B 6. TROUBLESHOOTING Error Message Error Message Error Message Error Message Reason Reason Reason Reason Action Action Action Action Low Battery: This warning shows Please replace a new battery or plug the AC that the voltage of battery is too adaptor for operation low to use Overload: The total load exceeds...
  • Page 15: Height Height Rod Accessories Height Rod Accessories

    USER’S MANUAL MA29-02/B 7. HEIGHT ROD ACCESSORIES AC1200D AC1200D is a digital height rod to be mounted on the scale with measuring range from (120~200cm). AC1200D have LCD display for convenient, accurate and quick height measurement. It can be connected with the scale indicator to transfer the height measurements directly, therefore while calculating BMI the users don’t need to enter the height.
  • Page 16: Battery Installation

    USER’S MANUAL MA29-02/B Extend the height measuring rod and tighten it in the bracket with the help of the appertaining screw. 7.2..BATTERY INSTALLATION BATTERY INSTALLATION BATTERY INSTALLATION BATTERY INSTALLATION AC1200M don’t need batteries to operate AC1200D Remove the battery cover at the rear of indicator.
  • Page 17: Key Functions

    USER’S MANUAL MA29-02/B 7.3. KEY FUNCTIONS 7.3. KEY FUNCTIONS 7.3. KEY FUNCTIONS 7.3. KEY FUNCTIONS Keys Keys Keys Keys Description Description Description Description ON/OFF Press to switch on and off. UNIT To select the measurement unit between cm and inch. To enable value store function during measuring.
  • Page 18: Using The Height Rod

    USER’S MANUAL MA29-02/B 7.5..USING THE HEIGHT ROD USING THE HEIGHT ROD USING THE HEIGHT ROD USING THE HEIGHT ROD AC1200D AC1200M Slide up the measuring rod upward. Slide the measuring rod upward. Slide down the head piece until slightly touches Slide down the head piece until slightly touches the head.
  • Page 19: Technical Specifications

    USER’S MANUAL MA29-02/B 7.7..TEC TECHNICAL SPECIFICATIONS HNICAL SPECIFICATIONS HNICAL SPECIFICATIONS HNICAL SPECIFICATIONS Model Model Model Model AC1200D AC1200M Type Type Type Type Scale mounted digital height rod Keys Keys Hold, Reset, Unit Reset Button Keys Keys 120~200cm (Digital measuring range) Measurement range Measurement range...
  • Page 20: Technical Specifications Technical Specifications

    USER’S MANUAL MA29-02/B 8. TECHNICAL SPECIFICATIONS Model: PS1300N Capacity: 300 kg x 100 g LCD Display: 1.0 inch LCD display with 5 and 1/2 digits Max. external dimensions: 360 x 520 x 1020 mm Power supply: AC adapter 15V 300mA / Rechargeable Battery...
  • Page 21: Warranty Certificate

    USER’S MANUAL MA29-02/B 9. WARRANTY CERTIFICATE We provide a 1 1 1 1 - - - - yea year r r r guarantee from the date of purchase. The guarantee covers manufacturing defects or defects occurring as a result of normal use and operation. It excludes all removable parts such as batteries, wires, power supply devices, etc.
  • Page 22: Ce Declaration Of Conformity

    E08830 Sant Boi de Llobregat BARCELONA - ESPAÑA DECLARAN BAJO SU RESPONSABILIDAD QUE EL PRODUCTO: DECLARE UNDER THEIR RESPONSIBILITY THAT THE PRODUCT Marca DAVI & CIA Brand Nombre PS1300N Name Tipo EQUIPO ELECTRONICO Type Electronic equipment Finalidad Prevista Equipo pesapersonas.
  • Page 23 USER’S MANUAL MA29-02/B This manual and other support documents are available on the web www.davicia.com www.davicia.com www.davicia.com www.davicia.com C/ Murcia, 35 Nave G Pol.industrial Can Calderón. Tel. +34 93 654 32 32 info@davicia.com E 08830 Sant Boi de Llobregat. Barcelona. Spain Fax.

Table of Contents