  • Page 2 SAFETY INSTRUCTIONS Please read and follow these safety guidelines to safeguard yourself and others: GSM switch-gate controller GS-500 (later referred to as “the system” or “ the device”) contains a built-in radio transceiver operating in • GSM 850/900/1800/1900 MHz bands.
  • Page 3: Table Of Contents

    CONTENTS 1. GENERAL INFORMATION ................................6 2. TECHNICAL SPECIFICATIONS ..............................6 2.1. Electrical & Mechanical Characteristics .................................6 2.2. Main Unit, LED Indicator & Connector Functionality ........................... 7 2.3. Wiring Diagrams ........................................8 3. INSTALLATION ...................................9 4. GENERAL OPERATION ................................10 5. CONFIGURATION METHODS ..............................10 5.1.
  • Page 4 Manual GS-500_EN_2014-01...
  • Page 5 The buyer agrees that the system will reduce the risk of fire, theft, burglary or other danger but that it does not guarantee against the occurrence of such events. Entrya Technologies BVBA will not take any responsibility for the loss of personal effects, property or revenue whilst using the system.
  • Page 6: General Information

    1. GENERAL INFORMATION GS-500 is a micro-controller based device intended to provide access control for gate automatics, road barriers or to remotely turn ON/OFF any electrical appliance via the GSM network. Examples of using the system: Access control. • Parking lot control of residential houses or offices.
  • Page 7: Main Unit, Led Indicator & Connector Functionality

    2.2. Main Unit, LED Indicator & Connector Functionality GSM (r) GSM (g) STATUS G S M SIM CARD MO DE M PROG AC/DC OUT1 OUT2 COM IN3 IN2 IN1 Main Unit Functionality GSM antenna SMA type connector Mini USB port SIM CARD SIM card slot / holder GSM MODEM...
  • Page 8: Wiring Diagrams

    RELAY1 RELAY2 COM Z3 Power supply Gate automatics Gate automatics device device Example of GS-500 system wiring to gate automation device Control board gate opener GS-500 AC/DC OUT1 OUT2 COM IN3 IN2 IN1 L N PE PE 24 V Push...
  • Page 9: Installation

    4. Once the PIN code and voice mail are disabled, insert the SIM card into the SIM card slot / holder of GS-500 system. 5. Make sure the antenna is connected and power up the system, wait until indicator GSM (r) goes out indicating SIM card status.
  • Page 10: General Operation

    If the caller is one of the 5 administrators or the phone number belongs to one of the 500 database users, the system will reject the phone call, thus making the phone call free of charge, and open the gate. By ringing to GS-500 again, it will close the gate. If the phone number is not recognized, the system will reject the phone call and ignore it.
  • Page 11 SMS text message content: View remote ssss_SETGPRS? configuration Value: ssss – 4-digit SMS password. parameters Example: 1111_SETGPRS? Config This operation may be carried out from the PC using the GS-Configurator software. Tool This operation may be remotely carried out from the PC using the web browser. BROWSER 5.4.1.
  • Page 12: System Language

    2. Open a web browser and type in http://gs-configurator.entrya.eu/ 3. Enter the received login details and press Login button. 4. After the system configuration is complete, use one of the following methods to end the configuration process: • Wait for the session timeout and the system to reply with an SMS text message confirming the end of the session.
  • Page 13: Sms Password

    SMS text messages from the system’s inputs (see 14.1. Input Names and Alarm Notification). GS-500 allows to assign output C1, output C2 or both outputs (simultaneous control) to a certain administrator. By default, the system ignores any incoming calls and SMS text messages from a non-preset phone number as well as it rejects the SMS text messages containing wrong SMS password even from a preset administrator phone number.
  • Page 14 SMS text message content: View administrator ssss_HELPNR phone numbers Value: ssss – 4-digit SMS password. Example: 1111_HELPNR Config This operation may be carried out from the PC using the GS-Configurator software. Tool This operation may be remotely carried out from the PC using the web browser. BROWSER Assign output Config...
  • Page 15: Date And Time

    9. DATE AND TIME The system comes equipped with internal real-time clock (RTC) that keeps track of the current date and time. Once the system is up and running, the user must set the correct date and time, otherwise the system will not operate properly. After shutting down and starting up the system, the date and time must be set again.
  • Page 16 By default, the date and time synchronization period is 30 days. To set a different period, please refer to the following configuration methods. Config Set synchronization This operation may be carried out from the PC using the GS-Configurator software. Tool period This operation may be remotely carried out from the PC using the web browser.
  • Page 17: User Phone Number Database

    The system comes equipped with a user database of 500 user capacity. When the phone number is set, the user will be able to control the output (-s) by free of charge phone call. GS-500 user database allows to assign output C1, output C2 or both outputs (simultaneous control) to a certain user.
  • Page 18 SMS text message content: View users phone ssss_GETALLNUMBERS numbers Value: ssss – 4-digit SMS password. Example: 1111_GETALLNUMBERS Config This operation may be carried out from the PC using the GS-Configurator software. Tool This operation may be remotely carried out from the PC using the web browser. BROWSER SMS text message content: Search for user by...
  • Page 19 SMS text message content: ssss_D:ALL Delete all users Value: ssss – 4-digit SMS password. Example: 1111_D:ALL 1. Keep the USR/PROG button pressed for 30 seconds. 2. The blue STATUS LED light will start to flash rapidly and then stops. 3. All user numbers are deleted. Config This operation may be carried out from the PC using the GS-Configurator software.
  • Page 20: User Validity And Access Restriction

    10.1. User Validity and Access Restriction The system allows to restrict access in accordance with the scheduler assigned to a certain user. When one or more schedulers are assigned, the user will be able to control the output only on the specified weekdays and time set up in the scheduler. The system allows to assign up to 8 different schedulers.
  • Page 21 SMS text message content: Extend deadline for ssss_EXPIRYTIME_ttteeellnnuumm_extendmins ssss_EXPIRYTIME_user-name_ individual user extendmins Value: ssss – 4-digit SMS password; ttteeellnnuumm – up to 15 digits user phone num- ber; extendmins – time period, range – [1... 2147483648] minutes; user-name – up to 16 characters user name.
  • Page 22 SMS text message content: Set ring counter for ssss_RCOUNT_ttteeellnnuumm_numofcalls ssss_RCOUNT_user-name_numofcalls individual user Value: ssss – 4-digit SMS password; ttteeellnnuumm – up to 15 digits administrator phone number; user-name – up to 16 characters user name; numofcalls – number of phone calls, range –...
  • Page 23: Outputs

    11. OUTPUTS GS-500 comes equipped with 2 built-in outputs. The outputs are intended for connection and control of the gate automation device by the following methods: • Free of charge phone call from the user or administrator phone number (see 11.2. Output Control by Free of Charge Phone Call).
  • Page 24: Output Control By Free Of Charge Phone Call

    11.2. Output Control by Free of Charge Phone Call To open or close the gate, dial the system’s phone number from any available user or administrator phone numbers (see 10. USER PHONE NUMBER DATABASE and 8. ADMINISTRATOR PHONE NUMBERS for phone number management). The phone call is free of charge as the system rejects it and turns ON the output (-s) for the preset time period (pulse;...
  • Page 25: Output Control By Sms Text Message

    11.3. Output Control by SMS Text Message To open or close the gate, send the SMS text message from any of 5 available administrator phone numbers (see 8. ADMINISTRATOR PHONE NUMBER for phone number management). The system will turn ON the outputs for a determined time period (pulse) resulting in the gate opening or closing, depending on the current gate state.
  • Page 26 To instantly turn ON/OFF the specified output and set its state to ON/OFF when the system starts-up, please refer to the following configuration methods. SMS text message content: Turn OFF output/Set ssss_Co:OFF ssss_out-name:OFF output start-up state Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; out-name – up to as OFF 16 characters output name.
  • Page 27: Output Control Confirmation By Call Back

    11.4. Output Control Confirmation by Call Back The system can make a phone call confirming that the output control action has been successfully carried out. Once enabled, every output control action will be followed by a 5-second (by default) ring to the user/administrator phone number that the output control by free of charge phone call was initiated from.
  • Page 28: Automatic Output Control

    SMS text message content: Disable output ssss_STR:OFF control from any Value: ssss – 4-digit SMS password. phone number Example: 1111_STR:OFF Config This operation may be carried out from the PC using the GS-Configurator software. Tool This operation may be remotely carried out from the PC using the web browser. BROWSER NOTE: The system will accept SMS text messages only from a preset administrator phone number even if output control from any...
  • Page 29: Schedulers

    12. SCHEDULERS The system comes equipped with 8 schedulers that allow to set up the day (-s) of the week and time parameters. The schedulers are used to set up user access restriction (see 10.1. User Validity and Access Restriction) as well as automatic output control (see 11.6. Automatic Output Control).
  • Page 30 SMS text message content: ssss_SCHEDc_st:hr:mn Set start time Value: ssss – 4-digit SMS password; c – scheduler number; hr – hours, range – [00... 23]; mn – minutes, range – [00... 59]. Example: 1111_SCHED2_ST:20:25 Config This operation may be carried out from the PC using the GS-Configurator software. Tool This operation may be remotely carried out from the PC using the web browser.
  • Page 31: Event Log

    13. EVENT LOG This feature allows to chronologically register up to 1000 timestamped records regarding the following system events: • Output control including the user/administrator phone number and user name. • User validity expiry by deadline. • User validity expiry by ring counter. • Automatic output control beginning.
  • Page 32 The event log may be set as of FIFO (first in, first out) type that allows the system to automatically replace the oldest records with the latest ones. By default, FIFO type event log is disabled. To enable/disable it, please refer to the following configuration methods. Config Enable FIFO type log This operation may be carried out from the PC using the GS-Configurator software.
  • Page 33: Inputs

    14. INPUTS The system comes equipped with 3 inputs designed for fault indication output or detection device connection, such as door contacts. Once a fault indication output and/or a detection device is triggered, the system will send a notification SMS to the administrator phone number. Typically, the inputs are used to receive notifications regarding jammed gate or gate state.
  • Page 34 SMS text message content: ssss_STATUS View input names Value: ssss – 4-digit SMS password. Example: 1111_STATUS Config This operation may be carried out from the PC using the GS-Configurator software. Tool This operation may be remotely carried out from the PC using the web browser. BROWSER By default, the system sends SMS text message to the first available administrator in case of input alarm.
  • Page 35: Disabling And Enabling Inputs

    14.2. Disabling and Enabling Inputs By default, all inputs are enabled. Once disabled, input alarm event will no longer be followed by an SMS text message. To disable/enable an individual input, please refer to the following configuration methods. SMS text message content: ssss_Zn:OFF Disable input Value: ssss –...
  • Page 36: System Information. Info Sms

    15. SYSTEM INFORMATION. INFO SMS The system supports an informational SMS text message identified as the Info SMS, which can be delivered upon request. Once requested, the system will reply with Info SMS that provides the following: • System date & time. • GSM signal strength.
  • Page 37: System Notifications

    16. SYSTEM NOTIFICATIONS In case of a certain event, the system attempts to send an SMS text message to the first preset administrator phone number only. If the administrator phone number is unavailable and the system fails to receive the SMS delivery report within 20 seconds, it will attempt to send the SMS text message to the next preset administrator phone number.
  • Page 38: Remote System Restart

    SMS text message content: ssss_SETGPRS:PSW:password Set password Value: ssss – 4-digit SMS password; password – up to 31 character password provided by the GSM operator. Example: 1111_SETGPRS:PSW:mobilepsw Config This operation may be carried out from the PC using the GS-Configurator software. Tool This operation may be remotely carried out from the PC using the web browser.
  • Page 39: Technical Support

    For product warranty repair service please , contact your local retail store where this product was purchased. If your problem could not be fixed by the self-guide above, please contact your local distributor. More up to date information about your device and other products can be found at the manufacturer’s website www.entrya.eu 19.2. Restoring Default Parameters 1.
  • Page 40 It is not allowed to copy and distribute information in this document or pass the information to a third party without advanced written authori zation by Entrya Technologies BVBA. Entrya Technologies BVBA reserves the right to update or modify this document and/or related products without a warning.