Series 5001 Single Row 3-Inch Pole Top
Parts List
Part
SolarMount rail
Cross pipe
Pole clamp
Pole cap
7
Hexhead bolt,
⁄
˝
16
7
Lock washer,
⁄
˝
16
7
Nut,
⁄
˝
16
Saddle
3
U-bolt,
⁄
˝
8
3
Flange nut,
⁄
˝
8
Module mounting clip
1
Module bolt,
⁄
˝
4
1
Flange nut,
⁄
˝
4
Note: Parts are illustrated in exploded views (pp. 2–4).
*Per module to be mounted. Series 5001 racks include clips and hardware to mount 2 to 6 modules.
UniRac welcomes input concerning the accuracy and user friendliness of
this manual. Please write to publications@unirac.com.
with SolarMount™ HD Rails
Installation Manual 524
U.S. and other patents pending.
Wrench
Qty.
size
2
1
2
1
5
4
⁄
˝
8
4
9
4
⁄
˝
16
2
2
9
4
⁄
˝
16
4*
7
4*
⁄
˝
16
7
4*
⁄
˝
16
Thank you for purchasing a UniRac. Please review this
manual com plete ly before proceeding.
This rack is intended for a 3-inch Schedule 40 steel
pole (O.D. 3
Assembly order is not critical. Work from the pole
outward or attach PV modules to rails before mount-
ing the array to the pole.
The installer is solely re spon si ble for:
• complying with all applicable building
codes, including any that supercede these
instructions;
• pole installation appropriate to local wind and
soil conditions;
• using only UniRac parts and installer-supplied
parts as specifi ed by UniRac (substitution of
parts will void the warranty);
• installing all electrical aspects of the PV array.
Recommended
torque (ft-lbs)
Caution
Stainless steel hardware can seize up, a process
called galling. To sig nifi cant ly reduce the like li hood
30
of galling, apply a small drop of anti-seize lubricant
to the threads of all bolts before installation.
30
Anti-seize lubricants are readily available in auto
parts and hardware stores. In their absence, any
lubricant will reduce chances of galling.
30
15
15
Pub 040625-3ii