Download Print this page

LG 24MP59HT Service Manual page 11

Hide thumbs Also See for 24MP59HT:

Advertisement

Check whether written EDID data is correct or not.
(refer to Product spec).
 After writing EDID, send Elapsed Time Clear command.
(Elapsed time should not be displayed, after EDID writing)
-
: Confirm periodically (in the first set of new lot, process change) whether module name and
aging time disappeared on the self-diagnostics OSD with signal cable disconnected.
 If Elapsed Time Clear command isn't executed, module name, aging time and TCO word appear
on the self-diagnostics OSD.(Module name and aging time should not appear after writing EDID)
 Make sure to do FACTORY RESET at the final process.
3.2.5.9 V-Com Adjustment
*LGD panel biz need adjusting V-COM by software
Definition: adjusting V-Com level thereby show minimum flicker
Process: By LG cmd , Check Flicker Level and If Can't meet Flicker spec,
Adjust V-com value through IIC line of panel. If flicker level meet spec, save V-com value at
EEPROM.
Connection Diagram
The type of Probe must be
V-com adjustment Spec
27MP59HT/24MP59HT
Flicker level
≤ 35
3.2.6.0. Shipping condition
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Energy saving
: low
CA-P12/15 or CA-P15
- 11 -
LGE Internal Use Only

Advertisement

loading

This manual is also suitable for:

24mp59htp