Storage; Storage After Use - Echo CS-7310P Operator's Manual

Table of Contents

Advertisement

STORAGE

ENGINE PROBLEM TROUBLESHOOTING CHART
Problem
Check
Spark plug
Engine
runs, but
Carburetor
dies
or
Cooling
system
Engine
does not
acceler-
Spark
ate
arrestor
properly
screen
Engine
does not
crank
Fuel vapors are extremely flammable and can cause fire and/or
explosion. Never test for ignition spark by grounding spark plug
near cylinder plug hole, otherwise serious personal injury can
result.
STORAGE

Storage After Use

Units equipped with a Momentary STOP Switch automatically
return to RUN position. Engine can start unintentionally. Always
remove spark plug lead from spark plug before assembling or
performing maintenance procedures. Serious personal injury
can result.
• Inspect and adjust every part of the chainsaw.
• Completely clean every part and repair if necessary.
• Apply thin coating of oil on metal parts to prevent rust.
56
Status
Plug dirty
Normal wear
or worn
Improper
Vibration
adjustment
Cooling
Extended oper-
system
ation in dirty or
dirty or
dusty locations
plugged
Spark
arrestor
Normal wear
screen
plugged
Internal engine
N/A
problem
Cause
Clean and adjust
or replace
Adjust
Clean
Replace
See your dealer
© 11/21 ECHO Incorporated
CS-7310P
Remedy
X7503340002

Advertisement

Table of Contents
loading