Advertisement

B
e
n
Q
S
o
l
a
B
e
n
Q
S
o
l
a
I
n
s
t
a
l
l
a
t
i
o
n
I
n
s
t
a
l
l
a
t
i
o
n
(
I
E
C
,
E
T
L
)
(
I
E
C
,
E
T
L
)
Mono
Mono 48 cells series
48 cells series
Mono
Mono
48 cells series
48 cells series
Poly
Poly 60 cells
60 cells series
series
Poly
Poly
60 cells
60 cells
series
series
Mono
Mono 60 cells series
60 cells series
Mono
Mono
60 cells series
60 cells series
Mono
Mo
no 60 cells with light weight series
60 cells with light weight series
Mo
Mo
no no
60 cells with light weight series
60 cells with light weight series
Poly
Poly 72 cells series
72 cells series
Poly
Poly
72 cells series
72 cells series
Back contact 96 cells series
Back contact 96 cells series
Back contact 96 cells series
Back contact 96 cells series
Version 2.0
Version 2.0
Version 2.0
Version 2.0
Note: The content of this manual is subject to change without notice.
© 2014 AU Optronics All Rights Reserved
r
P
h
o
t
o
v
o
r
P
h
o
t
o
v
o
G
u
i
d
e
G
u
i
d
e
l
t
a
i
c
M
o
d
u
l
t
a
i
c
M
o
d
u
PM200M0
PM200M00 0 0 0 / / / / PM048M00
PM200M0
PM200M0
PM245P00 / PM245P03 / PM060P00
PM245P00
/ PM245P03 / PM060P00
PM245P00
PM245P00
/ PM245P03 / PM060P00
/ PM245P03 / PM060P00
PM250M01
PM250M01 / PM060M02
/ PM060M02
PM250M01
PM250M01
/ PM060M02
/ PM060M02
PM060M01
PM060M01
PM060M01
PM060M01
PM072P00
PM072P00
PM072P00
PM072P00
PM096B00 / PM096B01
PM096B00 / PM096B01
PM096B00 / PM096B01
PM096B00 / PM096B01
l
e
s
l
e
s
PM048M00
PM048M00
PM048M00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PM048M00 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BenQ PM048M00 Series

  • Page 1 Mono Mono 48 cells series 48 cells series PM200M0 PM200M00 0 0 0 / / / / PM048M00 PM048M00 Mono Mono 48 cells series 48 cells series PM200M0 PM200M0 PM048M00 PM048M00 Poly Poly 60 cells 60 cells series series PM245P00 / PM245P03 / PM060P00 PM245P00 / PM245P03 / PM060P00 Poly...
  • Page 2: Table Of Contents

    3.2 Mounting with Clamps ........................11 Chapter 4 Wiring, Connecting a Chapter 4 Wiring, Connecting a Chapter 4 Wiring, Connecting a Chapter 4 Wiring, Connecting and Grounding BenQ Modules nd Grounding BenQ Modules nd Grounding BenQ Modules nd Grounding BenQ Modules........
  • Page 3: Chapter 1 General Information

    Always observe Industry Best Practices when handling, installing, and using this product. This guide is designed for use by trained and certified solar professionals only. BenQ Solar does not assume responsibility for loss, damage or expense resulting from installation,...
  • Page 4: Guidelines For Safe Handling And Installation

    In addition to the applicable rules and regulations, please follow all guidelines for safe handling and/or installation of BenQ Solar modules. As always observe industry best practices when handling and/or installing any BenQ Solar module. Save this Installation Guide for future reference.
  • Page 5 Please use caution when handling or connecting any module. Remove all metallic jewelry prior to installing this product to reduce the chance of accidental exposure to live circuits. Use properly insulated tools to reduce your risk of electric shock. During installation use suitable protection prevent a discharge of at least 30 direct current volts to each person on crew.
  • Page 6 STORAGE STORAGE STORAGE STORAGE When storing modules for any period of time, cover modules to ensure protection from the elements. Take special steps to cover/protect the module connectors.. When storing the modules, turn so that the glass is face down. Do not allow water or dust to collect inside module, this can damage module connectors.
  • Page 7: Chapter 2 Benq Solar Module Specifications Chapter 2 Benq Solar Module Specifications

    BenQ Solar Module Specifications The module electrical ratings are measured under Standard Test Conditions (STC) of 1000W/m2 irradiance with AM 1.5G spectrum and a cell temperature of 25ºC. BenQ Solar modules electrical characteristics depend on module Series and Wattage. Please refer to the tables below to learn more about the characteristics of your module(s).
  • Page 8: Pm245P00 Series

    PM048M00 Power 210W 215W 220W 225W 230W 235W 240W Efficiency 16.2% 16.6% 17.0% 17.4% 17.8% 18.1% 18.5% Vmp (V) 24.3 24.4 24.5 25.0 25.1 25.15 25.23 Imp (A) 8.65 8.82 8.99 9.00 9.17 9.34 9.52 Voc (V) 30.6 30.7 30.8 31.8 32.4 32.7...
  • Page 9: Pm250M01/ Pm060M02 Series

    2.5 PM250M01/ PM060M02 Series Module Dimensions (L x W x H): Module Dimensions (L x W x H): Module Dimensions (L x W x H): Module Dimensions (L x W x H): 1639 x 983 x 40 mm (64.52 x 38.7 x 1.57 in) Module Weight: Module Weight: 18.5 kg (41.1 lbs) Module Weight:...
  • Page 10: Pm060P00 Series

    2.8 PM060P00 Series Modu Modu Modu Module Dimensions (L x W x H): le Dimensions (L x W x H): le Dimensions (L x W x H): le Dimensions (L x W x H): 1639 x 983 x 40 mm (64.52 x 38.7 x 1.57 in) Module Weight: Module Weight: 18.5 kg (41.1 lbs) Module Weight:...
  • Page 11: Chapter 3 Mounting Guidelines Chapter 3 Mounting Guidelines

    Chapter 3 Chapter 3 Chapter 3 Chapter 3 Mounti Mounti Mounti Mounting ng ng ng Guidelines Guidelines Guidelines Guidelines Modules may be mounted at any angle from horizontal to vertical. Select the appropriate orientation to maximize sunlight exposure. A gap between the module and system structure or ground is required to prevent wire damage and to allow air to circulate behind the module.
  • Page 12: Mounting With Clamps

    5400 Pa design strength. 3.2 Mounting with Clamps • Clips and clamps are not provided by BenQ Solar. • The clamping clips on the side frame must be in parallel – equidistant from the closest module frame corner (see Figure 1).
  • Page 13 Figure Figure 2 2 2 2 Long rail mounting clamp zone (D1 and D2) Figure Figure Figure Figure 3 3 3 3 Short rail mounting clamp zone (D3 and D4) Figure Figure...
  • Page 14 Long Rail (5400 Pa) Long Rail (5400 Pa) Short Rail (2400 Pa) Short Rail (2400 Pa) Long Rail (5400 Pa) Long Rail (5400 Pa) Short Rail (2400 Pa) Short Rail (2400 Pa) Model Name Model Name Model Name Model Name PM048M00 PM048M00 PM048M00...
  • Page 15 PM072P00 072P00 072P00 Module Clamp Location Details 072P00 Module Clamp Location Details Module Clamp Location Details Module Clamp Location Details Long rail Long rail clamping for 5400 Pa design strength: clamp between D1 – – – – 127 127 mm mm (5.0 in) (5.0 in) Long rail...
  • Page 16: Chapter 4 Wiring, Connecting A Chapter 4 Wiring, Connecting And Grounding Benq Modules Nd Grounding Benq Modules Nd Grounding Benq Modules

    Wiring, Connecting , Connecting , Connecting and Grounding , Connecting and Grounding and Grounding and Grounding BenQ Modules BenQ Modules BenQ Modules BenQ Modules 4.1 Wiring & Connecting DO NOT make any change to the cable or Junction Box. DO NOT disconnect DC Cables alone, someone should always be nearby! DO NOT disconnect/connect modules while they are under load! DO NOT assemble the connector with wet or dirty hands.
  • Page 17 • The DC conductors must be properly gauged so that the voltage drop does not exceed 2% of the nominal voltage. • BenQ Solar PV modules are supplied with or without cables, according to where they are ordered. If supplied without cables, it is recommended that cables with cross sections between 4 and 10 mm be used.
  • Page 18: Module Grounding

    Box and connectors. 4.2 Module Grounding BenQ Solar PV modules have a clearly marked grounding hole on each side of the frame for inserting the ground contact. The grounding screw and bolt are usually sold separately from the mounting equipment.
  • Page 19: System Grounding (Negative)

    PM060M02 PM060M02 PM060M02 For optimal performance, BenQ Solar modules should only be used in conjunction with galvanically insulated inverters where the negative (-) polarity of the PV array is connected to ground protected by a fuse. 4.4 System Grounding (Positive)
  • Page 20: System Grounding (Transformerless)

    A series protection fuse of 15A is recommended for each string when module strings are wired in parallel. BenQ Solar recommends the PV conductor, which cross section is 4 mm . External connection boxes can be used to enable greater cable cross section area for long distance transmission.
  • Page 21 Recommended maximum series/parallel module configurations for 1000V inverter. Maximum series = 1000V / Product Voc / 1.25 (safety factor) Example : The Voc of PM200M00_200 is 30.4V,then the maximum series/parallel module configurations for 1000V inverter is 26. Formula 1000V / 30.4V / 1.25 = 26...
  • Page 22: Chapter 5 Maintenance Chapter 5 Maintenance

    BenQ Solar PV modules can withstand snow pressure of 2400 Pa.(UL 1703) Please use soft brush lightly removing snow pileup. Do not try to remove frozen snow...
  • Page 23: Module Cleaning Instructions

    Do not leave stagnant water on glass surface. 5.3 Cleaning the Frame BenQ Solar module frames include an anodic oxide coating to increase produce life. The cleaning cycle for regular anodic oxide coatings is generally every six months.
  • Page 24: Chapter 6 Certificatio

    Chapter 6 Certification 6.1 IEC Certification The PV modules provided by BenQ Solar all pass the design qualification and type approval standard IEC 61215 edition 2. The PV modules provided by BenQ Solar all pass the safety qualification standard IEC 61730 certified for application class A.

Table of Contents