Power safety kit

Advertisement

Quick Links

AT-SWH-000
Power Safety Kit
Quick Installation Guide
Model Name
Supported Models
Feature
Operating Temperature
Approvals
Weight
Dimensions
Included Accessories
AT-SWH-000
AT-CAB-001, AT-CAS-001
Suitable for VIVOTEK AT-CAB-001 or AT-CAS-001 Cabinet Surge protection
Fuse
Alarm-door switch
MCB fuse: -40 °C ~ 75 °C (-40°F ~ 167°F) Surge protector: -40 °C ~ 80 °C (-40°
F ~ 1 76°F) Door switch: -40 °C ~ 85 °C (-40°F ~ 185°F)
MCB fuse: IEC/EN 60898-1, IEC/EN 60947-2, UL 1077 Surge protector: IEC 61643-1 1 /
EN 61643-1 1
Door switch: EN 61058, UL 61058
MCB fuse: 1 25 g Surge protector:
240g Door switch: 10 g
MCB fuse: 88x1 7 .5x69 mm
Surge protector: 95x35.6x58 mm
Terminal block 4x2.5 mm² (Gray): 72.6x5.1x35.5 mm Terminal block 4x2.5 mm² (Yellow/Green):
72.6x5.1x35.5 mm Terminal block 2x4 mm² (Yellow/Green): 57x6.1x35.5 mm Door switch:
41x10x30 mm
Door switch cable: 300 mm
Screw: 75 mm
MCB fuse, surge protector type 2, terminal block 4x2.5 mm²
(gray), terminal block 4x2.5 mm² (yellow/green), terminal block
2x4 mm² (yellow/green), door switch, door switch cable, screw

Advertisement

loading

Summary of Contents for Vivotek AT-SWH-000

  • Page 1 Model Name AT-SWH-000 Supported Models AT-CAB-001, AT-CAS-001 Feature Suitable for VIVOTEK AT-CAB-001 or AT-CAS-001 Cabinet Surge protection Fuse Alarm-door switch MCB fuse: -40 °C ~ 75 °C (-40°F ~ 167°F) Surge protector: -40 °C ~ 80 °C (-40° Operating Temperature F ~ 1 76°F) Door switch: -40 °C ~ 85 °C (-40°F ~ 185°F)
  • Page 2: Wiring And Connections

    Wiring and connections If you install 3/4 "and M16 cable glands and conduit to protect properly installed cables and outside wiring, water can from the cabinet. Install the cable glands correctly so that the IP rating of the product is maintained. If not seep into the cabinet and damage the devices inside.
  • Page 3 Line Neutral Terminal block Earth) External ground Line Neutr or land Cable gauge: TO solid wire, 2.5 to 25 mm trace length: 12.5mm Conductor cross section (top / bottom): solid wire, 35 mm 2; Flexible, 25 mm 2 14 - 4 AWG Surge protector: Circuit breaker: Busbar cross section (top / bottom): 10 mm 2;...
  • Page 4 Below is a sample connection drawing showing the use of a 120V or 240V DC power supply and connection to a safety kit. FG (green / yellow) - V (black) Power supply AC / L (brown) + V (red) AC / N (blue) DC output AC / N AC / L...
  • Page 5 a web console with the camera on Settings> Event> Event settings. please refer to documentation that I arrive with your camera. DI1 + DI- GND Camera ground connection Connect a ground wire to the screws near the safety wire.