External Connection - Samsung SSA-R2000V User Manual

Rfid reader
Table of Contents

Advertisement

EXTERNAL CONNECTION

WIRING DIAGRAM
Wiegand Data 0 Out
Wiegand Data 1 Out
Tamper Switch Out(NC)
Tamper Switch Out(COM)
CONTROLLER
Buzzer Control In
LED Control In(Green)
LED Control In(Orange)
Category
Connect the DC+12V to the red line.
Power Supply Unit
Connect GND to the black line.
Connect the green line of the product to the Wiegand D0 input port of the controller.
Wiegand Connection
Connect the white line of the product to the Wiegand D1 input port of the controller.
Enables you to turn on or off the LED indicators.
LED Control
To control the green indicator, connect the yellow line; to control the orange indicator, connect the blue line
with white stripes, to the output port of the controller. (see page 12)
Enables you to turn on or off the buzzer.
Buzzer Control
To control the buzzer, connect the blue line to the controller's output (relay). (see page 12)
Connect the COM port (Pink line) of the product's tamper switch to GND; connect the NC port (Light yellow)
Tamper Control
of the tamper switch to the input port of the controller.
Connect to the COM port of the PC. (Connect pin 2 of the DB-9 connector to the purple line; connect the
RS-232 Connection
orange line to pin #5 of the DB-9 connector)
SSA-R2000V
Green
White
Light yellow
Pink
Blue
Yellow
Gray
SSA-R2000V
Red
Black
DC +12V
GND
POWER
Cable Wiring
RS-232(TX)
Purple
PC
RS-232(GND)
Orange
English _ 11

Advertisement