Summary of Contents for RCT Power 63/25

  • Page 1 MANUAL Power Switch suitable for RCT Power Storage DC...
  • Page 2 Power GmbH. Any reproduction, distribution, translation or transmission in any form, electronic or mechanical, including photocopying, recording or storage on data carriers without the permission of RCT Power GmbH is a violation of the applicable copyright laws and will be prosecuted.
  • Page 3: Table Of Contents

    Mode of operation of the backup power switchover ................38 SCOPE OF DELIVERY ....................39 CIRCUIT DIAGRAM ....................40 RCT Power Switch 63/25, Art.-No. 310-0003 ..................40 RCT Power Switch 63/25-3, Art.-No. 310-0004 ..................41 INSTALLATION ......................42 Requirements for the installation site ....................42 Minimum distances ..........................42...
  • Page 4 STORAGE ........................ 49 DISPOSAL ....................... 49 DISCLAIMER ......................50 TECHNICAL DATA ....................51...
  • Page 5: About This Document

    The latest version can be found at www.rct-power.com. RCT Power GmbH reserves the right to make changes to specifications or documents without prior notice. RCT Power GmbH is not liable for any damages resulting from the use of this document.
  • Page 6: Target Group

    1.2 Target group These instructions are for qualified electricians. Only qualified electricians may carry out the activities described in this manual. 1.3 Symbols used This symbol indicates an imminently hazardous situation which, if the safety DANGER regulations are not followed, will result in death, serious injury or severe damage to property.
  • Page 7: Safety

    2 Safety 2.1 Personnel and qualifications To prevent damage to property and personal injury, the Power Switch must only be installed, commissioned and maintained by qualified personnel. Qualified personnel authorised to perform the tasks described in this document have the following knowledge: ƒ...
  • Page 8: Type Plate - Symbols And Characteristic Values

    • All electrical installations must be carried out in accordance with local and national standards and guidelines. • To avoid personal injury, ensure that electrically conductive surfaces of the entire PV system are earthed. • A malfunction may affect the safety of the Power Switch. Do not operate the Power Switch if it shows visible damage.
  • Page 9: Use And Function Of The Power Switch

    3 Use and function of the Power Switch 3.1 Intended use 3.1.1 System approvals The Power Switch may only be installed in the configuration with an RCT Power Storage DC. The components used and the electrical wiring are approved by the manufacturer RCT Power. 3.1.2 Permitted grid systems Depending on the version, the RCT Power Switch is permitted for the following grid structures: RCT Power Switch 63/25, Art.-No.
  • Page 10: Function

    3.2 Function 3.2.1 Tasks of the Power Switch Measurement and transmission of parameters required for energy management via integrated RCT Power ƒ Sensor Disconnection from the grid in the event of a grid failure/grid disturbance ƒ Reconnection on grid return/grid fault clearance ƒ...
  • Page 11: Selection Aid For Determining The Appropriate Version

    3.2.2 Selection aid for determining the appropriate version As explained in the section „Country approvals“, very different requirements apply to the design of the RCT Power Switch depending on the country and region. Please be sure to check the requirements of the respective grid operator before installation! All types listed below are designed for a maximum feed-in power of 30 kW.
  • Page 12: Mode Of Operation Of The Backup Power Switchover

    Failure or disruption of the public grid ƒ The Power Storage detects a grid failure and disconnects the internal mains relays. Only with Power Switch 63/25-3, short-term grid interruptions do not cause a grid disconnection! ƒ Relay K5* is activated by the Power Switch Board.
  • Page 13: Scope Of Delivery

    4 Scope of delivery Battery Position Quantity Designation Power Switch Cable gland M40 Cable gland M32 Cable gland M25 Cabel gland M20 Extension -M32 to M40- Extension - M25 to M32- Reduction -M50 to M40- Reduction -M50 to M32- Reduction -M20 to M12- (for pressure equalising valve) Locknut M50 Locknut M32 Locknut M25...
  • Page 14: Circuit Diagram

    5 Circuit diagram 5.1 RCT Power Switch 63/25, Art.-No. 310-0003 NOT buffered house load / additional generators* * max. total power of generators connected to X2 and X3: 30kW (25°C) Buffered consumers, Power Storage DC* NO producers! (responsible for backup power)
  • Page 15: Rct Power Switch 63/25-3, Art.-No. 310-0004

    5.2 RCT Power Switch 63/25-3, Art.-No. 310-0004 NOT buffered house load / additional generators* * max. total power of generators connected to X2 and X3: 30kW (25°C) Buffered consumers, Power Storage DC* NO producers! (responsible for backup power)
  • Page 16: Installation

    6 Installation 6.1 Requirements for the installation site DANGER Danger to life due to fire and explosion ƒ Do not mount the Power Switch on a combustible surface! ƒ Do not mount the Power Switch in areas where highly flammable substances are present! ƒ...
  • Page 17: Dimensions And Fastening

    6.3 Dimensions and fastening Power Switch 63/25 Power Switch 63/25-3 Enclosure openings for fastening: 4 x oblong hole Ø 5.5 Select a suitable type of fastening depending on the substrate, e.g. using 4 x expansion dowel S8 and 4 x chipboard/wood screw Ø5.5...
  • Page 18: Cable Entry And Cable / Conductor Types

    6.4 Cable entry and cable / conductor types Use the pre-embossings on the bottom! 16 - 28 mm 13 - 21 mm 9 - 17 mm 6 - 13 mm Pressure equalising valve Recommended cable type / Terminal strip Connection Remark cross-section NYY-J max.
  • Page 19: Connection Of The Power Switch

    6.5 Connection of the Power Switch The Power Switch is connected by means of spring-loaded terminals (Wago Cage Clamp ®). Only the Power Sensor and the Power Switch Board are connected to the RJ45 connector via the enclosed data cables. Max. cross-section Stripping length Terminal strip Wire type...
  • Page 20: Throughput Power

    7 Throughput power The thermal throughput power (rated power) and the maximum permissible ambient temperature are decisive for the maximum heating of the components within the Power Switch. In order not to cause unwanted tripping of miniature circuit breakers and residual current circuit breakers, these two parameters must remain within the permissible limits.
  • Page 21: Commissioning The Power Switch

    8.3.1 Configuration island mode The RCT Power Switch enables an off-grid operation to be set up in 1-phase as well as 3-phase mode. In 1-phase off-grid mode, the individual phases L1,L2 and L3 are bridged in off-grid operation. This makes it possible to use large single-phase loads in off-grid operation.
  • Page 22: Activation Of The Power Switch Via The App

    8.3.2 Activation of the Power Switch via the APP Step Description Start the „RCT Power APP“. Continue with DEVICE  SETTINGS  DEVICE SETTINGS (scroll down). Check the “Power Switch is available” box (scroll down). Press “FLASH” to save the settings permanently!  Power Sensor tuning...
  • Page 23: Disconnecting The Power Switch From The Power Supply

    9 Disconnecting the Power Switch from the power supply WARNING 1) Disconnect input terminal strip X3 from the power supply (Power Storage feed) Decommission the Power Storage (see the corresponding setup/manual), determine that no voltage is present and secure it against being switched on again! 2) Disconnect the input terminal strip X1 from the power supply (public grid) Disconnect the fuse elements between the public grid and the Power Switch, determine the absence of voltage and secure against reconnection!
  • Page 24: Disclaimer

    Although every effort has been made to ensure the accuracy and completeness of the information contained in this manual, no liability can be accepted for errors or omissions. RCT Power GmbH reserves the right to change the hardware and software features described herein at any time without notice.
  • Page 25: Technical Data

    Losses in standby mode, approx. Terminals Meter/Load/Backup load spring -loaded, up to16mm² Terminals RCT Power Storage spring-loaded, up to 6mm² Additional operation losses at P RATED 5/10/20/30kW and full feed from RCT Power 5/8/20/38 7/12/30/55 Storage, approx. Operating temperature range [°C] -5...+40 Relative humidity 5...95...
  • Page 26 SPEICHERTECHNOLOGIE NEU DURCHDACHT. STORAGE TECHNOLOGY RETHOUGHT. RCT Power GmbH Line-Eid-Str. 1 78467 Konstanz Tel: +49 7531 99677 0 E-mail: info@rct-power.com WWW.RCT-POWER.COM Technology and Design Made in Germany...