Advertisement

Quick Links

LuchsNT RGB / LED
Operator´s Manual
GB
Translation of the original

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the fluvo LuchsNT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmalenberger fluvo LuchsNT

  • Page 1 LuchsNT RGB / LED Operator´s Manual Translation of the original...
  • Page 2: Table Of Contents

    Spotlights – LED control unit connecting cable ............19 Technical data ....................20 Technical specification ....................20 Dimensions ....................... 21 Device installation ..................... 22 Type plate ......................... 23 Guarantee seal ......................23 Subject to technical changes Schmalenberger GmbH + Co. KG LuchsNT D-72072 Tübingen / Germany Version: 27142-A.1...
  • Page 3: Introduction

    The LuchsNT spotlights must only be operated with the control unit designed for it by the manufacturer. Subject to technical changes LuchsNT Schmalenberger GmbH + Co. KG Version: 27142-A.1 D-72072 Tübingen / Germany...
  • Page 4: Packaging Contents

    Packaging contents  Control input  Jumper at control terminal  Operator’s Manual Subject to technical changes Schmalenberger GmbH + Co. KG LuchsNT D-72072 Tübingen / Germany Version: 27142-A.1...
  • Page 5: Functional Features

    LED + and LED – are disconnected via a relay. If the spotlights are switched ON, a relay switches the voltage back to the output terminal. Subject to technical changes LuchsNT Schmalenberger GmbH + Co. KG Version: 27142-A.1 D-72072 Tübingen / Germany...
  • Page 6: Connections And Adjusters

    Notice: Rotary and dip switches 12 and 13 are read in once when the device is started. A change of switch positions during operation is therefore not accepted until the next device start. Subject to technical changes Schmalenberger GmbH + Co. KG LuchsNT D-72072 Tübingen / Germany Version: 27142-A.1...
  • Page 7: Terminal Compartment Disconnection

    Trip characteristic C: for 6 control units Spotlights connection area Screw terminals for wire cross-section 0.2 to 2.5 mm² 4 pin: connection 2xLED+ 2xLED- Subject to technical changes LuchsNT Schmalenberger GmbH + Co. KG Version: 27142-A.1 D-72072 Tübingen / Germany...
  • Page 8: Configuration Via Dip Switch

    Position 6 defines the BUS communication with the converter box via terminal connection 4. Function Pos.6 Note BUS Master Control unit with converter box 3.0 BUS Slave Normal operation Subject to technical changes Schmalenberger GmbH + Co. KG LuchsNT D-72072 Tübingen / Germany Version: 27142-A.1...
  • Page 9: Analog" Control Terminal

    For the bus installation, shielded cables twisted in pairs must be used. E.g. CAT6 network cable  Ensure that the polarity of the bus connection is correct Subject to technical changes LuchsNT Schmalenberger GmbH + Co. KG Version: 27142-A.1 D-72072 Tübingen / Germany...
  • Page 10: Bus" Control Terminal

    Recommended control line 2 x 0.5 mm² BUS address setting 0x80 0x81 0x82 0x83 0x84 0x85 0x86 0x87 0x88 0x89 0x8A 0x8B 0x8C 0x8D 0x8E 0x8F address Subject to technical changes Schmalenberger GmbH + Co. KG LuchsNT D-72072 Tübingen / Germany Version: 27142-A.1...
  • Page 11: Diag System Diagnosis Button

    2 s as follows:  white + red + green + blue  white  red  green  blue Subject to technical changes LuchsNT Schmalenberger GmbH + Co. KG Version: 27142-A.1 D-72072 Tübingen / Germany...
  • Page 12: Sensor Button Connection Diagram

    Effect of switching: Pulse activated one time Electrical function: normally open / N/O contact Electrical data: = 200 mA / U = 24 V DC Subject to technical changes Schmalenberger GmbH + Co. KG LuchsNT D-72072 Tübingen / Germany Version: 27142-A.1...
  • Page 13: Functional Description

    Notice: Rotary and dip switches 12 and 13 are read in once when the device is started. A change of switch positions during operation is therefore not accepted until the next device start. Subject to technical changes LuchsNT Schmalenberger GmbH + Co. KG Version: 27142-A.1 D-72072 Tübingen / Germany...
  • Page 14: Led Display

    SYNC GND => SYNC GND The terminal groups "IN" and "OUT" are connected in parallel on the printed circuit board and are therefore equivalent. Subject to technical changes Schmalenberger GmbH + Co. KG LuchsNT D-72072 Tübingen / Germany Version: 27142-A.1...
  • Page 15: Individual Control Of The Rgb Spotlights

    Whether a signal is present at the DMX-IN input terminal is visible via the diagnostic LED in the terminal compartment. Subject to technical changes LuchsNT Schmalenberger GmbH + Co. KG Version: 27142-A.1 D-72072 Tübingen / Germany...
  • Page 16: External Sensor Button Via Converter Box 3.0

    The status of the digital outputs DOUT1 to DOUT3 is displayed via the green LEDs in the converter box. The output is then active when the green LED lights up. Subject to technical changes Schmalenberger GmbH + Co. KG LuchsNT D-72072 Tübingen / Germany...
  • Page 17 External buttons via the converter box can also be connected in the synchronous mode of several control units. The connection is made to the SYNC-MASTER device. Subject to technical changes LuchsNT Schmalenberger GmbH + Co. KG Version: 27142-A.1 D-72072 Tübingen / Germany...
  • Page 18: Luchs-Nt Rgb And Led-White Spotlights

     Maximum electrical power per spotlights 33 W The spotlights must only be operated under water  The spotlights is fitted with temperature protection. Subject to technical changes Schmalenberger GmbH + Co. KG LuchsNT D-72072 Tübingen / Germany Version: 27142-A.1...
  • Page 19: Installation Of Luchsnt Lighting Unit

    Cable length >10 m cable cross-section 4.0 mm² Spotlights connecting cable 3 m / 10 m / 20 m with cable cross-section 1.5 mm² Subject to technical changes LuchsNT Schmalenberger GmbH + Co. KG Version: 27142-A.1 D-72072 Tübingen / Germany...
  • Page 20: Technical Data

    Switching threshold for button 10 … 14 V DC LED current max. 30m A DC Display LED – GREEN Operation LED - RED Service Subject to technical changes Schmalenberger GmbH + Co. KG LuchsNT D-72072 Tübingen / Germany Version: 27142-A.1...
  • Page 21: Dimensions

    Cable ø 7-13 mm Cable screw connector Spotlights supply line 2x cable ø 6 mm 6x cable screw connector Control line Cable ø 3.5-7 mm Subject to technical changes LuchsNT Schmalenberger GmbH + Co. KG Version: 27142-A.1 D-72072 Tübingen / Germany...
  • Page 22: Device Installation

    The air intake temperature at the underside of the device must not exceed the values given in the technical data. Optional accessories Adapter plate for DIN rail mounting Subject to technical changes Schmalenberger GmbH + Co. KG LuchsNT D-72072 Tübingen / Germany Version: 27142-A.1...
  • Page 23: Type Plate

    If the guarantee seal is destroyed, the guarantee and manufacturer's warranty shall be rendered null and void. All setting options are located in the freely accessible terminal compartment. Subject to technical changes LuchsNT Schmalenberger GmbH + Co. KG Version: 27142-A.1 D-72072 Tübingen / Germany...
  • Page 24 +49 (0)7071 70 08-0 Schmalenberger GmbH + Co. KG Fax: +49 (0)7071 70 08-14 Strömungstechnologie Internet: www.fluvo.de Im Schelmen 9 – 11 E-mail: info@schmalenberger.de D-72072 Tübingen / Germany © 2019 Schmalenberger GmbH & Co. KG; All rights reserved Manual is subject to changes...

Table of Contents