LEGRAND XL3 S 160 Series Specifications

LEGRAND XL3 S 160 Series Specifications

Distribution cabinets

Advertisement

XL³ S 160
DISTRIBUTION CABINETS
THE GLOBAL SPECIALIST IN ELECTRICAL
AND DIGITAL BUILDING INFRASTRUCTURE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XL3 S 160 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for LEGRAND XL3 S 160 Series

  • Page 1 XL³ S 160 DISTRIBUTION CABINETS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE...
  • Page 2 Legrand reserves the right to change the specifications and illustrations without notice. All illustrations, descriptions and technical information included in this document are provided as indications and cannot be held...
  • Page 3: Table Of Contents

    Wiring and connection ........14-15 Accessories mounting ........16-17 Flush-mounting cabinets Preparing flush-mounting cabinets ....18 to 27 Mounting devices ..........28-29 Wiring and connection ........30-31 Accessories mounting ........32-33 Accessories and spare-parts ....34-35 S 160 WORKSHOP SPECIFICATIONS CONTENTS WWW.LEGRAND.COM...
  • Page 4: Safety Instructions

    Voltage / Current / Temperature values other than those specified in the Documentation. Legrand declines all responsibility for any modification or repair of the equipment making up the enclosure that is not authorized by ■...
  • Page 5 However, it is always the customer’s responsibility to verify and validate that Legrand products are suitable for its installation and use. The customer must ensure proper installation, maintenance and operation of the equipment to avoid any risk of injury to personnel or damage to property in the event of product failure, especially for applications that require a very high level of safety (e.g., those...
  • Page 6: Surface Mounting Cabinets

    24 modules and from 4 to 8 rows of 36 modules. Possibility to choose a special col- our from a panel of 197 shades: RAL only possible on metal parts. For any request on technical pos- sibilities extra costs, please contact technical support: support-technique-edia.fr-lgs@legrand.fr...
  • Page 7 3 372 18 Number of rows Number of modules 3 372 64 3 372 65 3 372 66 3 372 67 3 372 68 Metal door (flat) 3 372 84 3 372 85 3 372 86 3 372 87 3 372 88 Glass door (flat) S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 8 SURFACE MOUNTING CABINETS Preparing the cabinets for use The XL³ S 160 cabinets are supplied in 2- Fix the cabinet by using 4 screws Useful Useful Cat. Nos a cardboard packaging, reusable for (mm) (mm) (Ø 6mm minimum) and 4 washers. 3 372 02 delivery to the site.
  • Page 9 3 372 06 1068 3 372 07 1218 1133 3 372 08 1368 1283 3 372 14 3 372 15 3 372 16 1068 mod. 3 372 17 1218 1133 3 372 18 1368 1283 S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 10 SURFACE MOUNTING CABINETS COMBINATION/JOINING KIT (CAT. NO 3 374 07) The cabinets can be combined vertically ■ Fitting by using the kit Cat.  No 3 374 04 Join the cabinets together by using the 4 screws + nuts provided in the kit composed of 4 screws and 4 nuts.
  • Page 11 3 372 15 5 rows 2 faceplates of 3 372 16 modules 3 rows 1 faceplate of 4 rows + 3 372 17 1 faceplate of 3 rows 2 faceplates of 3 372 18 4 rows S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 12 SURFACE MOUNTING CABINETS Connect the conductor (Cat. No 3 397 53) FACEPLATES MOUTING FITTING THE DOORS to the faceplate with a screw, a nut and 2 (CONTINUED) The solid or glass doors can be fitted to washers (not supplied) in order to ensure open to the left or the right (see selection the continuity.
  • Page 13 3 372 78, 3 372 87, 3 372 88 are equipped with 2 handles. The axis should be properly clipped in The door axis are designed to be the specified location (see photo above). and removed without tools. So the door installation is made easier. S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 14: Mounting Devices

    SURFACE MOUNTING CABINETS Mounting devices Cabinets are delivered with the rails of To replace the chassis, it must be Twist both lugs 90° inwards: the chassis in the upper position, i.e. inserted on the 2 lower studs and then Before ready to install the modular products on the 2 upper studs.
  • Page 15 DRX (with its adapter) on the extension Cat.no After 3 382 42. The rail must be in the low position (see paragraph 2). The mounting of the DPX³ 160 is detailed in section 2. S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 16: Wiring And Connection

    SURFACE MOUNTING CABINETS Wiring and connection The brass terminal block Cat. No 0 373 00 INSERTING OF THE CABLES/ can be fixed on the lugs supplied with the CABLES ENTRY cabinet (with the 2 screws and 2 nuts The XL³ S 160 are fitted with knockout supplied with the Cat. No 0 373 00).
  • Page 17 36 modules → maximum length 726 mm Fixing centres: 400  mm in 24  modules cabinets and 616  mm in 36  modules cabinets. Drilling: Ø 5 mm. Fixing screw: M5 + nuts (not supplied). 400 mm 510 mm Example with 24 modules cabinet S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 18: Accessories Mounting

    SURFACE MOUNTING CABINETS Accessories mounting BLANKING PLATES 5 MODULES (CAT. NO 0 016 60) 24 MODULES (CAT. NO 3 397 54) 36 MODULES (CAT. NO 3 397 55) The blanking plates allow covering the modular frames of the XL³ S 160 faceplates. You can use the 5 modules blanking plates Cat. No 0 016 60 (white colour RAL9003) and divisible in a module or half-module. It’s also possible to use the 24 modules Cat. No 3 397 54, and 36 modules Cat. No 3 397 55 blanking plate.
  • Page 19 ■ Example of a document holder mounting Remove plastic film double-sided adhesive type positioned at the back of the holder. Then, stick it wherever you want. Cat. Nos 0 365 80/81 : Cat. No 0 365 82 : Cat. No 0 097 99 : S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 20: Flush-Mounting Cabinets

    24 modules and from 4 to 8 rows of 36 modules. Possibility to choose a special colour from a panel of 197 shades: RAL only possible on metal parts. For any request on technical pos- sibilities extra costs, please contact technical support: support-technique-edia.fr-lgs@legrand.fr...
  • Page 21 3 372 38 Number of rows Number of modules 3 372 64 3 372 65 3 372 66 3 372 67 3 372 68 Metal door (flat) 3 372 84 3 372 85 3 372 86 3 372 87 3 372 88 Glass door (flat) S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 22 FLUSH-MOUNTING CABINETS Preparing the cabinets for use The XL³ S 160 cabinets are supplied The 2 pack contains: 4  masonry DIMENSIONS in a cardboard packaging reusable for anchors, 8 fixing screws and 8 nuts: delivery to the site. 116 21,5 H1 H2 The 3 pack contains: 4 ...
  • Page 23 The set partition + isolation must have a minimum depth of 135  mm, including a minimum depth of 100 mm for the partition. (The anchors sealing is made at mid-depth of the cabinet, i.e. approximately 70 mm). S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 24 FLUSH-MOUNTING CABINETS FLUSH-MOUTING (CONTINUED) Seal the lugs then, furnish around the ■ Cut of the cable entries ■ Installation in the wall cabinet with some plaster, adhesive Knockout and cut the upper or bottom Position the cabinet at level against the mortar or concrete: side panel of the cabinets in order to run wall and draw the outlines.
  • Page 25 (or many) keyhole → side of the hinges 1- Fit the clip-nuts supplied on the sides of the cabinets in Minimum depth → no order to fix and adjust the frame: Maximum depth → yes S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 26 FLUSH-MOUNTING CABINETS FACEPLATES MOUNTING ■ Fitting ■ Configuration by cabinet size The XL³ S 160 are supplied with 1 or 2 Number of fixing Cat. Nos Number of faceplates faceplates (see the components in the points adjacent table). The faceplates are fixed 1 faceplate of 3 372 22 on the cabinet with captive screws:...
  • Page 27 (Cat. No 3 397 56). To achieve this, you must bend the connecting lug of the faceplate with The connection on the cabinet is made by pliers. screwing a M6 nut (not supplied) on the specified attachment points. S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 28 FLUSH-MOUNTING CABINETS FITTING THE DOORS The solid or glass doors can be fitted to 3- Rotate the axis on 90° to lock the open to the left or the right (see selection system. table page 5). The slots for the hinges and the door release are provided on both sides of the cabinet.
  • Page 29 The doors are equipped with studs for connecting the equipotential link conductor Cat. No 3 397 53. 1- Remove the dedicated plastic cover on the cabinet (2 covers available). Then, cut it to enable the cable to pass: S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 30: Mounting Devices

    FLUSH-MOUNTING CABINETS Mounting devices Cabinets are delivered with the rails of To replace the chassis, it must be Twist both lugs 90° inwards: the chassis in the upper position, i.e. inserted on the 2 lower studs and then Before ready to install the modular products on the 2 upper studs.
  • Page 31 DRX (with its adapter) on the extension Cat.no After 3 382 42. The rail must be in the low position (see paragraph 2). The mounting of the DPX³ 160 is detailed in section 2. S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 32: Wiring And Connection

    FLUSH-MOUNTING CABINETS Wiring and connection ■ Number of rectangular entries INSERTING OF THE CABLES/ PROTECTIVE CONDUCTORS AND IP CABLES ENTRY 2X DISTRIBUTION TERMINAL BLOCKS Number Rectangular knockout The XL³ S 160 are fitted with knockout entries First, you need to fit the mounting lugs modules Number and dimension cable entries in order to mount cable...
  • Page 33 Fixing centres: 400  mm in 24  modules cabinets and 616 mm in 36 modules cabinets. Drilling: Ø 5 mm. Fixing screw: M5 + nuts (not supplied). 510 mm 400 mm Exemple with 24 modules cabinet S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 34: Accessories Mounting

    FLUSH-MOUNTING CABINETS Accessories mounting BLANKING PLATES 5 MODULES (CAT. NO 0 016 60) 24 MODULES (CAT. NO 3 397 54) 36 MODULES (CAT. NO 3 397 55) The blanking plates allow covering the modular frames of the XL³ S 160 faceplates. You can use the 5 modules blanking plates Cat. No 0 016 60 (white colour RAL9003) and divisible in a module or half-module. It’s also possible to use the 24 modules Cat. No 3 397 54, and 36 modules Cat. No 3 397 55 blanking plate.
  • Page 35 ■ Example of a document holder mounting Remove plastic film double-sided adhesive type positioned at the back of the holder. Then, stick it wherever you want. Cat. Nos 0 365 80/81 : Cat. No 0 365 82 : Cat. No 0 097 99 : S 160 DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 36 ACCESSORIES AND SPARE PARTS CAT. NOS DESIGNATION CONTENTS Wall mounting lugs 4 lugs, 3 374 00 (supplied by 4) 8 screws, 8 nuts 12x2 flat bar 0 048 19 1 m length 1 bar 0 373 00 Additional brass bar 2 screws, 2 nuts 3 374 04 Kit for joining 4 screws, 4 nuts Open adhesive document holder -...
  • Page 37 1 holder 3 397 56 36 modules Clip-on adhesive holder 1 labels sheet 1 hinge 9 809 01 Door hinge 1 axis 2 supports 9 809 03 2 terminal block supports kit 2 nuts S 160 WORKSHOP SPECIFICATIONS ACCESSORIES AND SPARE PARTS WWW.LEGRAND.COM...
  • Page 38 Notes...
  • Page 39 To know more, check export.legrand.com All technical dat of the products inside this workshop specifications book are available www.export.legrand.com/en Click on >DOCUMENTATION & SOFTWARE >DOCUMENTATION S 160 S 160 DISTRIBUTION CABINETS DISTRIBUTION CABINETS WWW.LEGRAND.COM...
  • Page 40 FOLLOW US ALSO ON legrand.com youtube.com/user/legrand facebook.com/Legrand twitter.com/Legrand pinterest.com/legrandgroup instagram.com/legrandnews Head office and International Department 87045 Limoges Cedex - France Tel: + 33 (0) 5 55 06 87 87 Fax: + 33 (0) 5 55 06 74 55...

Table of Contents