Kastel EASY:FAST Manual

Equipment for potable water treatment

Advertisement

Quick Links

EASY:FAST
MANUAL
EQUIPMENT FOR POTABLE WATER TREATMENT
1
Cod. 2050-0001 Rev 1.1

Advertisement

Table of Contents
loading

Summary of Contents for Kastel EASY:FAST

  • Page 1 EASY:FAST MANUAL EQUIPMENT FOR POTABLE WATER TREATMENT Cod. 2050-0001 Rev 1.1...
  • Page 2 YEAR XXXX IP20 230V MODEL EASY:FAST 50-60 Hz VERSION 180 W SERIAL NO. WATER TEMP. 5-35°C INLET WATER 150-500 kPa MIN/MAX PRESSURE MIN/MAX MADE IN ITALY WARNING: THIS EQUIPMENT NEEDS A REGULAR PERIODIC MAINTENANCE TO ENSURE THE POTABILITY REQUIREMENTS OF TREATED DRINKING WATER AND THE MAINTENANCE OF IMPROVEMENTS AS DECLARED BY THE MANUFACTURER.
  • Page 3: Table Of Contents

    INDEX GENERAL INFORMATION ......................... 4 MANUFACTURER / ASSISTANCE ..................... 4 CERTIFICATIONS ........................4 PURPOSE AND CONTENTS ......................4 CARE AND STORAGE OF THE MANUAL ..................... 4 IMPORTANT SYMBOLS TO REMEMBER ....................4 FEATURES OF THE EQUIPMENT ......................5 RECOMMENDED USE ........................5 FORBIDDEN USE ........................
  • Page 4: General Information

    BUILDER ASSISTENCE ARISTARCO Spa Personal Data of the Retail Seller Castelfranco Veneto (TV) CERTIFICATIONS EASY:FAST was manufactured in compliance with the following EU Directives: Machines 2006 / 42 / UE Low Voltage 2014 / 35 / UE Electromagnetic Compliance 2014 / 30 / UE...
  • Page 5: Features Of The Equipment

    FEATURES OF THE EQUIPMENT RECOMMENDED USE EASY:FAST is equipment able to modify organoleptic and chemical characteristics of potable water, reducing saline content. It can be installed in home and in work place. It can be used for the production of osmotic water for commercial and HO.RE.CA applications.
  • Page 6: Technical Specifications

    TECHNICAL SPECIFICATIONS EASY:FAST TECHNICAL SPECIFICATIONS Height x Width x Depth (mm) 168x515x476 Weight (kg) Approved Decibel Level under normal operating <70 conditions (db) Membranes (nr. 4) TWB2A1 Carbon Block filter Profine® BLUE small WATER SUPPLY SPECIFICATIONS Water quality Drinkable Minimum water temperature (°C) Maximum water temperature (°C)**...
  • Page 7: General Dimensions

    GENERAL DIMENSIONS INNER LAYOUT 1. By-pass valve and mix 9. PROFINE® BLUE SMALL filter 2. Inlet solenoid valve 10. PROFINE® head 3. Maximal pressure switch 11. Electronic board 4. Minimal pressure switch 12. Pump 5. Permeate block 6. Membranes 7. Expansion tank 8.
  • Page 8: Installation

    INSTALLATION WARNING Equipment installation must be performed by qualified technical personnel; detailed instructions for installation are in the “Technical Manual ". User should not perform equipment installation. The room in which the appliance is installed must have a floor drain to prevent damage to persons or property in case of flooding.
  • Page 9: Drain Bracket Installation

    DRAIN BRACKET INSTALLATION Install the drain bracket on the 40mm diam. sink drain siphon. Check that the seal rests properly on the pipe and the bolts are tight. Remove the nut of the drain. By using a 2 mm drill bit, drill a hole in the exhaust pipe of the siphon, at the nut just disassembled.
  • Page 10: Exchange Of The Capillary

    EXCHANGE OF THE CAPILLARY °F <11 12--25 26--35 36--44 HARDNESS °Dh <5 6--15 16--20 21--25 WARNING After replacing the capillary, set the filter change time in the control unit (§ 4.8). WARNING BLUE CAPILLARY = recovery 55-60% at 15°C BLACK CAPILLARY = recovery 35-40% at 15°C (softener recommended) (standard) WHITE CAPILLARY = recovery 25-30% a 15°C (softener recommended) SOFTENER = softener or required antiscalant dosing The equipment must not be installed with inlet water>...
  • Page 11: Functioning

    FUNCTIONING FIRST START-UP WARNING The first start-up of the machine must be done by the installer. The installer checks the correct functioning of the machine. Insert the power plug in a grounded socket 230V 50Hz; the machine is ready to operate. It is recommended to let the water run for at least an half of hour, to drain out the substances for the preservation of the membranes.
  • Page 12: Electronic Board Functioning

    ELECTRONIC BOARD FUNCTIONING When the board is in normal operating mode, the name of EASY:FAS uS/cm the equipment or of the dealer is displayed. 0050 Pressing the key the instantaneous conductivity is displayed. With board in standby mode, you can scroll the menu with ;...
  • Page 13: Configuration Menu

    CONFIGURATION MENU In order to have access to the programming pages, the key while you connec the supply plug. Setting Press > Subsequently the board will require pressing the key to confirm access to the programming. The first page allows to reset the hour counter by pressing Reset Press >...
  • Page 14: Ordinary Maintenance

    ORDINARY MAINTENANCE REQUIRED TRAINING FOR MAINTENANCE TECHNICIANS Maintenance personnel must possess the following qualifications as prescribed in this manual:  The required technical knowledge to understand the concepts outlined in this manual.  Knowledge of basic hygiene  General familiarity with the device, in addition to a basic knowledge of troubleshooting electrical and hydraulic problems.
  • Page 15: Replacement Of Cartridge Profine Filter

    REPLACEMENT OF CARTRIDGE PROFINE FILTER WARNING The equipment must be accompanied by external pre-filter that can guarantee dechlorination and filtration of raw water. It’s recommended to use the filter PROFINE® BLUE Small To replace the pre-filter follow these steps: Turn off the machine by pressing the button Turn used up cartridge ¼...
  • Page 16: Preload Of The Expansion Tank

    PRELOAD OF THE EXPANSION TANK For the preload of the expansion tank follow these steps: Disconnect the power supply Empty the expansion tank completely supplying water. With the use of a compressor and a tire gun, bring the tank preload pressure to 0.1 MPa. Put the machine in the original position and connect the power plug.
  • Page 17: Troubleshooting

    TROUBLESHOOTING The operations indicated must only be carried out by qualified personnel, with the exception of those marked *. Problem: The display does not turn on. Cause Solution No electricity supply Make sure the plug is inserted and there is electricity supply. Board in “OFF”...
  • Page 18 Problem: The machine produces little water, the dishwasher indicates alarm. Cause Solution Clogged filter. Check the pressure downstream of the filter, if clogged, replace it. Damaged pump. Disconnect the plug, open totally the MIX valve and contact service. Clogged Membranes. Disconnect the plug, open totally the MIX valve and contact service.
  • Page 19: Disposal

    DISPOSAL If disposed of privately, exhausted filters and membranes are to be considered not dangerous solid waste. (CER 15.02.03 or 16.02.16) If intended as a replacement, subject to periodic replacement. If disposed of by companies, the filters are CER 19.09.04, the membranes CER 15.02.03. At the end of the lifetime, the equipment must be disposed of at an authorized dismantling and disposal center (CER 20.01.36).
  • Page 20: Attachment I - Ue Declaration

    ATTACHMENT I – UE Declaration 1. Equipment/Product Model EASY:FAST 2. Name and address of the manufacturer or his authorized representative: KASTEL Castelfranco Veneto (TV) 3. This declaration of conformity is issued under the sole responsibility of the manufacturer. 4. Aim of the declaration: Production year 2017 and subsequent 5.
  • Page 21: Attachment Ii - Maintenance Log

    ATTACHMENT II – MAINTENANCE LOG INSTALLATION TECHNICIAN TECHNICIAN TECHNICIAN REGULAR MAINTENANCE TECHNICIAN TECHNICIAN TECHNICIAN Cod. 2050-0001 Rev 1.1...