Com. no.
..................................................
Operator
............................................................................................................................................................
Operating place ........................................................................................................................................................
Swing door drive mechanism
with fire protection rating
SD‑L F (9365x)
Mounting and operating instructions
Pos.
0548-988/12
Original
.................................
2022.01
Construction year ...................

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SD-L F 9365 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Glutz SD-L F 9365 Series

  • Page 1 Swing door drive mechanism with fire protection rating SD‑L F (9365x) Mounting and operating instructions Original Com. no........... Pos........Construction year ....Operator ................................Operating place ................................ 0548-988/12 2022.01...
  • Page 2: Table Of Contents

    SD‑L F (9365x) Mounting and operating instructions TABLE OF CONTENTS GENERAL REMARKS ........................ 5 Target group ........................5 Where to keep these instructions .................. 5 Adresses ......................... 5 Auxiliary tools and service performances ..............6 SAFETY ............................7 Appropriate use ......................7 Safety notices .........................
  • Page 3 SD‑L F (9365x) Mounting and operating instructions COMMISSIONING ........................43 Low-Energy mode ......................45 Servo operation ......................45 Inverse application ....................... 46 Closing sequence control ..................... 47 Interlock operation ...................... 50 6.5.1 Standard interlock (IL Type Safety) ..............50 6.5.2 Hospital interlock (IL Type Hospital) ..............
  • Page 4 SD‑L F (9365x) Mounting and operating instructions 10 SHUT-DOWN .......................... 72 11 DISPOSAL OF THE INSTALLATION ..................73 12 SPARE PARTS .......................... 74 13 OPTIONS ..........................75 13.1 D-BEDIX ........................75 13.1.1 Keys ....................... 75 13.1.2 Symbols ......................75 13.1.3 Operating modes ...................
  • Page 5: General Remarks

    The present instructions have to be kept close to the installation, together with the control book- let! Adresses Distribution agent/ After-sales service Manufacturer Glutz AG Segetzstrasse 13 CH-4502 Solothurn Tel. +41 32 625 65 20 Fax +41 32 625 65 20 www.glutz.com info@glutz.com...
  • Page 6: Auxiliary Tools And Service Performances

    SD‑L F (9365x) Mounting and operating instructions Auxiliary tools and service performances The auxiliary tools and service performances listed hereafter are available, depending on the respective situation and authorization (please ask your distribution agent): • Company portrait • Homepage • E-shop (authorization) •...
  • Page 7: Safety

    SD‑L F (9365x) Mounting and operating instructions SAFETY Appropriate use The swing door drive mechanism with fire protection rating SD-L F (9365x) has been exclusive- ly designed for operating swing doors with fire protection rating. Any other use beyond these application limits is deemed inappropriate and inadmissible! In the event of an inappropriate use of this system, the safety of the user may be jeopar dized and/or the installation be damaged.
  • Page 8 • In order not to create any dangerous squeezing and shearing points, no structural modification must be made within the door surroundings, without prior authorization from Glutz. Further- more, it is important that no objects (such as furniture, pallets, etc.) be placed in the vicinity of the door.
  • Page 9: Service

    A safe and reliable function of the installation can only be guaranteed if it is operated with the original Glutz accessories/spare parts. Glutz declines all responsibility for damages resulting from unauthorized modifications of the installation or from the use of foreign accessories/spare parts.
  • Page 10: Product Description

    SD‑L F (9365x) Mounting and operating instructions PRODUCT DESCRIPTION General remarks The swing door drive mechanism with fire protection rating SD-L F (93650) resp. SD-L F SRP (93651) (special gear for sliding rods pushing function) opens and closes the door leaf via a rod assembly (is not shown in the illustration).
  • Page 11: Standard Application

    SD‑L F (9365x) Mounting and operating instructions Rods Normal rods Sliding rods Sliding rods Drive mechan. pulling function pushing function SD-L F (93650) –   SD-L F SRP (93651) – –  * * Special gear Normal rods RS A Rotating arm B Joint C Rod arms...
  • Page 12: Inverse Application

    SD‑L F (9365x) Mounting and operating instructions Inverse application The swing door drive mechanism SD-L F (9365x) is also appropriate for inversed operation. This particular function can be separately programmed for each drive mechanism. The inverse applica- tion is suitable for smoke extraction from buildings (RWA = smoke and heat exhaust vent solution) as well as for escape and rescue ways.
  • Page 13: Technical Data

    SD‑L F (9365x) Mounting and operating instructions Technical data Drive mechanism Standard SRP (special gear for sliding rods pushing function) Power transmission Normal rods Sliding rods Dimensions drive mechanism Height 95 mm Width 690 mm Depth 120 mm Weight drive mechanism 10,5 kg Ambient temperature -15...+50 °C...
  • Page 14: Maximum Wind-Load Capacity

    SD‑L F (9365x) Mounting and operating instructions Maximum wind-load capacity Normal rods pushing function (lintel mounting) 3000 2900 2800 2700 2600 2500 2400 2300 2200 2100 2000 1000 1100 1200 1300 1400 Clearance width in mm Sliding rods pushing function (lintel mounting) Drive mechanism SRP 3000 2900 2800...
  • Page 15: Mounting

    SD‑L F (9365x) Mounting and operating instructions MOUNTING Preparation Attention: Standard + inverse application It is imperative for the customer to install a door leaf stop piece! This door leaf stop piece prevents the door leaf/drive mechanism from being damaged in the manual operating mode, in case of misuse or vandalism.
  • Page 16: Mounting Versions

    SD‑L F (9365x) Mounting and operating instructions Mounting versions DIN left DIN right Normal rods Normal rods 0548-163 pushing function 0548-163 pushing function Lintel mounting see chapter 4.4.1 Lintel mounting see chapter 4.4.1 Lintel depth 0...240 mm Lintel depth 0...240 mm Drive mechanism 0548-042 alu / 0548-043 inox Drive mechanism...
  • Page 17: General

    SD‑L F (9365x) Mounting and operating instructions General Note for France: Drive units that are used for "smoke extraction" according to NF S 61-937-8 must be mounted according to application sheet P 11.06.15. Warning: The fastening bases must provide sufficient solidity. If necessary they have to be rein- forced by the appropriate means.
  • Page 18 SD‑L F (9365x) Mounting and operating instructions Warning: The drive mechanism must be fastened without torsion and perpendicularly, using all the six fixing holes! Tighten all the six M6 fixing screws (A) with a torque of 10 Nm! A  10 Nm 0548-358 0548-360 MOD Note:...
  • Page 19: Rod Assemblies Rs/Rg

    SD‑L F (9365x) Mounting and operating instructions Rod assemblies RS/RG 4.4.1 Normal rods RS pushing function / Lintel mounting Material: Drive mechanism 0548-042 Covering aluminium Drive mechanism 0548-043 Covering inox incl. fixing set 0548-107 Mounting plate 0548-358 resp. 0548-360 MOD Normal rods 0548-163 Procedure:...
  • Page 20 SD‑L F (9365x) Mounting and operating instructions with mounting plate Options Axle extension (mm) (mm) (mm) Standard 0548-190 3...15 0548-191 3...23 0548-192 3...33 0548-193 3...43 0548-194 3...53 DIN right = as shown DIN left = mirror-inverted Fixing drive Fixing mechanism mounting plate Ø20 ...
  • Page 21 SD‑L F (9365x) Mounting and operating instructions Drive mechanism standard Inverse application 5. Close the door leaf. 5. Separate the rotating arm (C) from the rod arm (B) by loosen the screw (E). 6. Separate the rotating arm (C) from the rod arm (B) by loosen the screw (E).
  • Page 22 SD‑L F (9365x) Mounting and operating instructions Inverse application 12. Let the door leaf be opened by spring power. 13. Using a screwdriver, carefully prize the service cover (C) out of the gearbox housing. 14. By means of a socket wrench 1,5 mm, slightly loosen the locking screw (B) and leave the socket wrench inserted in the locking screw (B).
  • Page 23: Sliding Rods Rg Pulling Function / Lintel Mounting

    SD‑L F (9365x) Mounting and operating instructions 4.4.2 Sliding rods RG pulling function / Lintel mounting Material: Drive mechanism 0548-042 Covering aluminium Drive mechanism 0548-043 Covering inox incl. fixing set 0548-107 Mounting plate 0548-358 resp. 0548-360 MOD Sliding rods 0548-164 650 mm incl.
  • Page 24 SD‑L F (9365x) Mounting and operating instructions with mounting plate DIBt Lintel Min. width Max. Options Axle ex- che- depth door leaf door leaf without/ tension 46 mm 46 mm 18 mm 18 mm cked without/with opening with Sliding Sliding Sliding Sliding FLATSCAN...
  • Page 25 SD‑L F (9365x) Mounting and operating instructions Drive mechanism standard Inverse application 6. Close the door leaf. 6. Mount the drive mechanism. 7. Prior to the installation of the drive unit: 7. Open the door leaf (max. 115°). Screw down the lever arm (D) on the drive unit  Tightening moment 25 Nm.
  • Page 26: Sliding Rods Rg Pushing Function / Lintel Mounting

    SD‑L F (9365x) Mounting and operating instructions 4.4.3 Sliding rods RG pushing function / Lintel mounting Material: Drive mechanism SRP 0548-044 Covering aluminium Drive mechanism SRP 0548-045 Covering inox incl. fixing set 0548-107 Mounting plate 0548-358 resp. 0548-360 MOD Sliding rods 0548-164 650 mm incl.
  • Page 27 SD‑L F (9365x) Mounting and operating instructions with mounting plate DIBt Lintel Min. width door Max. door leaf Options Axle ex- che- depth leaf opening angle tension 18 mm 46 mm cked (mm) (mm) (°) (mm) Sliding Sliding bolt bolt -30...0 ...
  • Page 28 SD‑L F (9365x) Mounting and operating instructions Drive mechanism standard Inverse application 7. Close the door leaf. 7. Open the door leaf (max. 115°). 8. Screw down the lever arm (D) on the drive unit  8. Slide the open position stop piece (B) into the sliding Tightening moment 25 Nm.
  • Page 29: Adjusting The Pre-Stressing Of The Closing Spring

    SD‑L F (9365x) Mounting and operating instructions Adjusting the pre-stressing of the closing spring Upon delivery, the closing spring is pre-stressed for a measure X* = 26 mm. To ensure a safe and optimal operation of the swing door drive mechanism, the correct pre-stressing must be adjusted for the closing spring (by means of the setting screw).
  • Page 30 SD‑L F (9365x) Mounting and operating instructions Inverse application EN class EN 3 EN 4 EN 5 EN 6 Width of door leaf 950 mm 1'100 mm 1'250 mm 1'400 mm Normal rods Measure X * 40 mm 36 mm 31 mm 27 mm Sliding rods pulling function...
  • Page 31: Setting The Forceful Closing Function

    SD‑L F (9365x) Mounting and operating instructions Setting the forceful closing function Note: The accelerating function (forceful closing) is only activated for the standard drive mechanism. 4.6.1 Forceful closing cushioning While an installation is in the state without mains power or in the operating mode MANUAL, the motor acts as an attenuator, thus guaranteeing a constant closing speed until the forceful closing range is reached.
  • Page 32: Forceful Closing Range

    SD‑L F (9365x) Mounting and operating instructions 4.6.2 Forceful closing range Upon delivery from the factory, the activation of the accelerating function (forceful closing) is pre- set (i.e. it intervenes approx. 5° before reaching the closed position). Under normal conditions, it will not be necessary to change the default setting! However, in cases where in the de-energized state or in the operating mode MANUAL the door leaf fails to be reliably engaged in the door lock, the activation point of the accelerating function (forceful closing) can be shifted (by means of a...
  • Page 33: Mechanical Closing Sequence Regulator

    SD‑L F (9365x) Mounting and operating instructions Mechanical closing sequence regulator Attention: For any 2 leaves fire protection door, it is compulsory to mount the integrated closing sequence regulator SD-L F ISR (0548-154), homologated by the "Deutsche Institut für Bautechnik" Berlin (DIBt). For any 2 leaves door with escape way function, a driver flap (supplied by customer) must be provided, unless this function is guaranteed by the locking system.
  • Page 34: Electrical Connections

    SD‑L F (9365x) Mounting and operating instructions ELECTRICAL CONNECTIONS Power supply Warning: Before working on the drive mechanism, make sure that the mains cable is voltage- free! The mains supply line including mains plug (with respective protection) has to be provided by customers.
  • Page 35 SD‑L F (9365x) Mounting and operating instructions Connect the mains supply cable as illustrated (see also wiring diagram E4-0141-713_Glutz in the appendix). Mount the side cover extensions. Mount the side covers. Program selector closer to the door hinges Strain relief Side cover extension Mounting plate Program selector...
  • Page 36: Cable Layout

    SD‑L F (9365x) Mounting and operating instructions Cable layout 5.2.1 Lintel mounting   (614) 0548-988/12 0548-988-11---20_2022.01.indd Page 36 of 87...
  • Page 37: Fire Protection Pcb

    SD‑L F (9365x) Mounting and operating instructions Fire protection PCB The fire protection PCB (red) provides the following connections: X103 Manul triggering (for manual alarm); Fire alarm confirmation button X104 Fire detectors (max. 3 pcs mounted in series) Do not use in France! X105 Optional connector (for connecting of one addi- tional optional PCB)
  • Page 38 SD‑L F (9365x) Mounting and operating instructions Diagnostics: Fire alarm central Manual triggering The identified fire protection PCB is displayed as Smoke detector/Thermal switch follows in the diagnostic menu: no response ------------------------------------------------------------------------------------------------------------ Short-circuit R0 Relay PCB with DIP switch on position Wire rupture Addr0 --------------------------------------------------------------------------------------------...
  • Page 39: External Elements

    SD‑L F (9365x) Mounting and operating instructions External elements Mount all the required control and safety elements at their respective place. Lead the cables of the elements up to the drive mechanism (by customers). Connect the cables according to the diagram E4-0141-713_Glutz (in the appendix). Note: If an electric lock is provided, its connection rating is 24 VDC and max.
  • Page 40: Motorized Lock

    SD‑L F (9365x) Mounting and operating instructions Motorized lock The swing door drive mechanism and its control unit are always configured as Master. All the commands are transmitted to this control unit. The latter then unlocks/locks the motorized lock. Attention: The motorized lock must be homologated together with the fire safety profile system! Functional performance: Opening command...
  • Page 41: Motorized Lock With Own Evaluation Control

    SD‑L F (9365x) Mounting and operating instructions 5.5.2 Motorized lock with own evaluation control The motorized lock is equipped with an own evaluation control (either integrated or external). The swing door drive mechanism is configured as the Master unit and transmits a voltage free impulse for control unit of the motorized lock for relasing the latter.
  • Page 42: Motorized Lock With Separate Evaluation Control/Power Pack

    SD‑L F (9365x) Mounting and operating instructions 5.5.3 Motorized lock with separate evaluation control/power pack The motorized lock is equipped with a separate evaluation control and a separate power pack ensuring the power supply. The swing door drive mechanism is configured as the Master and transmits a voltage free impulse to the control unit of the motorized lock for releasing the latter.
  • Page 43: Commissioning

    SD‑L F (9365x) Mounting and operating instructions COMMISSIONING Warning: During the teach-in procedure (which must only be carried out by experts), the safety devices (radar, sensors, ...) are switched off! Before initiating the teach-in procedure, it is important to make sure that neither persons nor objects remain within the danger area of the moving door leaf, in order to avoid injuries or damages! Attention:...
  • Page 44 SD‑L F (9365x) Mounting and operating instructions Adjust the opening speed Vo and validate by means of OK. Adjust the closing speed Vc and validate by means of OK. If desired: Invers Program the inverse application (spring-powered opening) and validate it by pressing OK.
  • Page 45: Low-Energy Mode

    SD‑L F (9365x) Mounting and operating instructions Note: A renewed teach-in procedure (Teach) is required if: • the spring tension has been changed • the leaf weight has been changed • the type of rod assembly has been changed • the opening angle Ao has been changed •...
  • Page 46: Inverse Application

    SD‑L F (9365x) Mounting and operating instructions Inverse application Attention: The starting delay TDelay must be > 0 s and the relieving force during unlocking FDelay must be adjusted in accordance. Software configuration: • Activate the parameter Inverse. Attention: the motor connector must not be plugged in the same manner as for the standard drive mechanism.
  • Page 47: Closing Sequence Control

    SD‑L F (9365x) Mounting and operating instructions Closing sequence control For 2 leaves installations, the closing sequence control determines the order in which the door leaves are opened and closed. For the opening procedure, the earlier door leaf (Master leaf) is the first one to be opened, whereas for the closing procedure the delayed door leaf (Slave leaf) is the first one to be closed.
  • Page 48 SD‑L F (9365x) Mounting and operating instructions Function: The first door leaf to be put in motion for the opening procedure is the Master; by means of DubleD, this leaf is configured as MastrA. Its partner is the Slave, which is configured as SlaveA by means of DubleD.
  • Page 49 SD‑L F (9365x) Mounting and operating instructions Procedure: Connect both control units by means of the CAN cable 0383-194/07 (by plugging it into the socket X117). Note: The respective control and safety elements are connected to the corresponding drive mechanism. Take the Master drive mechanism into operation (see chapter 6).
  • Page 50: Interlock Operation

    SD‑L F (9365x) Mounting and operating instructions Interlock operation To create an interlock, two consecutive doors are electrically connected (by means of CAN cable) and configured as an interlock unit during the commissioning. Warning: If the interlock is made of fire-safety doors, a smoke detector and a manual triggering button must be installed for each door! The Interlock operation may only be used for single door leaf systems! 6.5.1...
  • Page 51 SD‑L F (9365x) Mounting and operating instructions Procedure: Exterior side Note: Both installations must be plugged Side A into resp. out of the same power supply. Connect both control units by means of the CAN cable (by plugging it into the socket Side B X117).
  • Page 52: Adhesive Labels

    (CAI) con contacto lib senza potenziale della centralina 24 V / 48 V potencial 8.2 k 8.2 k italiano español DIN18650 1 DIN18650 1 B3-0548-558 FSA/GK Glutz SD-L F FSA/GK Glutz SD-L F SRP 0548-988/12 0548-988-11---20_2022.01.indd Page 52 of 87...
  • Page 53: Mount The Drive Mechanism Covering

    SD‑L F (9365x) Mounting and operating instructions Mount the drive mechanism covering Material: Covering 0548-400 Aluminium Covering accessories 0548-143 Aluminium Covering 0548-303 Stainless steel Covering accessories 0548-115 Stainless steel Procedure: Mount the covering and the accessories as shown in the illustration. 0610-503 0548-364 Alu 0548-400 Alu...
  • Page 54: Control

    SD‑L F (9365x) Mounting and operating instructions CONTROL Main switch The drive mechanism is supplied with a built-in main switch (A). This main installation switch enables you to disconnect the power supply from the drive mechanism. The door leaf then is closed from any position by means of spring power (Invers = spring opening, unless the door leaf has not been locked).
  • Page 55: Operating Modes

    SD‑L F (9365x) Mounting and operating instructions Operating modes The following operating modes can be enabled by means of the program selector: AUTOMATIC Automatic opening via the opening elements inside/outside + Key. Automatic closing upon expiration of the adjustable hold-open time. NIGHT The door leaf can only be opened via the opening element Key (key-operated siwtch outside).
  • Page 56: Motional Parameters (Parameter)

    SD‑L F (9365x) Mounting and operating instructions 7.4.1 Motional parameters (PARAMETER) Parameter Description Setting range Default Opening speed (velocity open) 0...14 (5...50°/s) Closing speed (velocity close) 0...14 (5...50°/s) TOEx Hold-open time opening element inside/outside (time hold opening element inside/outside) 0...60 s TKey Hold-open time Key (time hold opening element Key) 0...180 s...
  • Page 57: Configuration (Config)

    SD‑L F (9365x) Mounting and operating instructions 7.4.2 Configuration (CONFIG) Parameter Description Setting range Default Servo Support for manual push to open The key opens automatically. Five-position adjustment, depending on the width and weight of the door leaf. 1...5 Only usable if DubleD = OFF, Invers = OFF and InterL = OFF. APuGo Triggering angle Push&Go (angle push&go) Only usable if Servo = OFF.
  • Page 58: Installations With Multiple Door Leaves (Double Door)

    SD‑L F (9365x) Mounting and operating instructions PSKIZe Zero position of the program setting (operating mode); fixed program position that can only be changed by NO ACT NO ACT means of the terminals on the control unit (program selector key in the side cover inactive). PSOPEN Use for external program switch (only four terminals) or for controlling the program positions via the termi- PSHAND...
  • Page 59: Menu Navigation

    SD‑L F (9365x) Mounting and operating instructions 7.4.4 Menu navigation 0548-988/12 0548-988-11---20_2022.01.indd Page 59 of 87...
  • Page 60 SD‑L F (9365x) Mounting and operating instructions On the 1st level, the following information is shown on the display: 1st display line: The door position is represented by means of the arrows (><). Alternatively, the motion-relevant opening and safety signals are displayed. The double hash signs (##) indicate that the door is locked.
  • Page 61 SD‑L F (9365x) Mounting and operating instructions DIAGNOSTICS Diagnostic tools • K-I-O-R-S-E shows the inputs KEY (K), OEI (I), OEO (O), SER (R), SES (S), EMY (E). (+) stands for active, (-) for inactive. • 5.1A 95° shows the motor current and the door opening angle. •...
  • Page 62 SD‑L F (9365x) Mounting and operating instructions BLOCK/UNBLOC Lock/unlock the joystick • BLOCK Lock the joystick. For a temporary unlocking, press OK for more than 1 second. 60 seconds after the last joystick actuation, the joystick is automatically relocked. • UNBLOC Permanent unlocking of the joystick.
  • Page 63: Service

    SD‑L F (9365x) Mounting and operating instructions SERVICE A regular service (maintenance/checking) is absolutely indispensable in order to guarantee a safe operation and long lifetime of the installation. The service must be carried out at least once a year: • by a expert (according to the following checklist) •...
  • Page 64: Service For Pedestrian Doors

    Rating plate, arrow sticker, glass sticker, etc. existing? Control booklet existing and completed? Only for redundant drive mechanisms. Glutz cleans all the elements of the installation provided this is necessary for the function of the installation. A general cleaning of the installation is not planned. 0548-988/12 0548-988-11---20_2022.01.indd...
  • Page 65: Fundamental Checking

    SD‑L F (9365x) Mounting and operating instructions Fundamental checking Warning: Switch the main installation switch off on the drive mechanism! Dismount the covering of the drive mecha- nism. Check all the cable connections. Normal rods: Separate the rotating arm (A) from the rod arm (B) by loosen the screw (C).
  • Page 66: Troubleshooting

    SD‑L F (9365x) Mounting and operating instructions TROUBLESHOOTING Warning: Electrocution hazard! Before working on any live elements, pull out the mains plug respectively switch off the main installation switch! If a malfunction occurs which might be detrimental to the safety of the users, and which cannot be eliminated without delay, the operator must be informed and if requi- red the installation shall be taken out of operation.
  • Page 67: Drive Mechanism

    SD‑L F (9365x) Mounting and operating instructions 9.1.1 Drive mechanism Description Cause Elimination Checking time Reaction E01 01 Encoder Channel A lost Check the encoder connection. During run Check the motor cable. Channel B lost The sense of rotation of the motor is not in Channels A + B lost compliance with the rod assembly.
  • Page 68: Safety Elements

    SD‑L F (9365x) Mounting and operating instructions 9.1.3 Safety elements Description Cause Elimination Checking time Reaction E20 01 SER Test SER Test signal unsuccessful SER short-circuit to the earth. Prior to closing Check the cabling of the sensor or the jumper.
  • Page 69: Malfunction Without Error-No

    SD‑L F (9365x) Mounting and operating instructions Malfunction without error-no. In some cases, it will be technically impossible to display an "irregular functioning" of the instal- lation by a definite error number. An alleged error may by all means also be due to "correct" cau- ses.
  • Page 70: Software Update Via Usb

    SD‑L F (9365x) Mounting and operating instructions Software update via USB A software update of the SD-L F (9365x) control unit can be easily and rapidly achieved by means of an USB memory stick. Note: Not all the USB memory sticks can be used. We thus recommend a previous testing of their function together with the SD-L F (9365x).
  • Page 71: Procedure

    SD‑L F (9365x) Mounting and operating instructions 9.3.2 Procedure Switch off the main installation switch on the SD-L F (9365x). Plug the USB stick into the control unit  socket X118. X118 Switch on the main installations  switch on the SD-L F (9365x). The software download takes approx.
  • Page 72: Shut-Down

    SD‑L F (9365x) Mounting and operating instructions SHUT-DOWN No particular measures need to be taken for de-commissioning the installation. If the swing door drive mechanism will not be used during at least 1 month, it is recommended to pull out the mains plug. For taking the installation back into operation, all you have to do is to plug in the mains cable and select the operating mode.
  • Page 73: Disposal Of The Installation

    SD‑L F (9365x) Mounting and operating instructions DISPOSAL OF THE INSTALLATION An ecologically acceptable disposal of the installation is ensured if the different materials are separated and recycled. No particular measures are required for the protection of the environment. However, the relevant legal prescriptions applicable for the installation site have to be complied with! 0548-988/12 0548-988-11---20_2022.01.indd...
  • Page 74: Spare Parts

    SD‑L F (9365x) Mounting and operating instructions SPARE PARTS Article No. Description Remark 0548-116 Drive module 0548-117 Drive module SRP 0548-204 Switch support complete 0548-107 Fixing set 0548-358 Mounting plate Option 0548-360 Mounting plate Mod. Option 0548-141 Control unit complete (incl. fire protection PCB) 0548-113 Encoder cable, reference switch cable, screws 0548-215...
  • Page 75: Options

    SD‑L F (9365x) Mounting and operating instructions OPTIONS 13.1 D-BEDIX The different operating modes can be directly enabled by means of the D-BEDIX. In addition, it provides easy programming of the most impor- tant door settings. The operating modes, menu settings as well as possible errors are displayed in a clearly ar- ranged synopsis.
  • Page 76: Operating Modes

    SD‑L F (9365x) Mounting and operating instructions 13.1.3 Operating modes With the D-BEDIX, the following operating modes can be selected by means of the corresponding symbols: AUTOMATIC Automatic operation. The installation can be locked. NIGHT The installation is locked . As opening commands, only the key-operated impulse switch is accepted.
  • Page 77: Menu Level

    SD‑L F (9365x) Mounting and operating instructions 13.1.5 Menu level Short and simultaneous actuation of both arrow keys (=access to the menu level). Select the desired menu item bymeans of the arrow key. Confirm by means of the OK key. Display Description PARAMETER...
  • Page 78: Setting Examples

    SD‑L F (9365x) Mounting and operating instructions 13.1.6 Setting examples Changing the operating mode Select the desired symbol by means of the arrow key (symbol starts flashing). Confirm with the OK key (frame/bar switch over). Preselecting the operating mode An overriding switch is active and determines the operating mode (only the selection frame is visible, the bar underlines the preselected operating mode).
  • Page 79: Error Display

    SD‑L F (9365x) Mounting and operating instructions Parameters (hold-open timeday) Short simultaneous actuation of the arrow keys (= access to the menu level). By means of the arrow key, select TOEx. Confirm with the OK key. By means of the arrow key, change the value. Confirm with the OK key.
  • Page 80: Kombi-D-Bedix

    Cylinder: to be supplied by customers If this lockout is enabled, all the keys are shortly lit (as a confirmation of the lockout). 0635-148/04 0635-148/02 Glutz 81075 (8 x 45°) Glutz 81175 (8 x 45°) KABA 1514 KESO 21.214.040 SEA 1.043.0...
  • Page 81: Open Position Stop Piece Integrated In The Drive Mechanism

    SD‑L F (9365x) Mounting and operating instructions 13.3 Open position stop piece integrated in the drive mechanism Attention: Standard + inverse application It is imperative for the customer to install a door leaf stop piece! This door leaf stop piece prevents the door leaf/drive mechanism from being damaged in the manual operating mode, in case of misuse or vandalism.
  • Page 82: Connection Plate For Wooden Door Leaf (Normal Rods)

    SD‑L F (9365x) Mounting and operating instructions 13.4 Connection plate for wooden door leaf (normal rods) The connection plate is mounted below the door connection angle of the normal rod assembly and screwed down by means of countersunk chipboard screws 5 x 30. Packing unit 0549-115 Connection plate...
  • Page 83: Continuous Covering

    SD‑L F (9365x) Mounting and operating instructions 13.5 Continuous covering For 2 leaves installations, the two drive mechanisms can be optically connected by inserting an intermediate covering piece. Note: A fire alarm is displayed by the red LED in the side cover. This LED must be visible on one of the two drive mechanisms! Set with drive mechanism covering 1,9 m Alu 0548-214...
  • Page 84: Optional Pcbs

    SD‑L F (9365x) Mounting and operating instructions 13.6 Optional PCBs All the optional PCBs are plugged into the control unit via a universal connector. A maximum number of two optional PCBs can be combined. Attention: All optional PCBs must only be plugged into/removed from the control unit after the dive unit has been disconnected from the power supply source! 13.6.1 Relay PCB...
  • Page 85: Radio Pcb

    SD‑L F (9365x) Mounting and operating instructions 13.6.2 Radio PCB A radio control PCB can be plugged into the control of the drive mechanism. Using a hand-held radio transmitter/radio transmitter/radio code lock, this PCB can be programmed with a code, upon which the drive mechanism can be controlled via this element.
  • Page 86: Lzr-Flatscan

    SD‑L F (9365x) Mounting and operating instructions 13.7 LZR‑FLATSCAN In the event of swing doors, the FLATSCAN is mounted on the moving leaf, on the upper leaf cor- ners (as close as possible to the secondary closing edge). The FLATSCAN can only be used in pairs! Master and Slave are connected among each other (see wiring diagram in the appendix).
  • Page 87: Appendix

    SD‑L F (9365x) Mounting and operating instructions APPENDIX The following documents are added as an appendix to this instructions: Wiring diagram ....................E4-0141-713_Glutz Wiring diagram Fire protection PCB ..............E4-0141-714_Glutz Wiring diagram Fire protection PCB "France" ............E4-0141-718_Glutz Wiring diagram motorised locks ................E4-0142-180_Glutz 0548-988/12 0548-988-11---20_2022.01.indd Page 87 of 87...