10.3. P.C.B. (Printed Circuit Board) exchange
10.3.1. Caution
1. To remove P.C.B. , wait 1 minute after power was off for discharge from electrolysis capacitors.
10.3.2. Quick adjustment after P.C.B. exchange
P.C.B.
P Board
Vsus
SC Board
Vad
SS Board
Ve
*See the Panel label.

10.4. Adjustment Volume Location

10.5. Test Point Location

Name
Test Point
TPVSUS (SS)
TPVAD (SC)
TPVE (SS)
Voltage
Volume
Vsus ± 2V
VR351 (P)
-90V ± 1V
VR6801(SC)
Ve ± 1V
VR6250 (SS)
37