Do you have a question about the 94275 and is the answer not in the manual?
Questions and answers
Summary of Contents for Central Pneumatic 94275
Page 1
DUST RECLAIMER KIT (FOR USE WITH MODEL 94274 INDUSTRIAL BLAST CABINET) Model 94275 INSTALLATION AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. ® 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com...
Distractions can cause you to lose control. Protect others in the work area from debris such as chips and sparks. Provide barriers or shields as needed. For technical questions, please call 1-800-444-3353. SKU 94275 PRODUCT SPECIFICATIONS For Use with Model 94274 Industrial Blast Cabinet 115 VAC / 60 Hz / 12.0 Amps / 18,900...
Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts. For technical questions, please call 1-800-444-3353. SKU 94275 ELECTRICAL SAFETY PERSONAL SAFETY eliminates the need for the...
Page 4
Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one tool may become hazardous when used on another tool. For technical questions, please call 1-800-444-3353. SKU 94275 TOOL USE AND CARE PAGE 4...
(California Health & Safety Code § 25249.5, et seq.) For technical questions, please call 1-800-444-3353. SKU 94275 SERVICE SPECIFIC SAFETY RULES Do not attempt to force small tools and...
Page 6
Do not handle the Power Cord Plug (12) with wet hands. Never plug the Power Cord of this product into an electrical outlet while standing on a wet on a wet or damp surface. For technical questions, please call 1-800-444-3353. SKU 94275 PAGE 6...
Page 7
The plug and outlet should look like those in the following illustration. (See Figure A.) THIS PRODUCT USES A 3-PRONG PLUG FIGURE A For technical questions, please call 1-800-444-3353. SKU 94275 GROUNDING WARNING! 115 VOLT, GROUNDED, ELECTRICAL OUTLET...
If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use. For technical questions, please call 1-800-444-3353. SKU 94275 FIGURE B EXTENSION CORDS...
Page 9
When unpacking, check to make sure all the parts shown on the Parts List on page 19 are included. If any parts are missing or broken, please call Harbor Freight Tools at: 1-800- 444-3353 as soon as possible. For technical questions, please call 1-800-444-3353. SKU 94275 (120 OR 240 VOLT) EXTENSION CORD LENGTH 50 Feet...
Install the Hose Connector (48) using four M5x12 bolts (47) as shown in Figure 2 below. Re-install the Exhaust Board over the Hose Connector (48) (see Figure 1). Figure 1 Exhaust Board For technical questions, please call 1-800-444-3353. SKU 94275 ASSEMBLY INSTRUCTIONS Figure 2 PAGE 10...
Page 11
Reclaimer and its contents. Prior to drilling mounting holes in a wall surface, check to make sure there are no hidden electrical cables, gas or plumbing pipes in the drilling path. Figure 3 For technical questions, please call 1-800-444-3353. SKU 94275 9.52” 9.52” PAGE 11...
Page 12
See Figure 4 below. Figure 4 Attach the dust reclaimer to the wall using Flat Washers (35), Spring Washers (36) and Hex Nuts (46). See Figure 5 below. Figure 5 For technical questions, please call 1-800-444-3353. SKU 94275 PAGE 12...
Page 13
After attaching the Dust Reclaimer to the wall, it should look like it does in Figure 6 below. Figure 6 Attach the blast cabinet to the Dust Reclaimer as shown in Figure 7, then firmly tighten up the Hose Clamps (15). Figure 7 For technical questions, please call 1-800-444-3353. SKU 94275 PAGE 13...
Page 14
Take out the Exhaust Board (see to Figure 8). Install the Hose Connector (48) using four Bolts (47) as shown in Figure 9. Figure 8 Exhaust Board Re-install the Exhaust Board as shown in Figure 8 Figure 9 For technical questions, please call 1-800-444-3353. SKU 94275 PAGE 14...
Page 15
Figure 10 below. Make sure the Support Brackets are parallel with the dust collector hose nozzle. After ensuring the support brackets center line is in line with that of the dust collector hose, firmly tighten up the Hex Nuts (31). See Figure 10 Below.
Page 16
32 while it is against the back of the blast cabinet. If you have a newer version of blast cabinet SKU 94275, there will be bolts and nuts already in the holes where the Dust Reclaimer will be attached to the Blast Cabinet.
A. Make sure the Power Cord Plug (12) of the Dust Reclaimer is unplugged from its electrical outlet. (See Assy. Diagram.) B. Release the Latch (27), and open the Dust Collector Cap (26) at the bottom of the Dust Reclaimer. Then, allow the dust and debris to pour out into a proper waste container.
D. Replace the Filter (18) and Radiating Guard (1). (See Assy. Diagram.) Problem Dust Reclaimer does not turn on. Poor visibility within the Blast Cabinet. For technical questions, please call 1-800-444-3353. SKU 94275 TROUBLESHOOTING Possible Solution Make sure the Power Switch (25) on is in its “ON” position.
ASSEMBLY DIAGRAM NOTE: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. For technical questions, please call 1-800-444-3353. SKU 94275 PAGE 19...
ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO. For technical questions, please call 1-800-444-3353. SKU 94275 Parts List PARTS LIST Qty Part# Description...
Page 21
This warranty gives you specific legal rights and you may also have other rights which vary from state to state. 3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • (800) 444-3353 REV 11h For technical questions, please call 1-800-444-3353. SKU 94275 PAGE 21...
Need help?
Do you have a question about the 94275 and is the answer not in the manual?
Questions and answers