Problem
The air is not cool
or warm enough.
The air conditioner
makes strange
noises.
Unpleasant odours
permeate the
room.
Steam is produced
on the indoor unit.
The outdoor unit
fan continues to
operate when the
air conditioner is
turned off.
Water drops
from the piping
connections of the
outdoor unit.
Steam is produced
on the outdoor
unit.
• Close the windows and doors to maximize the cooling and heating
• If the Cool mode is stopped and then started immediately, cool air
comes out after about 3 minutes to protect the compressor of the
outdoor unit.
• When the Heat mode is started, warm air does not come out
immediately to prevent cool air from coming out at the beginning.
may be decreased. Avoid exceeding the maximum pipe length.
• In certain conditions (especially, when the outdoor temperature is
lower than 20°C), a hissing, rumbling, or splashing sound may be heard
while the refrigerant is circulating through the air conditioner. This is a
normal operation.
• When you press the
may be heard from the drain pump inside the air conditioner. This noise
is a normal sound.
• If the air conditioner is running in a smoky area or if there is a smell
entering from outside, ventilate the room properly.
• If both indoor temperature and indoor humidity are high, operate the
air conditioner in the Clean or Fan mode for 1 to 2 hours.
• If the air conditioner has not been operated for an extended period
of time, clean the indoor unit and then operate the air conditioner in
the Fan mode for 3 to 4 hours to dry the inside of the indoor unit for
removal of unpleasant odours.
• In winter, if the indoor humidity is high, steam may be produced around
the air outlet while the defrost function is running. This is a normal
operation.
• W hen the air conditioner is turned off, the outdoor unit fan may
continue to operate to reduce noise of the refrigerant gas. This is a
normal operation.
• Condensation may develop due to the difference in temperature. This is
a normal condition.
• In winter, when the air conditioner runs in the Heat mode, the frost
on the heat exchanger melts and steam may be produced. This is a
Solution