Hanwha HEBS II User Manual

Electronic blasting system

Advertisement

Quick Links

HEBS Ⅱ
User Guide
Electronic Blasting System

Advertisement

Table of Contents
loading

Summary of Contents for Hanwha HEBS II

  • Page 1 HEBS Ⅱ User Guide Electronic Blasting System...
  • Page 2: Table Of Contents

    Before Use Contents Warnings HEBS-II Components Each part name and role Before Use 3. Menu Structure 4. Maintenance Warnings Planner 4.1 Problem Solving at Planner Work 1.2 HEBS-II Components 3.1.1 Intro Each part name and role 3.1.2 Main Screen 4.2 Problem Solving at Blaster Work 1.3.1 Planner...
  • Page 3: Before Use

    This manual is described based on the settings before on-site provided. ① Blaster If a problem occurs by installing an app that is not provided by Hanwha, it can be difficult to respond immediately. ◦ ◦ If a user arbitrarily modifies the system settings or operating system software and experiences functional and ④...
  • Page 4: Each Part Name And Role

    Electronic Blasting System Electronic Blasting System Before Use Before Use 1.3.1 1.3.2 Each part Planner Logger name and role Blutooth Status LED Data Capture LED Power LED Charging Status LED Binding Post Touch Screen Planner Connector Battery PTT Button Hand Strap Holder Display NFC Antenna Scanning Button...
  • Page 5: Blaster

    Electronic Blasting System Before Use 1.3.3 Blaster How to Use Devices Scanning Type 2. 2 Logging Type Binding Post 2. 3 Tagging Type Wireless Firing Power LED Fire Button Power Button Touch Screen Tripod Connector How to Use Status Indicator LED Devices Fire Button Charging Port...
  • Page 6 Electronic Blasting System Electronic Blasting System How to Use Devices How to Use Devices 2.1.1 2.1.2 2.1.3 2.1.4 Scanning Charging Wiring Scanning Blasting Type ◦ Insert a detonator in the end of explosives. ◦ As shown in the figure, connect one end of harness wire to ◦...
  • Page 7 Electronic Blasting System Electronic Blasting System How to Use Devices How to Use Devices 2.2.1 2.2.2 2.2.3 2.2.4 Logging Charging Wiring Logging Blasting Type ◦ Equivalent to 1) Charging Explosives of 2.1 Scanning Type. ◦ Connect one end of harness wire to the positive terminal of ◦...
  • Page 8: Tagging Type

    Electronic Blasting System Electronic Blasting System How to Use Devices How to Use Devices 2.3.1 2.3.2 2.3.3 2.3.4 Tagging Charging Wiring Tagging Blasting Type ◦ Equivalent to 1) Charging Explosives of 2.1 Scanning Type. ◦ Equivalent to 2) Wiring of 2.2 Logging Type. ◦...
  • Page 9 Electronic Blasting System Electronic Blasting System How to Use Devices How to Use Devices 2.4.1 2.4.2 2.4.3 Wireless Blast network configuration Charging and Wiring Proceed with Wireless Blasting Firing ◦ Connect all blasters used for wireless blasting through ◦ Refer to 2.1 - 2.3 for charging explosives, wiring, scanning, ◦...
  • Page 10: Planner

    Electronic Blasting System Menu Configuration 3.1.1 3.1.2 Planner Starting Screen Main Screen 3. Menu Configuration 3.1 Planner 3.2 Logger 3.3 Blaster Available to check the main menu. Menu Configuration Touch to start a new blasting.
  • Page 11: Main Menu

    Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Main Menu 3.1.3 3.1.3 Main Menu Group Mode - (a) Plan ① Section Design Group Mode ◦ Available to use for a group blasting when blasting ◦ Touch the button at the tunnel and outdoor.
  • Page 12 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.3 Main Menu 3.1.3 Main Menu Group Mode - (a) Plan Group Mode - (a) Plan ② Group Design ◦ Click ADD GROUP button at the bottom to add a group. EDIT ◦...
  • Page 13 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.3 Main Menu 3.1.3 Main Menu Group Mode - (a) Plan Group Mode - (a) Plan TIME GAP SYMBOL TEXT EXPLANATION SYMBOL COLOR FONT COLOR TEMPLATE Available to change the group time Available to change the symbol Available to edit the group Available to change the symbol...
  • Page 14 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.3 Main Menu 3.1.3 Main Menu Group Mode - (a) Plan Group Mode - (a) Plan ③ Row Design BINDING ◦ Click button at the bottom to add a ◦ There are two types of row.
  • Page 15 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.3 Main Menu 3.1.3 Main Menu Group Mode - (b) Scan Group Mode - (b) Scan ① SCAN ⑤ DETONATOR DELETE Aim to hit the red point on QR code of a detonator. Click Scan QR code of the detonator to delete again.
  • Page 16 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.3 Main Menu 3.1.3 Main Menu Group Mode - (b) Scan Group Mode - (b) Scan ⑧ GROUP ADD ⑨ GROUP DELETE ◦ Drag the slide button on the ◦ Drag the slide button (Blue Circle from page 19) previous page toward the GROUP ADD on the left to toward the GROUP DELETE on the right to move...
  • Page 17 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.3 Main Menu 3.1.3 Main Menu Group Mode - (c) Browser Group Mode - (c) Browser ① LIST ⑤ SELECT Click Select the First button on the left bottom Browser is the window to edit data looking at the to display CHECK box for each deck.
  • Page 18 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.3 Main Menu 3.1.3 Main Menu Group Mode - (c) Browser Group Mode - (c) Browser ⑥ HOLE ADD ⑦ REVERSAL Click button of the list item at the location to Inactivated reversal icon when selecting the entire add to open the menu, and click button.
  • Page 19 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.3 Main Menu 3.1.3 Main Menu Basic Mode - (a) Scan Basic Mode - (a) Scan ① STARTING TIME Input the starting time for blasting before scanning. Without input, previously input value becomes the starting time.
  • Page 20 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.3 Main Menu 3.1.3 Main Menu Basic Mode - (b) List Basic Mode - (b) List ① DETONATOR ADD ④ DETONATOR INFORMATION EDIT To add new detonator, click button at the bottom screen to display To edit one detonator information, click and select the detonator to edit DETONATOR ADD screen.
  • Page 21 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.3 Main Menu 3.1.3 Main Menu Software Mode - (a) Before Starting Software Mode - (a) Before Starting ① SAVE DESIGN FILE IN PLANNER ② IMPORT DESIGN FILE To use the software mode, first use the blast design program to design and Press 'SAVE' file inside ‘STORAGE’.
  • Page 22 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.3 Main Menu 3.1.3 Main Menu Software Mode - (b) Scan Software Mode - (b) Scan To use the software mode, first import the design file prepared in the blast ‘...
  • Page 23 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.3 Main Menu 3.1.3 Main Menu Software Mode - (c) List Software Mode - (c) List ① EDIT FLAG SETTING Set flag to search specific Available to edit hole ID, tag number, detonator ID, delay time, and condition. ID onsite.
  • Page 24: Start Blasting

    Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.4 3.1.4 Start New Blasting Start New Blasting Basic Mode ’ Available to design the pattern for Start New Basic mode is equivalent to '3.1.3 Basic Mode Blasting fast by using a simple blast pattern at the bottom of main screen.
  • Page 25 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.4 Start New Blasting 3.1.4 Start New Blasting Openpit Mode Outdoor Mode Conveniently design the blast pattern used for outdoor blasting. ① OUTDOOR INFORMATION Group Number Set the number of groups. If its number is not always Relay Mode Determine the sequence of blasting by the first hole ◦...
  • Page 26 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.4 Start New Blasting 3.1.4 Start New Blasting Outdoor Mode Outdoor Mode ② TIME INFORMATION ③ BLAST DESIGN INFORMATION Group Time Gap ◦ Set the time gap between rows. ◦ After checking if set information is correct, set whether to add a Space Time Gap Set the time gap for space.
  • Page 27 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.4 Start New Blasting 3.1.4 Start New Blasting Tunnel Mode Tunnel Mode ② EXPANDED GROUP INFORMATION Conveniently design the blast pattern used in the tunnel blasting. ① DEEP BLAST GROUP INFORMATION Number of Groups Input the number of expanded groups.
  • Page 28 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.4 Start New Blasting 3.1.4 Start New Blasting Tunnel Mode Software Mode ③ EXTERNAL GROUP INFORMATION ④ FLOOR GROUP INFORMATION ⑤ BLAST DESIGN INFORMATION CREATION ① ‘3.1.3 (3) - (a) Save CSV file in the Planner as in the step ' Before Starting'.
  • Page 29: Communication 58

    Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.5 3.1.5 Communication 3.1.5 Communication Communication Logger Information Line Test Check short circuit or abnormal condition during wiring. Judgement Resistance Wiring Track Current Warning Ω ↓ Criteria Short Circuit (Leakage) Ω...
  • Page 30 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.5 Communication 3.1.5 Communication Communication Communication ① COMMUNICATION Check abnormal condition of every detonator once after the completion of wiring, scanning, logging and tagging. ② POLLING TEST Continuously check abnormal condition of every detonator until the user stops.
  • Page 31: Data Transmission

    Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Data transmission 3.1.5 Communication 3.1.6 3.1.6 4) ID Check Data 1) Data Transmission transmission If the detonator connector is damaged, connect the detonator leg wire to check detonator ID. ① ③...
  • Page 32: Others

    Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Data transmission Others 3.1.6 3.1.7 3.1.7 Device Search Others Storage - (a) Internal Storage ·SD Card Select Device Search tap at the top In case of broken Planner during working, mount SD card to on the Data Transmission screen.
  • Page 33 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Others Others 3.1.7 3.1.7 Storage - (b) Option Menu Storage - (b) Option Menu ① SELECT Available to select item. Cancel ◦ Cancel selection. ② SAVE Copy Available to copy selected item. ◦...
  • Page 34 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.1.7 Others 3.1.7 Others 3.1.7 Others 3.1.7 Others Settings - (a) Cancel Settings - (b) Cancel Settings - (c) Feedback Settings - (d) Others ① ALL DELETE ① SOUND FEEDBACK ①...
  • Page 35: Main Menu

    Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.2.1 3.2.2 3.2.3 3.2.3 Line Test Logger Main Menu DET ID Check Line Test Current MES Current Available to select each menu on the screen by using a Available to check the ID and delay time (if entered) of Check the current, leakage current and resistance of ◦...
  • Page 36: Line Test 71

    Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.2.3 Line Test 3.2.3 Line Test 3.2.4 Leakage Current Line Resistor Information MES Leakage Current MES Line Resistor MODEL Model Name ◦ ◦ ◦ μ Display present leakage current value by A unit.
  • Page 37: Blaster

    Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Setting 3.3.1 3.3.2 3.3.3 3.3.3 Blaster Start Screen Main Screen Setting Communication Channel Available to check the program version of corresponding Check the ID number and motion mode of corresponding blaster on the first screen appeared when pressing the blaster on the screen center.
  • Page 38 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.3.3 Setting 3.3.3 Setting 3.3.3 Setting 3.3.3 Setting Screen Saving Time Language Setting System Date Setting Password Change Set the system date of corresponding blaster. Set the configuration of blast, change the password used to start firing. Set the time to turn off the blaster screen.
  • Page 39: Configuration Setting

    Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.3.4 3.3.4 Blast Configuration Setting 3.3.4 Blast Configuration Setting Blast Configuration Blaster & Repeater Blaster & Repeater Setting Device Registration Standby ① ② ③ ④ ⑤ Connect Blaster & Repeater to the Available to check previous registration Transmit the signal requested for the Check the registration signal at the remote,...
  • Page 40 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.3.4 Blast Configuration Setting 3.3.4 Blast Configuration Setting 3.3.4 Blast Configuration Setting Remote Remote - (a) Device Registration Remote - (a) Device Registration Device Registraion ▶ ▶ ▶ ▶ ◦ Connect repeater and blasters Connect all blasters and repeater used for Press the search button to search blasters in...
  • Page 41 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.3.4 Blast Configuration Setting 3.3.4 Blast Configuration Setting Remote - (b) Blast Network Configuration Remote - (b) Blast Network Configuration Available to edit the connection configuration of Repeater and Blaster registered in the remote.
  • Page 42 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.3.4 Blast Configuration Setting 3.3.4 Blast Configuration Setting Remote - (c) Blast Group Setting Remote - (c) Blast Group Setting ▶ ▶ ▶ ▶ ‘ ▶ Touch the blast group configuration. If entering the first blast group setting after Currently selected item shall be displayed If a blaster is selected, a button,...
  • Page 43 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.3.4 Blast Configuration Setting 3.3.4 Blast Configuration Setting Remote - (c) Blast Group Setting Remote - (c) Blast Group Setting ① Change Blast Mode ▶ ▶ If a device existed in the move list is selected, The properties of blast group and blasters it is available to remove the device by tapping (individual blast) can be edited only when they...
  • Page 44 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.3.4 Blast Configuration Setting 3.3.4 Blast Configuration Setting Remote - (c) Blast Group Setting Remote - (c) Blast Group Setting ▶ Regular Interval ▶ Individual Interval ▶ Simultaneously In a regular interval mode, Modify Group If pressing the blast button once, blasters in If pressing the blast button once, all blasters Interval button shall be displayed.
  • Page 45 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration 3.3.4 Blast Configuration Setting 3.3.4 Blast Configuration Setting Remote - (c) Blast Group Setting Remote - (c) Blast Group Setting ② Inactivate ③ Move Group ④ Remove Group ▶ ▶ ▶...
  • Page 46: Start Blasting

    Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Start Blasting Start Blasting 3.3.5 3.3.5 3.3.5 Start Blasting Blaster Blaster ▶ ▶ To proceed with the blast, touch the Start Blasting on Download the electronic data for detonator from the screen.
  • Page 47 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Start Blasting Start Blasting 3.3.5 3.3.5 Blaster Blaster ▶ ‘ ’ ▶ ▶ ▶ Tap the List Button and confirm the Download up to 3,000 detonators If any of the downloaded data has duplicate Confirm all IDs and delay times downloaded.
  • Page 48 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Start Blasting Start Blasting 3.3.5 3.3.5 Blaster Starting Wireless Blast Blaster Starting Wireless Blast - (a) - (a) ▶ ▶ Touch ‘Start Wireless Blast’ button. It is not possible Blaster shall be maintained for a blast standby to maneuver the corresponding blaster after the mode.
  • Page 49 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Start Blasting Start Blasting 3.3.5 3.3.5 Blaster Starting Single Blast Blaster Starting Single Blast - (b) - (b) ▶ ▶ ‘ ’ Proceed with the communication with a Touch Start standalone blast on the screen.
  • Page 50 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Start Blasting Start Blasting 3.3.5 3.3.5 Blaster Starting Single Blast Blaster Starting Single Blast - (b) - (b) ▶ Charge energy in the electronic detonator ▶ Screen for standby after the complete recharging. ▶...
  • Page 51 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Start Blasting Start Blasting 3.3.5 3.3.5 Repeater Remote ▶ ▶ ▶ ▶ ▶ To proceed with the blast, touch the Start Blast After checking ID of the repeater, carry out the Check the repeater connected to the A blasting network shall be checked for the Check the connection.
  • Page 52 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Start Blasting Start Blasting 3.3.5 3.3.5 Remote Remote ▶ ▶ ▶ ▶ Available to check the condition after the In case of detecting a detonator with Step to check the proceeding of recharging Input password.
  • Page 53 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Start Blasting Start Blasting 3.3.5 3.3.5 Remote Remote ▶ Each hit ▶ ▶ ▶ Standby screen for blasting after the complete If pressing ARM and FIRE buttons If pressing ARM and FIRE buttons ▶...
  • Page 54 Electronic Blasting System Electronic Blasting System Menu Configuration Menu Configuration Start Blasting Start Blasting 3.3.5 3.3.5 Remote Remote ▶ All blasting mode except Each hit ▶ ▶ ▶ If the blasting group has different mode with After entering the ARM phase, touch the Each blaster that carries out the discharge All groups are Charging and communicating 'Each hit', the starting timing of each blasters...
  • Page 55: Maintenance

    Electronic Blasting System Maintenance Problem Contaminated Lens Solving at Symptom When scan speed slows down or it is difficult to scan. ◦ Planner ◦ Resolution Clean the lens with soft cloth and retry. 4. Maintenance Work 4.1 Problem Solving at Planner Work Damaged QR-CODE 4.2 Problem Solving at Blaster Work ◦...
  • Page 56 Electronic Blasting System Electronic Blasting System Maintenance Maintenance Keypad Operation Error Symptom Keypad is not operated. Logging fails ◦ ◦ Resolution ◦ Symptom Not able to receive logging data during logging. Resolution A) Press the power button for long 5 seconds for rebooting. ◦...
  • Page 57 Electronic Blasting System Electronic Blasting System Maintenance Maintenance Problem Disabled Screen Control Solving ① Safety Standby Global detonator occurs after wiring In a safety standby after blast/discharge, it is unable to control ◦ Symptom More than one shot have been detected in Global Detonator Search after the end of communication with at Blaster the screen.
  • Page 58 Electronic Blasting System Electronic Blasting System Maintenance Maintenance Disabled Wireless Communication Lost Password ① Change a device to wireless channel among paired devices, change ID or device Request A/S mode (Remote, Blaster, Repeater): Pairing should be done again due to the Unable to Recharge initialization of pairing information.
  • Page 59 Electronic Blasting System Electronic Blasting System Maintenance Maintenance Problem How to handle misfire Misfired Detonator: Damage on part of PCB Solving ① ① Check the location of misfired hole and check if detonation lead is visible. Symptom Damage on power unit or communication unit. ②...
  • Page 60 Electronic Blasting System Electronic Blasting System Maintenance Maintenance Misfired Detonator: Damage on the capacitor Misfired Detonator: Damage on ignition head ① ① Symptom Damage on the power capacitor. Symptom Damage on ignition head or fall off of welding part. Possible misfire, if the detonator is recovered to try firing again, the charging voltage A) In this case, firing will not occur after the trial of re-firing.
  • Page 61: Hebs-Ii Technical Data Sheet

    Electronic Blasting System Appendix Explanation Features HEBS-II Technical Data Sheet HiTRONIC is a high precision electronic detonator ◦ Normal firing even in short circuit of main bus after blast order. Appendix with an innovative safety, a high reliability on firing ◦...
  • Page 62 Electronic Blasting System Appendix Appendix п HiTRONIC Blaster * Contact Hanwha's technical representatives for custom made lengths. *Need to consult with the technician about maximum operating distance and detonator quantity. Type Folded Spool Dimension 242 x 189 x 52 mm...
  • Page 63 Electronic Blasting System Electronic Blasting System Appendix Appendix Planner Logger Dimension Dimension 155 x 75.5 x 18.6 mm 186 x 78.7 x 38.5 mm Maximum Detonator Capacity 1,000 per Planner Maximum Detonator Capacity 500 per Logger Weight Maximum Lead in Wire 249 g 2,000 m Operating Temperature...
  • Page 64 Alonso de Cordova 5870, Office 707, Las Condes, Wire - Cu 0.6mm, 0.075 Hanwha Corporation Explosives Santiago, Chile Hanwha Building 17th floor 86 Cheonggyecheon-ro, Properties Wire insulation - PE, Outer diameter - 1.2mm TEL. +56 2 2993 7542 Jung-gu, Seoul, Korea 04541 E-mail hmschile@hanwha.com...
  • Page 65 Hanwha Corporation Explosives Hanwha Building 17th floor 86 Cheonggyecheon-ro, Jung-gu, Seoul, Korea 04541 TEL. 02-729-1211 FAX. 02-729-1850 E-mail. commercial@hanwha.com...

Table of Contents