Section 2 - Installation Instructions; Shipment And Transit; National Sanitation Foundation Compliance Requirements; Installation - Stoelting U3-02A Owner's Service Manual

Mix pump
Table of Contents

Advertisement

2.1 SHIPMENT AND TRANSIT

The mix pump has been completely assembled, operated
and inspected at the factory. Upon arrival at the final
destination, the mix pump must be checked for any
damage that may have occurred during transit.
The mix pump should arrive in satisfactory condition. THE
CARRIER IS RESPONSIBLE FOR ALL DAMAGE IN
TRANSIT, WHETHER VISIBLE OR CONCEALED. Do not
pay the freight bill until you have checked the equipment.
Have the carrier note any visible damage on the freight bill.
If concealed damage and/or shortage is found later, advise
the carrier inspector within 10 days and request inspec-
tion. The customer must place claim for damages and/or
shortages in shipment with the carrier. Stoelting, LLC
cannot make any claims against the carrier.
2.2 NATIONAL SANITATION FOUNDATION
COMPLIANCE REQUIREMENTS
In order to comply with "NSF International" (NSF) code
#6:
A. This unit (remote pump) must be installed with a
"NSF" listed refrigerated mix transfer line. The mix
transfer line must be pitched to cooler, with no sags
or low points, to allow complete drainage (Fig. 2).
B. The product at the mix pump and in transfer lines
must be maintained below 41°F (5°C.)
COOLER WALL
10 FT. LIFT
MAXIMUM
PUMP
CHECK
VALVE
MIX
CONTAINER
SECTION 2
INSTALLATION INSTRUCTIONS
20 FT. MAXIMUM
REFRIGERATION
UNIT FOR MIX LINE
Figure 2

Mix Transfer Line

3

2.3 INSTALLATION

A. Follow the steps below to install the mix pump in an
upright position on the wall using optional pump
mounting kit. Allow clearance for a mix container
under pump. See Figure 2.
1.Mount by locating four (4) hole centers on cooler
wall using mounting bracket as template.
WARNING
Risk of Personal Injury/property Damage
Verify electrical and refrigeration line location inside
and behind the cooler's walls defore drilling.
2. Drill four (4) 1/2 inch diameter holes into cooler
wall 3/4 inch deep. See Figure 3.
3.Insert well-nut to flange and apply silicone sealant
around outside diameter of flange and cooler wall.
4.Repeat steps 2 & 3 for other located hole centers.
5.Mount bracket to cooler wall with supplied wing
screws. Hand tighten until secure.
6.Thread plastic standoffs (small parts bag) onto all
three pump mounting studs located under the
pump until bottomed.
7.Mount pump to bracket with wing nuts. Pump will
be held above the bracket by the standoffs.
FREEZER