    TABLE OF CONTENTS MASS FILTER INSTRUCTIONS 1. PACKAGING COMPONENTS REQUIREMENTS FOR PROPER INSTALLATION 2. BEFORE CONNECTING THE FILTER 2.1. LOCATION 3. TOP SELECTOR VALVE 4. OPERATION 4.1. PRIMING THE FILTER 4.2. FILTRATION 4.3. FILTER BACKWASHING 4.4 DRAINING THE POOL 4.5. RINSING 4.6. RECIRCULATION (ONLY PERFORMED BY A 6-WAY VALVE) 5. CABLE REPLACEMENT 6. MAINTENANCE 7. TROUBLE-SHOOTING AND TECHNICAL ASSISTANCE GUARANTEE CERTIFICATE 1.
  • Page 3: Mass Filter Instructions

    MASS FILTER INSTRUCTIONS The manual can be downloaded as a PDF file from the website: www.rexnordic.uk Read this manual carefully and keep it in a safe place for future reference. This manual covers the filtration unit that is described (name and reference) in the attached document “TECHNICAL CARACTER- ISTICS”.
  • Page 4: Requirements For Proper Installation

    During the installation process, if in doubt, contact the vendor of the unit. 2.2. ASSEMBLY Once the unit is in place, proceed as follows: (See pages 10 to 14). Attach filter to the mass filter according to model (Ø300-Pag. 10-14). Fix the pump to the base with the screws and washers supplied.
  • Page 5: Top Selector Valve

    3. TOP SELECTOR VALVE VALVE TYPES AND FUNCTIONING A 5-way valve: The selector valve on top of the filter is used to select the 5 different filter modes: filtration, backwashing, rining, draining and closed. B 6-way valve: This valve has the same mode as the 5-way valve plus a recirculation mode. To vary the position of the valve, proceed as follows: •...
  • Page 6: Filtration

    4.2. FILTRATION NEVER HANDLE THE VALVE WHILE THE MOTOR IS RUNNING. Backwash the sand before the first filtration. (Part 5.3) The valve should be in the filter position (FILTER). The service life of the filter will be longer if the periods of continuous oper- ation do not exceed 4 hours.
  • Page 7: Cable Replacement

    5. CABLE REPLACEMENT If the power cable becomes damaged, it must be replaced by the manufacturer, your after-sales service engineer or a similarly qualified person in order to avoid hazards. 6. MAINTENANCE After the bathing season has ended, the filter should be kept in a dry place where it is protected from bad weather. After per- forming a final backwash to clean the silica sand, dismantle the hoses and drain the water in the filter through the tank drain plug until it is completely empty.
  • Page 8 PROBLEM CAUSE SOLUTION Water leakage. Check the reason for water loss. Ensure that the clamps and terminals are in the correct position and have been tightened. If the water loss continues, contact the pool manufacturer’s after-sales service. After the filter has started up, there is The valve is not in the “filter”...
  • Page 9 - Images of the products are exemplary. Ø300 mm Only in some models Metallic clamp 5 functions valve Connection hose Ø38 Pressure gauge set Closing band assembly Screw M8x30 DIN933 Collector filter assembly Washer M8 DIN125 Filter body Filter purgue assembly Pump Mass filter base...
  • Page 10 1 - Ø300 mm - Images of the products are exemplary. 2 - Ø300 mm...
  • Page 11 3 - Ø300 mm 4 - Ø300 mm RETURN PUMP...
  • Page 12 5 - Ø300 mm - Installing the pressure gauge 6 - Ø300 mm - Installing the pump hose...
  • Page 13 Figures FIG. 1 FIG. 2 CAUTION FIG. 3 FIG. 4 PUMP WRONG PUMP CLAMP...
  • Page 14 Figures FIG. 4A PLACE THE CLAMP FOLLOWING Keep the same distance THE FILTER when tightening the screws TANK LINE WRONG SKIMMER FIG. 5 RETURN INLET FIG. 6 PUMP PUMP...
  • Page 15 GUARANTEE CERTIFICATE 1. GENERAL TERMS 1.1. In accordance with this provisions, the seller guarantees that the Rex Nordic Product corresponding to this guarantee (“The Product”) doesn’t have any default in conformity at this time of delivery. 1.2. The guarantee term for the product is two (2) years and will be calculate from the date of delivery to the purchaser. 1.3.
  • Page 16 EVIDENCE OF CONFORMITY • The products listed above are in compliance with the safety prescriptions: • 2006/42/EC Machine Directive Safety prescriptions • 2014/35/EU Low voltage directive • 2000/14/EC Noise émission directive • 2015/863/EU modify Annex II of 2011/65/EU • EN 60335-1:2012/A11:2014. • EN 60335-2-41:2003/A2:2010.
  • Page 17 TECHNICAL CARACTERISTICS Ø Filter Ø300 Flow 3,5m3/h Sand filling ± 25 KG Grain Size 0,4 - 0,8 mm Filtration speed 50m3 / m2 / h Power 1/3 CV Voltage 230V 50Hz 09443-0008 / Rev. 00 - We reserve the right to change all or part of the features of the articles or contents of this document, without prior notice.
  • Page 18 Technical support and service North UK Service I +44 7538 959 818 South UK Service I +44 75 3895 9836 Customer Support I 013 553 773 70 service@rexnordic.com...