THT8 TABLE OF CONTENTS PRECAUTIONS AND SAFETY MEASURES ............... 2 1.1 During use ......................... 2 GENERAL DESCRIPTION ................... 3 PREPARATION FOR USE ................... 3 3.1 Initial checks ........................3 3.2 Powering the instrument ....................3 ...
THT8 1 PRECAUTIONS AND SAFETY MEASURES The instrument has been designed in accordance with the directives on electronic measuring instruments. For your safety and to avoid damaging the instrument, please follow the procedures described in this manual and read with particular care all the notes preceded by the symbol .
THT8 2 GENERAL DESCRIPTION The THT8 instrument is an extremely small professional digital camera capable of carrying out infrared temperature measurements directly connected to a mobile device (Android smartphones only) via integrated USB-C output. Image viewing and instrument management is only possible via 'HTSmartCamera APP ‘downloadable and installable on your mobile device.
Fig. 1: Description of the instrument 5 USE OF HTSMARTCAMERA APP The THT8 camera is managed only in combination with the HTSmartCamera APP available only for Android systems freely downloadable from the relative Store (frame the relative QR code below).
The screen of Fig. 2 – central part indicating the unconnected thermal imaging camera is shown 3. Connect the THT8 thermal imaging camera to the mobile device via the USB-C output (see Fig. 1 – Part 1). The recognition of the instrument is automatic by the mobile device 4.
THT8 MAIN SCREEN CAPTION: 1. Mobile device flashlight 2. Advanced analytics tools 3. Manual instrument calibration 4. General menu 5. Image mirror function 6. Temperatures hot spots, cold and central slider 7. Temperature measurement units 8. Maximum temperature associated with the palette 9.
THT8 GENERAL MENU 1. Tap the icon to enter the general menu of the application. The screen of Fig. 4 – left side is shown on display Fig. 4: General menu Icon Description Tap this icon to show the main screen of the application Tap this icon to enter the Gallery of Saved IR Images/Videos (see §...
Page 9
THT8 Fig. 5: Visualization of settings section Temperature Settings allows you to select the display of the sliders associated with the temperature measurement of the "hot" point, the "cold" point and the central cursor of the image (see Fig. 6) Fig.
THT8 ADVANCED ANALYSIS SECTION CAPTION: 1. Object temperature information on image 2. Line on Image object 3. Area object on image 4. Point object on image 5. Manual instrument calibration 6. Added Point on image 7. Deleting all objects on the image 8.
THT8 COLOR PALETTES 1. Tap the icon to select the color palette to associate with the IR image on your mobile device's display. The following screen is shown Fig. 8: Display of color palettes 2. Select by dragging the desired color palette from the 9 possible options available. The...
THT8 SAVING IMAGES AND VIDEOS The application allows you to save images (snapshots) in JPG format and IR videos in MP4 format that can be called up from the Gallery (see Fig. 3 – part 15). 1. Tap the white center icon (see Fig. 3 – part 17) to save the image on the display. The message "Saved photo"...
Page 13
THT8 Fig. 10: Selection of images/videos in the Gallery 6. Select the icons of the images/videos you want to delete. Tap on the icon to perform the operation or "Cancel" to return to the previous screen EN - 12...
THT8 EDIT IMAGES AND CREATING REPORT The application allows you to edit an image saved in the gallery (change palette and add objects) and create a PDF report with the inclusion of a visible image selected by the user. Edit saved image 1.
Page 15
THT8 PDF Reporting 1. Enter the Gallery and select the desired image (see § 5.7) as shown in Fig. 11 – right side 2. Tap the icon to create the PDF report associated with the selected image. The screen of Fig. 12 – left side is shown on display. Confirm with "OK" to start the operation 3.
Page 16
THT8 Fig. 13: Visualization of PDF report EN - 15...
THT8 6 MAINTENANCE GENERAL During use and storage comply with the recommendations listed in this manual to avoid possible damage or danger during use. Do not use the tool in rooms with high humidity or high temperature. Do not expose directly to sunlight. Always turn off the tool after use.
THT8 8 ASSISTANCE WARRANTY CONDITIONS This tool is guaranteed against any defect in material and workmanship, in accordance with the general conditions of sale. During the warranty period, defective parts can be replaced, but the manufacturer reserves the right to repair or replace the product. If the instrument is to be returned to the after-sales service or to a retailer, the transport is charged to the Customer.