sure you have read, understand and are following all
information provided in the Important Safety Information
section of this manual. Failure to follow those instructions
can cause death, serious injury or property damage.
Prior to each gas fire table operation, check the hose and
valve for evidence of excessive abrasion or wear.
BURNER CONNECTIONS
Make sure the regulator valve and hose connections are
securely fastened to the burner and the tank. If your unit
was assembled for you, visually check the connection
between the burner pipe and orifi ce. Make sure the burner
pipe fi ts over the orifi ce.
!
WARNING Failure to inspect this connection or
follow these instructions could cause a fi re or an
explosion, which can cause death, serious bodily
injury, or damage to property.
Please refer to diagram for proper installation.
If the burner pipe does not rest fl ush to the orifi ce
please contact Real Flame at 1-800-654-1704 for
assistance.
CHECKING FOR LEAKS
Make a leak check solution by mixing 1 part dish
washing soap with 3 parts water in a spray bottle.
Make sure control knob is OFF. Then, turn LP gas
tank to ON at valve.
Spray leak solution on valve connections paying
particular attention to the areas indicated by arrows.
If any bubbles appear turn LP gas tank OFF,
reconnect and re-test. If you continue to see bubbles
after several attempts, disconnect LP gas source and
contact Real Flame at 1-800-654-1704 for assistance.
If no bubbles appear after one minute turn tank OFF,
wipe away solution and proceed.
!
WARNING Before using this outdoor fi re table, make

PRE-USE INSTRUCTIONS

Burner Pipe
Check for leaks at these locations
Orifi ce is located
in this connection