Ankersmid Sampling AHL Series User Manual

Heated sample lines

Advertisement

Quick Links

Ankersmid Sampling
User Manual
Heated sample lines Series AHL
Ankersmid Sampling
Neerlandweg 21
2610 Wilrijk
Belgium
User Manual AHL, Edition 09/2016
www.ankersmidsampling.com
info@ankersmidsampling.com
Page 1 of 18
© Reproduction of this document or its content
is not allowed without permission of Ankersmid.
Technical Details Subject to Change

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AHL Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Ankersmid Sampling AHL Series

  • Page 1 Ankersmid Sampling User Manual Heated sample lines Series AHL Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com is not allowed without permission of Ankersmid. 2610 Wilrijk info@ankersmidsampling.com Belgium Page 1 of 18...
  • Page 2: Table Of Contents

    I.2. Shortening a heated line with self-limited heating tape…………………………………… J. During operation …………………………………………………………………………………………… K. Installation guidelines …………………………………………………………………………………… L. Service ………………………………………………………………………………………………………… M. Receipt and storage of goods………………………………………………………………………… Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com is not allowed without permission of Ankersmid.
  • Page 3: Used Terms And Signal Indications

    EC recommendation 73/23 EEC and the recommendation of electromagnetic compatibility 89/336 EEC. Declaration of conformity EU Declaration of conformity is available at Ankersmid Sampling. Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com...
  • Page 4: Safety Instructions

    EC conformity is indicated by the CE marking. IMPORTANT: This equipment is, in its standard version, not explosion-proofed! Ex-proofed equipment is specially marked. Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com...
  • Page 5: Warranty

    Warranty If the equipment fails, please contact your ANKERSMID SAMPLING dealer. The warranty is covered for a period of 1 year countable from the first day of delivery (as also specified in our normal terms and conditions of sale) when the apparatus (*) is handled and assembled correctly, installed according good craftsmanship, treatment and use or operation of the equipment.
  • Page 6: Description

    Heated sample line Gas cooler Peristaltic pump for condensate removal Figure 2 Standard flow chart of a heated gas sample line Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com is not allowed without permission of Ankersmid.
  • Page 7: Area Of Application

    There will be no such problems if you employ the available Winkler hose controller systems. Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com...
  • Page 8 5-pin plug (>10A, max. 20A) Colour code: Temperature sensor (standard Pt100) = yellow Power supply (standard 230VAC) = brown (L) / blue (N) Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com is not allowed without permission of Ankersmid.
  • Page 9: Shortening A Heated Line With Self-Limited Heating Tape

    Unscrew the hard end caps Remove the fixed adhesive tape of the corrugated cover and cut the cover carefully to the required length Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com...
  • Page 10 Remove the fixed adhesive tape from the copper braid and cut carefully to the required length CAUTION Open and remove the subjacent hose clamp Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com...
  • Page 11 Remove the fixed adhesive tape and cut the heating cable to the required length Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com is not allowed without permission of Ankersmid. 2610 Wilrijk info@ankersmidsampling.com...
  • Page 12 The silicone will set up within 30 minutes with a complete cure after 24 hours. CAUTION Do not carry out any dielectric test or measurement of insulation resistance until the silicone is completely cured. Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com...
  • Page 13 Ensure that all fixings are connected with the stainless steel pipe to avoid a shift of the materials. Screw on the hard end caps. Perform a final electrical inspection. Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com...
  • Page 14: During Operation

    9. Avoid exposing the hose to direct solar radiation for any length of time or, if unavoidable, provide suitable protection. Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com...
  • Page 15: Installation Guidelines

    Remedy: Bends at connection points. Wrong Right Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com is not allowed without permission of Ankersmid.
  • Page 16 Remedy: Always leave sufficient space between the hoses. Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com is not allowed without permission of Ankersmid.
  • Page 17: Service

    The permissible bending radius depends on the material and the nominal diameter (DN) of the heated hose. As a general rule: Minimum bending radius > 5 x outer hose diameter Ankersmid Sampling User Manual AHL, Edition 09/2016 © Reproduction of this document or its content Neerlandweg 21 www.ankersmidsampling.com...
  • Page 18: Receipt And Storage Of Goods

    The goods and the delivery note should be compared. If any difference is noted please contact your Ankersmid Sampling contact person. The delivery should be checked for any transport damage. If any anomaly is noted, please contact the transport insurer immediately notifying of the damage.