Portable oxygen system

Advertisement

Quick Links

Your Sky-Ox
®
Portable Oxygen System
Use & Care Guide
Aerox
Aviation Oxygen Systems, LLC
®
12871 Trade Way Drive, Suite 8
Bonita Springs, FL 34135
www.aerox.com
info@skyox.com
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Sky-Ox and is the answer not in the manual?

Questions and answers

Summary of Contents for Aerox Sky-Ox

  • Page 1 Your Sky-Ox ® Portable Oxygen System Use & Care Guide Aerox Aviation Oxygen Systems, LLC ® 12871 Trade Way Drive, Suite 8 Bonita Springs, FL 34135 www.aerox.com info@skyox.com Page 1...
  • Page 2: Table Of Contents

    Thank You ® Thank you for investing in a Sky-Ox Portable System from Aerox Aviation Oxygen Systems. Your Portable Oxygen System, including the Click & Breath™ regulator introduced in 2008, is designed, engineered, and manufactured to the highest quality standards in the industry and we are committed to serving your needs with equally high customer service.
  • Page 3: System Components

    Do not drop and protect the unit from shock or damage. Keep away from anyone who may not be familiar with the hazards of its improper use or handling. Maintain equipment using an Aerox-Approved FAA Authorized Aviation Oxygen Repair Station. Follow their recommendations on proper use.
  • Page 4: Operating Instructions

    Sky-Ox Portable Oxygen Systems are shipped with two or four pendent style Oxysaver® Cannulas (see photo) and one mask. Each Sky-Ox® cannula comes complete and assembled with a connector, flow-indicator, and pendant cannula. The pendent style offers more freedom plus comfort and the ability to drink water, coffee, a can of soda, or to eat a sandwich .
  • Page 5 1.5 LPM - 15,000 FT. .5 LPM - 15,000 FT. 2.0 LPM - 20,000 FT. .6 LPM - 18,000 FT. 2.5 LPM - 25,000 FT. Aerox Aviation Oxygen Systems, LLC ® 12871 Trade Way Drive, Suite 8 Bonita Springs, FL 34135 www.aerox.com...
  • Page 6 If the indicator is green, it indicates that oxygen is flowing from the cylinder to the cannula. Sky-Ox® Flow Indicator (showing no-oxygen flow) A cannula (either a pendent or a mustache style) can be used only up to 18,000 ft.
  • Page 7: Refilling The Aluminum Cylinder

    Grip (4) (see figure below) between the On/Off Valve and the Regulator. (Turn Grip Counterclockwise. The valve is a standard fitting for oxygen (CGA 540) and no tools are required. Aerox recommends using only aviator grade oxygen. The oxygen supplier is responsible for testing their storage and charging systems. Aerox Aviation Oxygen Systems, LLC ®...
  • Page 8: Refilling The Steel Cylinder

    Regulator (5). The grip is located to the left of the On/Off Valve in the above illustration. After refilling, make sure this Regulator (5) is securely fastened - hand tightening (4) only needed. - No wrench is needed. Aerox Aviation Oxygen Systems, LLC ®...
  • Page 9 After Using System 1. When finished using the Sky-Ox® portable oxygen system, turn the Flow Adjustment Control ( 7 ) to zero (0). 2. Turn the On/Off Valve (3) off by turning the knob clockwise. 3. If you have removed all of the quick disconnect units, reinsert one to bleed- off the oxygen still in the line.
  • Page 10: Oxygen Cylinder Maintenance

    • A fully depleted oxygen cylinder may require a dry air or nitrogen purge to remove moisture. • Table 2 Provides Hydrostatic Test and Service Life requirements for listed cylinders. Aerox Aviation Oxygen Systems, LLC ® 12871 Trade Way Drive, Suite 8 Bonita Springs, FL 34135 www.aerox.com...
  • Page 11 Charge the oxygen cylinder as discussed in Initial Filling. Upon completion of filling operations, check for leakage using a liquid leak detector or a mild soapy water formula. Aerox Aviation Oxygen Systems, LLC ® 12871 Trade Way Drive, Suite 8 Bonita Springs, FL 34135 www.aerox.com...
  • Page 12 Note that certain state, federal and international regulations may apply to the handling and maintenance of oxygen cylinders based on installation and application. Further information regarding oxygen cylinder maintenance and use is available upon request. Aerox Aviation Oxygen Systems, LLC ® 12871 Trade Way Drive, Suite 8 Bonita Springs, FL 34135 www.aerox.com...
  • Page 13: Care Of Your Portable Oxygen System

    Do Not Use alcohol which may damage the unit. DO NOT SUBMERGE THE CANNULA. Replacement of the cannula is recommended after 3 years or 200 hours of use. Aerox Aviation Oxygen Systems, LLC ® 12871 Trade Way Drive, Suite 8 Bonita Springs, FL 34135 www.aerox.com...
  • Page 14 Oxygen Content By System Model When Full (2000 psi) Model Number Liters SK-11-50 1415 SK-11-40 1132 SK-12-24 SK-11-20 SK-12-15 SK-12-9 SK-12-6 Aerox Aviation Oxygen Systems, LLC ® 12871 Trade Way Drive, Suite 8 Bonita Springs, FL 34135 www.aerox.com info@skyox.com Page 14...
  • Page 15 For more information on Sky-Ox Products, visit us at www.aerox.com/sky-ox/ Oxysaver®, Aerox®, Sky-Ox®, and Click-a-Breath® are registered trademarks of Aerox Aviation Oxygen Systems, LLC. © Aerox Aviation Oxygen Systems, LLC 2022 Aerox Aviation Oxygen Systems, LLC ® 12871 Trade Way Drive, Suite 8 Bonita Springs, FL 34135 www.aerox.com...