If the wire ends at the roof walkway, install a glider
end stop (6) on the last bracket (2)
6
WIRE ENDING ON THE ROOF WALKWAY
If the loose end of the wire a�er the last bracket has not been equipped with any factory-mounted terminal, it shall be
protected with wire end protector (7) by pressing or using an alterna�ve corresponding method.
A minimum of 40 cm of wire is needed a�er the last wire holder bracket, so the wire can be safely secured on the side
of the walkway.
When �ghtening the wire between the brackets (2), take thermal expansion into account. This is especially important in long,
con�nuous systems without extension terminals. Excess tension should be avoided.
Extension of the wire is possible by u�lizing ready factory-assembled terminals. Make the extension by twis�ng the male
terminal completely inside the female terminal. The extension / twis�ng is easier while the wire coming as an extension is s�ll
as a roll.
A�er the last SafeLine wire holder bracket, the end of the
wire is turned 180 degrees and is locked against the roof
walkway with
SafeLine wire ending bracket
improves the safety of the user.
8
When extending the wire from the roof walkway to a roof
or wall ladder, make sure the bend on the wire is smooth
and the glider moves through the bend with ease. A
bracket (2) must be installed as close as possible to the
end of the roof walkway and the beginning of the ladder,
while maintaining smooth wire curve.
Part
Pisko roof walkway
1
SafeLine wire holder bracket
2
3
Hexagon Flange Bolt M8, stainless steel
4
Hex Flange Nut M8, stainless steel
5
Pisko SafeLine stainless steel wire, 8mm
6
Glider end stop for wire holder bracket
7
Wire end protector
8
SafeLine wire ending bracket
(8). This