Download Print this page

Kennedy MTW011 Operating Instructions page 2

Advertisement

MECHANIC'S
TORQUE
WRENCHES
SPECIFICATIONS
Order Code
Sq.
Torque Range
Model
KEN-557 Drive
N.m
kgf.m
lbf.ft
lbf.in
MTW011 -3500K
" 2.5 - 11 0.25 - 1.12 1.84 - 8.11
22 - 97
3/ 8
MTW033 -3521L
3/ 8
"
7 - 33
0.7 - 3.4
5 - 24
60 - 300
MTW068 -3541L
" 14 - 68
1.4 - 7
10 - 50
125 - 600 1070mm 7.58kg
3/ 4
MTW135 -3560K
1/ 2
" 25 - 135 2.5 - 13.7 18.4 - 99.5 220 - 1194 556mm 1.6kg
MTW225 -3580K
" 50 - 225 5.0 - 22.9 36.8 - 166 441 - 1992 600mm 2.3kg
1/ 2
MTW330 -3600K
1/ 2
" 70 - 330 7.1- 33.6 51.6 - 243 619 - 2920 805mm 2.6kg
MTW810 -3610K
" 200 - 800 20.3 - 81.5 147 - 590 1770 - 7080 1070mm 7.58kg
3/ 4
INSTRUCTIONS FOR USE
HAND POSITION FOR APPLYING TORQUE
When applying torque the wrench must be held in the
correct position on the handle as this affects the reading.
SETTING TORQUE LEVEL
Overall Weight
Length
338mm 0.63kg
425mm 0.72kg
SAFETY AND MAINTENANCE
You have purchased a quality product that is designed
for high performance and a long service life. If safety
and maintenance procedures are followed and the tool is
used correctly it will last for many years.
Always follow instructions for assembly before
operation.
Ensure your workpiece is firmly held or fixed before
commencing work.
When using torque tools it is possible that
fasteners may break or slip. Always stand with
both feet on the floor and avoid applying torque in
awkward positions.
The drive part of the tool and any accessories
should always be in line with the fastener.
Misalignment and uncontrolled movement will
Square
affect accuracy.
Head
Only use the tool on the job for which it has been
designed.
Keep the tool clean by wiping. Never dip in
cleaning fluid.
Always store tools away from dirt, oil and swarf as
Torque
this can damage mechanisms.
Setting
We recommend that your torque tool be calibrated
Scale
annually.
The torque wrench is lubricated for life and should not
Handle
be oiled. The only exception is the ratchet head which
Torque
may be lubricated for smooth operation.
Setting
Do not drop or throw the wrench.
Lever
After use adjust to the lowest torque setting and
clean and store in a safe, dry place.
All KENNEDY tools are supplied with a calibration
certificate valid for 12 months from date of purchase.
(Please retain invoice as proof of purchase).
Re-Calibration is available through
your local Distributor.
KENNEDY Torque Wrenches are manufactured and
tested to ISO 6789-2:2017
Accuracy = ± 4% of the set load.

Advertisement

loading

This manual is also suitable for:

Mtw033Mtw068Mtw135Mtw225Mtw330Mtw810 ... Show all