Congratulations on your new wood stove, we are confident that you will be more than satis- fied with your new Heta stove. Especially if you follow the following advice and instructions. The Green 250 pellet stove is approved under EN 14785.
The burn pot must be empty Of wood pellets before start-up. Wood pellets Only burn wood pellets in the pellet stove, Heta recommends 6 mm wood pellets. Remember to close the pellet lid, otherwise the lid sensor will be activated and the wood pellets...
Transparent protective film Never open the stove door while the stove is in operation. When It is recommended that you remove the protec- the oven is switched on, all sur- tive film before using the Display to guarantee faces and glasses are extremely the best performance of the sensitive (touch) hot and should only be handled surface.
Menu overview Slide to turn on/off. Swipe for at tænde Justering Power Thermostat Combustion Manuel pellet setting feed Power Power level Power level Auto Calibrazione Ventilatore...
Page 8
Thermostat Temperature To select room temperature Temperature Combustion setting Combustion levels Combustion levels...
Page 9
Manual pellet feed Manual pellet feed Important The burn pot must be empty for wood pellets before start-up. See page 5. Manual pellet feed Manual pellet feed 00:00...
Page 10
Settings Settings System Menu Screen Menu Only for service technician Settings Time and Date Language Adjusting pellet quantity Display Menu Brightness Standby brightness Display stand-by Screen Saver Control panel address Restart Display Alarm with sound Delete errors System Info Background Display Info Text black/white...
Information Røggas temperatur Stue temperatur Luftstøm Ventila Flue gas temp. Room temp. Airflow Chimney fan 27°C 24°C 0 rpm Auger Combustion leve Next service Hours of Snegl Arbejdstid Tændinger opperation 2200 h 0.0 s Timer setting Er52 Possible menus: TIMER- DAILY 22°...
Settings 1. Select the desired language. Confirm or cancel the change 2. Set the correct date and time. Switch on/off manually on the display Change of output/heat On the display, you can switch between three Press and slide to the right on the display. different heat levels.
Emptying/Cleaning of the pellet tank (*) Inserting the burn pot after cleaning. Pellettank should be emptied and vacuumed for Fig. 2 dust and pellet remains at least monthly. Semi annually / Annually Internal flue pipe and chimney fan (*) The stove’s internal flue pipe must be kept free from ash and soot.
Vermiculitestone Smoke baffles A/B must be removed monhly to remove ash. See page 14. To remove all the stones, first remove A, then C, D, E, F and finally B. Fig. 4. The stones are put back in reverse order. NOTE: That the vermiculite stones are a porous material and must be...
Cleaning interval Parts / Frequency Daily Weekly Monthly Semi-/annually Burn pot Combustion chamber Glass Baffle plate Vermiculitestone Seals and gaskets Pellet tank Flue gas channel and chimney fan (*) Pressure switch (*) Convection fan (*) Internal flue pipe (*) Points marked with an asterisk (*) should only be carried out by an authorised dealer. If the directions and cleaning schedule in this cleaning manual are not observed the warranty will become void.
Green 250 ø80 1,88 0,10 Average temperature in the flue pipe connector: ~ 109°C. Pos. A, B and C fig. 1. * Weight tablel Scan-Line Green 250 Steel 160 kg Complete soapstone 242 kg Top soapstone 167 kg Top blackwood...
Adjustment of the combustion air stion produces dark flames, several factors may Before starting, see page 5 the section on be having an influence. Pellet type and chimney ignition and manual pellet feeding. Start the will be the most significant factors, and the fol- pellet stove in power 2, choose between basic lowing section describes the relevant solutions.
Error codes and descriptions Error Description of error Possible cause Solution codes code Er01 STB is tripped or defec- Mechanical circuit breaker if STB can be activated again by pres- tive (voltage fault) the pellet tank has been too sing the safety switch behind the hot with no visible faults in oven.
If the water content is very high, it will negatively impact the energy level, just as you risk more Heta A/S recommends using Premium wood ash build-up inside the chimney. However, wa- pellets from Heatlets.dk to get the most out ter is a necessary component of the wood pel- of your pellet stove.
Parts Vermaculite and burn pot Pos. Name Qty. 0023-024277 Vermiculite, side, left 0023-024279 Vermiculite, rear, top 0023-024280 Vermiculite, rear, bottom 0023-024281 Baffle, bottom 0023-024278 Baffle, top 0023-024415 Vermiculite, side, right 0023-023704 Burn pot Parts Gasket - Pellet lid 0023-024389 Gasket Parts - Door Pos.
Using pellets of poor quality or pellets made of - The warranty conditions specified below: materials other than pure wood can damage Heta wood-burning stoves are subjected to stove components. As a result, the warranty is thorough quality inspections throughout the considered null and void and the manufacturer’s...
Installation ..................25 Distance Provisions ................26 Disassembling soapstone before installation ........27 Stovedrawings/measurments ............28 Installation of HETA-climate Wi-Fi ............ 28 Installation of external fresh air ............29 EU Declaration of Conformity ............31 Remember The stove and chimney installation, must comply with local regulations, including those referring to national and European standards.
European and possibly local re- tions enclosed herein. gulations. You must follow local regulations with Heta A/S disclaims all liability in relation to in- regard to installation of chimney and connection correct use of the stove, abnormal usage by the to the chimney.
The chimney connection flow from the room where it is installed, but you have the possibility to add external combustion The flue gas system is dependent on a slight air flow. A sealed air intake can be connected to underpressure in th e combustion chamber and the stove’s air intake connector.
Distance Provisions There is a difference between installation next to We recommend a minimum of 5 cm to facilitate flammable wall or non-flammable wall. If the wall air circulation around the stove. is made of non-flammable material, the stove in If in doubt, contact your chimney sweep for ad- principle may be placed flush against it.
Installation of external fresh air kit Accessory External fresh air ø 80 mm 6000-026126 ø100 mm 6000-024610...
Page 30
Connection of external fresh air (fles pipe / fixed pipe) When using external fresh air, the piping must be removed the room (Flex pipe / fixed pipe) must be permanently mounted on the fresh air connection, the joint must be tight. Flex pipes / fixed pipes must be mounted on the outside the fresh air connection.
Adress Jupitervej 22, DK 7620 Lemvig EU Declaration of Conformity E-mail heta@heta.dk Website www.heta.dk DoC Scan-Line Green 250 2559-2021 Telephone +45 9663 0600 Product fiche Model identifier Scan-Line Green 250 The object of the declaration described above is Notified body relevant to the assessment and verification of...