schmalenberger FLUVO Control NT Operator's Manual

schmalenberger FLUVO Control NT Operator's Manual

Control box

Advertisement

Control Box Control NT
Operator's Manual
GB
Translation of the original

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLUVO Control NT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmalenberger FLUVO Control NT

  • Page 1 Control Box Control NT Operator’s Manual Translation of the original...
  • Page 2: Table Of Contents

    Please drop these devices off at public collection points provided for that purpose when you have finished using them. Subject to technical changes Schmalenberger GmbH + Co. KG Control box Control NT D-72072 Tübingen / Germany...
  • Page 3: Introduction

    Before beginning installation and service work, the power supply connection must be switched off. • The device does not contain any components that require servicing by the user. Subject to technical changes Control box Control NT Schmalenberger GmbH + Co. KG Version: 27248 - C D-72072 Tübingen / Germany...
  • Page 4: Functional Description

    After 5 seconds the LED flashes 1x per second -> control box is ready for operation Continuously lit: control box running SERVICE Flashing for malfunction Subject to technical changes Schmalenberger GmbH + Co. KG Control box Control NT D-72072 Tübingen / Germany Version: 27248 - C...
  • Page 5: Runtime Limiting, Time Lag Relais

    • Disconnect the power to the control unit, remove the bridge and reconnect the piezo button. Subject to technical changes Control box Control NT Schmalenberger GmbH + Co. KG Version: 27248 - C D-72072 Tübingen / Germany...
  • Page 6: Current Monitoring

    When using a converter box 3.0, additional sensor buttons can be connected. This func- tionality can be activated via DIP switch 4. (see chap. 4) Subject to technical changes Schmalenberger GmbH + Co. KG Control box Control NT D-72072 Tübingen / Germany...
  • Page 7: Function 2-Way Valve (Besgo)

    See connection diagram, section 4.6.4 Also observe the Operator's Manual 27251 "Converter Box 3.0" 2.9.2 Function 2-way valve (BESGO)  see supplement 27265 Subject to technical changes Control box Control NT Schmalenberger GmbH + Co. KG Version: 27248 - C D-72072 Tübingen / Germany...
  • Page 8: Wall Installation With Dimensions

    Supply line Mains / Pump cable ø7-13mm 5x cable screw connection Plug nippel ø3,6mm Feedback and Control line Hose connection cable ø3,5-7mm Subject to technical changes Schmalenberger GmbH + Co. KG Control box Control NT D-72072 Tübingen / Germany Version: 27248 - C...
  • Page 9: Connections And Settings

    Connection Terminals for Control and Feedback Contacts Pump ON Malfunction Enable Imax = 30mA Start GND 24V Stop Floating switching contact Subject to technical changes Control box Control NT Schmalenberger GmbH + Co. KG Version: 27248 - C D-72072 Tübingen / Germany...
  • Page 10: Feedback Contact

    Potentiometer for setting the runtime (1 - 60 minutes) CONFIG DIP switches for setting the device address and switch functio- nality. See section 4.4. Subject to technical changes Schmalenberger GmbH + Co. KG Control box Control NT D-72072 Tübingen / Germany Version: 27248 - C...
  • Page 11: Terminal Compartment Disconnection

    The terminal chamber disconnect is inserted and can be removed for easier wiring as follows: Terminal compartment disconnection Installation is in the opposite order. Subject to technical changes Control box Control NT Schmalenberger GmbH + Co. KG Version: 27248 - C D-72072 Tübingen / Germany...
  • Page 12: Configuration Using Dip Switches

    Provide a 0.03 A FI circuit breaker in the mains power supply line. • For the fuse see the identification on the cover of the terminal box. Subject to technical changes Schmalenberger GmbH + Co. KG Control box Control NT D-72072 Tübingen / Germany Version: 27248 - C...
  • Page 13: Connection Diagrams

    The operating voltage between L1 and N is 230V! Higher voltages can destroy the device. Smaller voltages can lead to malfunctions. Subject to technical changes Control box Control NT Schmalenberger GmbH + Co. KG Version: 27248 - C D-72072 Tübingen / Germany...
  • Page 14: Connection Diagram 3~ Mains 400V Ac

    The operating voltage between L1 and N is 230V! Higher voltages can destroy the device. Smaller voltages can lead to malfunctions. Subject to technical changes Schmalenberger GmbH + Co. KG Control box Control NT D-72072 Tübingen / Germany Version: 27248 - C...
  • Page 15: Connection Diagram 3~ Mains 230V Ac

    The operating voltage between L1 and N is 230V! Higher voltages can destroy the device. Smaller voltages can lead to malfunctions. Subject to technical changes Control box Control NT Schmalenberger GmbH + Co. KG Version: 27248 - C D-72072 Tübingen / Germany...
  • Page 16: External Sensor Button Connection Diagram

    Rotary switch Feedback via DOUT1-4 MODE A DOUT1 - Pump ON DOUT2 - Fault DOUT3 - Enable Subject to technical changes Schmalenberger GmbH + Co. KG Control box Control NT D-72072 Tübingen / Germany Version: 27248 - C...
  • Page 17: Technical Data

    0,5 - 1,5 qmm cross-section flexible with end splice 0,5 - 1,0 qmm OVERCURRENT MONITORING IEC 60947-4-1 CLASS 10 Subject to technical changes Control box Control NT Schmalenberger GmbH + Co. KG Version: 27248 - C D-72072 Tübingen / Germany...
  • Page 18: Nameplate

    External / piezo BESGO = 2-way valve HW = Hardware version SW = Software/firmware version SN = Serial number Subject to technical changes Schmalenberger GmbH + Co. KG Control box Control NT D-72072 Tübingen / Germany Version: 27248 - C...
  • Page 19: Service / Notes

    Service / notes When What Subject to technical changes Control box Control NT Schmalenberger GmbH + Co. KG Version: 27248 - C D-72072 Tübingen / Germany...
  • Page 20 +49 (0)7071 70 08 - 10 Im Schelmen 9 - 11 Internet: www.fluvo.de D-72072 Tübingen / Germany E-mail: info@schmalenberger.de © 2018 Schmalenberger GmbH + Co. KG; All rights reserved Manual is subject to changes Control box Control NT Version: 27248 - C...