Instruction for VENSET electrical window opener
Article no.: 111
Please read the enclosed instructions for use and assembly before installation and use. This instruction
describes the installation of the following articles in combination; Opener no. 111, Control panel no. 112 and
Power supply no. 114.
Contents:

1. Advice on security and warnings

2. Guidelines for use

1. Advice on security and warnings
This product complies with all prescribed security regulations. Inappropriate use can cause damage
to users and product.
VENSET cannot be held responsible for any damage on the window or other parts of the building,
whether it is caused by ordinary use, wrong installation, unauthorized maintenance or incorrect use.
Please read the instruction before using the window the first time. It will give you important
directions as to security, use and installation of the window opener, and thus prevent any damage
on both you and the product.
Electrically operated windows may constitute a risk of squeezing body parts within the window's
functioning area. If this window opener is installed somewhere presenting this risk, we recommend
that you replace the standard control panel with a Security panel, article no. 901, which secures that
the opener is only in motion, as long as the button is activated.
If the window opener is controlled automatically, situations may occur where the window opener
does not stop, until the window is completely closed. This can cause a squeezing risk, and these
kinds of controls should not be used, if there is any risk of bodily harm, or if the user cannot visually
make sure that there is no such risk.
This window opener may not be used on windows functioning as emergency exits.
Please keep this instruction hereafter.
2. Guidelines for use
This electrical window opener has been designed for installation in most windows opening outwards.
The window's opening range must be at least 20 cm, and it should open with minimal effort.
The user is responsible for the window opener being properly installed in both frame and sill, and
whether the window is suitable for electrical operation or not.
Install the window opener opposite the
hinges of the window. The window opener
takes up at least 30 cm on the sill.
The distance between the hinges of the
window and the sill, where the window
opener is installed must be at least 40 cm.
On windows wider than 80 cm we
recommend that you install 2 window
openers. Please note that all
measurements are consultative, and that
maximum and minimum measurements
depend on the construction of the window.
600700.1
Copyright 2005, VENSET A/S, VENSET
®
is a registered trademark
1/4
Page

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 111 and is the answer not in the manual?

Questions and answers

Summary of Contents for Venset 111

  • Page 1 Article no.: 111 Please read the enclosed instructions for use and assembly before installation and use. This instruction describes the installation of the following articles in combination; Opener no. 111, Control panel no. 112 and Power supply no. 114. Contents: 1.
  • Page 2 • The VENSET window opener replaces the ordinary operating and locking devices of the window. • The hinges of the window must be oiled to make sure that the window open and close with minimal effort.
  • Page 3 Continuously variable until maximum 12 cm Supply voltage: 24 V DC Power consumpt. in 0,3 A operation Max. power consumption: 0,6 A Engine control: Built-in electrical end stoppers IP level ® Copyright 2005, VENSET A/S, VENSET is a registered trademark Page...
  • Page 4 An electrical window opener is regarded a machine and should not be put into use, until it has been installed correctly according to the directions in the enclosed instructions for use and assembly. Manufacturer: VENSET A/S Nygade 63 Dk-6900 Skjern www.VENSET.com ® Copyright 2005, VENSET A/S, VENSET is a registered trademark Page...

Table of Contents