Humidity measuring unit CMG 100 Content 1.0 Safety information 2.0 Guarantee 3.0 Intended use 4.0 Environmental protection and recycling 5.0 Transportation and packaging 6.0 Operation 7.0 Commissioning 8.0 Use 9.0 Care, cleaning and maintenance 10.0 Scope of delivery 11.0 Technical data 12.0 Air dehumidification...
CLIMIA 1.0 Safety information General safety notes Battery/rechargeable battery Carefully read the operating manual • Handle the product with care. It is • When inserting the battery / before placing the unit in service damaged by bumps, impacts or rechargeable battery, ensure for the first time.
All products are packed for returns the "certificate of guarantee" other building materials. The unit transport in environmentally to Climia Intakt GmbH at the time can be used to check whether the friendly materials. Make a valuable when the units are purchased and...
Humidity measuring unit CMG 100 7.0 Commissioning 8.0 Use • The measuring unit is not suitable Inserting and replacing batteries General notes before starting for measuring metal or other measuring highly conductive materials. The humidity measuring unit is If there is metal enclosed in powered by a 9 V block battery.
Page 8
CLIMIA Press the MEAS key (5) to start If necessary, press the MEAS measuring in a clearly dry area of • • a similar or identical material. If the calibration procedure. The key [5] to freeze a value on the subsequent measurements LC display shows “CA”...
Humidity measuring unit CMG 100 9.0 Care, cleaning and maintenance Setting the signal function Care and cleaning “WET” The value can be set from 50 to 100. The factory default • The measuring unit also displays setting is 60. • Disconnect the product from...
CLIMIA 11.0 Technical data Unit data CMG 100 Power supply 1 x 9 V battery Battery life Hours. Current consumption μA Resolution 1 unit Accuracy ± 1 unit Measuring range 0-100 units Measuring depth 20-40 Screw connection (tripod) mm / Inches 6.3 / 1/4“...
Humidity measuring unit CMG 100 12.0 Air dehumidification The correlations occurring when 1. By heating and air exchange: air is dehumidified are based on physical laws. These are depicted here in graphical The air in the room is heated form in order to provide you with a...
Page 12
CLIMIA With regard to energy consumption, Temp. Water vapour content in g/m at humidity of air dehumidification has one °C 100% distinct advantage: Energy expenditure is limited 10.2 12.8 exclusively to the air volumes 10.4 13.8 17.3 present. The mechanical heat that is released by the dehumidification 13.8...
Page 13
Humidity measuring unit CMG 100 Water vapour condensation Condensation heat Because the capacity for the If the moisture that it is to be maximum possible volume of The energy transferred to the air condensed is not introduced by water vapour increases as the air is...