Specifications - NY Thermal Trinity Lx-WH Series Installation And Operation Manual

Table of Contents

Advertisement

│Installation and Operation Manual
Trinity Lx-WH

2.0 SPECIFICATIONS

Table 2-1 General Specifications
DESCRIPTION
Lx200WH
Gas Connection
(inches, NPT)
Water Connections
1" (Female)
(inches, NPT)
Exhaust Vent
Connection (inches)
Air-inlet Connection
(inches)
Cabinet Height
(inches)
Cabinet Width
(inches)
Cabinet Depth
(inches)
Approximate Weight
with water (lbs)
Water Content
(gallons)
Electrical Rating
Table 2-2(a) Water Heater Performance Specifications
DESCRIPTION
Lx200WH
CSA Input
25 - 199
1
Modulation (MBH)
Recovery Rating at
1,2
100⁰F Rise (GPH)
Thermal Efficiency
2
(%)
Notes:
1
Listed Input and Output ratings are at minimum vent lengths at Sea Level. Numbers will be lower with longer venting
and/or altitudes greater than 2000 feet [610 m].
2
Based on standard test procedures prescribed by the U.S. Department of Energy. Ratings have been confirmed by AHRI.
High Altitude Operation
The Trinity Lx is designed to operate at its maximum listed capacity in installations less than or equal to 2000 ft
[610 m] above Sea Level. Since the density of air decreases as elevation increases, maximum specified capacity
should be de-rated for elevations above 2000 ft [610 m] in accordance with Table 2-3.
Table 2-3 De-rate % for High Altitudes
Elevations
2000 ft [610 m]
1
In Canada
de-rate by 10%
2
In USA
Notes:
1
Canada: Altitudes between 2000-4500 ft [610-1372 m], de-rate by 10%. Consult local authorities for de-rating
capacities for altitudes above 4500 ft [1372 m].
2
USA: De-rate capacity by 4% for every 1000 ft [305 m], if altitude is over 2000 ft [610 m].
Combustion – At elevations above 2000 feet, the combustion of the water heater must
be checked with a calibrated combustion analyzer to ensure safe and reliable operation.
It is the Installers responsibility to check the combustion and to adjust the
combustion in accordance to Section 9.0. Failure to follow these instructions may
result in property damage, serious injury, or death.
6
Lx300WH
½" (Female)
1-1/4" (Female)
3
3
29.5
36
18.5
21.5
125
180
1.2
2.1
Lx300WH
Lx400WH
55 - 275
75 - 399
229
317
3000 ft [914 m]
de-rate by 10%
-
de-rate by 12%
Lx400WH
Lx500WH
¾" (Female)
4
4
43
17
24
32.5
225
320
2.4
3.3
120V / 1 Phase / 60 Hz / 12A
Lx500WH
Lx600WH
100 - 500
120 - 600
460
576
96
4000 ft [1219 m]
4500 ft [1372 m]
de-rate by 10%
de-rate by 10%
de-rate by 16%
de-rate by 18%
Lx – WH Series
Lx700WH
Lx600WH
Lx800WH
1" (Male)
2" (Female)
6
37
47.5
63.5
380
475
4
5.2
Lx700WH
Lx800WH
160 - 700
160 - 800
691
806
5000 ft [1524 m]
de-rate % may vary
de-rate by 20%
922