Hide thumbs Also See for SSZ-RZ3:

Advertisement

Quick Links

INSTALLATION AND SYSTEM DESCRIPTION
FOR SSZ CONTROL UNIT
TYPE SSZ-RZ3
MADE IN GERMANY
1
www.ssz-gmbh.de
info@ssz-gmbh.de
Thüringerstrasse 17, 46286 Dorsten

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSZ-RZ3 and is the answer not in the manual?

Questions and answers

Summary of Contents for SSZ SSZ-RZ3

  • Page 1 INSTALLATION AND SYSTEM DESCRIPTION FOR SSZ CONTROL UNIT TYPE SSZ-RZ3 MADE IN GERMANY www.ssz-gmbh.de info@ssz-gmbh.de Thüringerstrasse 17, 46286 Dorsten...
  • Page 2 This Operating Manual applies to control unit • Type: SSZ- RZ3, Performance Level PL d (in system) Category 3, acc. to EN ISO 13849-1 to be connected to: SSZ-Safety Mats Tel: +49 236940 94 and SSZ-Safety Rails and SSZ-Safety Bumpers.
  • Page 3: Table Of Contents

    The following documents from the purchaser also apply in addition to these instructions: • The drawing of the configuration (optional) • The cable diagrams (optional) www.ssz-gmbh.de info@ssz-gmbh.de Thüringerstrasse 17, 46286 Dorsten...
  • Page 4: About This Operating Manual

    The control units may also be used to generate warning signals SSZ-RZ3 control units can be supplied either with 24 V AC/DC or of persons. The control unit is designed for analysis and control with 230 V AC.
  • Page 5: Safety Recommendations

    An enclosure with an electronic module and plug-in connec- IN CASE OF ANY FAILURE, SWITCH OFF THE UNIT! tions SSZ-RZ3 control unit shall be switched off in case of any failure 1 x operating manual or defects. Immediately after delivery is received, it shall be checked for completeness and visual status.
  • Page 6: Control Unit Labelling

    The control units correspond to category 3, Performance Level PLd - in compliance with EN ISO 13849-1. NOTE: The control unit is a part of the system. SSZ a pressure-sen- sitive device + a control unit, PLd is the highest safety level for the entire system.
  • Page 7: Technical Parameters

    TECHNICAL PARAMETERS SSZ-RZ3 TESTING BASICS EN ISO 13849-1/2, EN ISO 13856 1-3 Nominal supply voltage SSZ-RZ3 24 AC/DC; 230 V Allowable voltage 10.6 VDC - 36 VDC or 8 VAC - 24 VAC; 230V Max . current consumption 290mA@12VDC; 135mA@24VDC; 250mA@24VAC...
  • Page 8 SSZ-CONTROL UNITS, IN *SSZ-RZ3 unit is a part of the system: COMBINATION WITH A PRESSURE- SSZ-pressure-sensitive device in connection SENSITIVE DEVICE (SAFETY MATES, with SSZ-safety unit, therefore, despite EDGES, BUMPERS) MAY OBTAIN THE PL e category, obtained by SSZ-RZ3 unit, HIGHEST SAFETY LEVEL OF PL d.
  • Page 9: Safety Unit

    RR terminals.. Relays output Relays output Relays output RESET button RESET button L (230V AC) N (230V AC) +24V AC/DC The SSZ-RZ3 control unit is factory set to operate with automatic reset. www.ssz-gmbh.de info@ssz-gmbh.de Thüringerstrasse 17, 46286 Dorsten...
  • Page 10: Connecting Of Safety Unit

    SSZ-RZ3 control unit automatic reset mode. If the Reset switch is in position `0`the SSZ-Control unit works in manual reset mode. In this case the Additional examples for each control units shall be available in Reset button connected on Terminals RR shall be pressed and the operating instructions of a given control unit.
  • Page 11 SSZ-RZ3/RZ3B CONTROL UNIT CONNECTION TO MACHINE OPERATING SYSTEM Safe stop by intern contacts in manual reset Safe machine stop by external devices in automatic reset Safe stop by external devices in manual reset Safe stop by intern contacts in automatic reset www.ssz-gmbh.de...
  • Page 12: Mounting

    MOUNTING Safety units of SSZ-RZ3 type are mounted on a DIN 35 mm rail, see the drawing below. MAINTENANCE AND CONTROL OF PROPER FUNCTIONALITY PROPER FUNCTIONALITY CONTROL FOR SSZ-RZ3 AND SSZ- Danger of electric shock! RZ3B UNIT: AUTOMATIC RESET CONTROL 1.
  • Page 13 1. Press the SSZ-pressure-sensitive device installations of other components / devices in the system shall be prohibited. The SSZ control 2. Make sure that no one of the SSZ pressure sensitive devices unit shall be the only device suitable for control is pressed of SSZ sensitive devices.
  • Page 14 PLd , the system in the standby mode is controlled by the unit. • Control unit SSZ-RZ3 has been designed in line with the EU’s engineering pattern and checked and approved with regards to electromagnetic compatibility, ventilation, cooling and vibrations.
  • Page 15: Storage And Transport

    When the service life of a B2B device fessional electronic solutions, designed exclusively for industrial expires, it can be returned to the SSZ GmbH for proper utilisation. applications (so called, B2B devices). Unlike the commonly used...
  • Page 16 Thüringerstrasse 17, 46286 Dorsten-Wulfen + 49 2369/4094 + 49 2369/21597 info@ssz-gmbh .de ssz-gmbh .de ALL RIGHTS RESERVED Version 2017 www.ssz-gmbh.de info@ssz-gmbh.de Thüringerstrasse 17, 46286 Dorsten...