1. Users are required to read the operation manual completely and carefully before installation or
operation.
2. The product should be installed and pre-operated by well-trained persons. All power supplies
must be turned off during the installation work, remember not to operate with power on.
3. All the instruction marked with sign
injuries might occur.
4. For perfect operation and safety, it is prohibited that using extension cable with multi-outlet
for power connection.
5. When connecting the power cord, it must be determined that the operating voltage conforms
to the rated voltage value specified in the product identification.
6. Don' t operate in direct sun light, outdoors area and where the room temperature is over 45°C
or below 0°C.
7. Please avoid operating near the heater at dew area or at the humidity below 10% or above
90%.
8. Don't operate in area with heavy dust, corrosive substance or volatile gas.
9. Avoid power cord being applied by heavy objects or excessive force, or over bend.
10. The earth wire of power cord must be connected to the system ground of the production plant
by proper size of conductions and terminals. This connection should be fixed permanently.
11. All the moving portions must be prevented to be exposed by the parts provided.
12. Turing on the machine in the first time, operate the sewing machine at low speed and check
the correct rotation direction.
13. Turn off the power before the following operation:
1. Connecting or disconnecting any connectors on the control box or motor.
2. Threading needle.
3. Raising the machine head.
4. Repairing or doing any mechanical adjustment.
5. Machines idling.
14. Repairs and high level maintenance work should only be carried out by electronic technicians
with appropriate training.
15. All the spare parts for repair must be provided or approved by the manufacturer.
16. Don't use any objects or force to hit or ram the product.
Guarantee Time
Warranty period of this product is 1 year dated from purchasing, or within 2 years from
ex-factory date.
Warranty Detail
Any trouble found within warranty period under normal operation, it will be repaired free of
charge. However, maintenance cost will be charged in the following cases even if within
warranty period:
1. Inappropriate use, including: wrong connecting high voltage, wrong application,
disassemble, repair, modification by incompetent personnel, or operation without the
precaution, or operation out of its specification range, or inserting other objects or liquids
into the product.
2. Damage by fire, Earth quake, lighting, wind, flood, salt corrosive, moisture, abnormal
power voltage and any other damage cause by the natural disaster or by the inappropriate
environments.
3. Dropping after purchasing or damage in transportation by customer himself or by
customer's shipping agency
* We make our best effort to test and manufacture the product for assuring the quality.
However, it is possible that this product can be damaged due to external magnetic
interference and electronic static or noise or unstable power source more than expected;
therefore the grounding system of operate area must guarantee the good earth and it's also
recommended to install a failsafe device (Such as residual current breaker).
Safety Instruction
must be observed or executed; otherwise, bodily

Advertisement

loading

Summary of Contents for Baoyu GT-288E

  • Page 1 Safety Instruction 1. Users are required to read the operation manual completely and carefully before installation or operation. 2. The product should be installed and pre-operated by well-trained persons. All power supplies must be turned off during the installation work, remember not to operate with power on. 3.
  • Page 2: Key Description

    1 Button Displays and Operating Instructions 1.1 Key Description Name Indicate If click, enter or exit the user parameter setting interface. Function Parameter If long-press, it will switch to the password input interface. Enter the correct password, Edit press S key to confirm, you can enter the advanced parameter setting interface. For the content of the selected parameters check and save: after select parameter press Setting Parameter this key to check and modify operation, after modified parameter value press this key...
  • Page 3: Auxiliary Function

    1.2 Auxiliary Function 1.2.1 Debugging Mode On the main interface, long-press S key to enter to the debugging parameter interface. P92 correct the electrical angle of motor, P72 up needle position adjustment, P129 back-tacking step motor zero-point correction, P74 tacking stitch length compensation and P75 back-tacking stitch length compensation parameter setting. 1.2.2 Tight Seam Mode Editing On the main interface, long-press tight seam key to display "F-1"...
  • Page 4: User Parameter

    setting is completed, press the S key to confirm. Short press P key to exit to the main interface. 1.2.6 Pattern Constant-stitch Sewing Editing In the multi-segment sewing mode, long-press pattern constant-stitch sewing key on the main interface to switch to pattern constant-stitch sewing editing interface "d-01 3.0", press the fourth column adjust the d01-d15 segment number, and press to adjust the current segment Stitch length.
  • Page 5 Items Range Default Description 0: OFF 1: Chinese 2: English P17-N04 Language setting 3: Vietnamese 4: Portuguese 5: Turkish 6: Spanish 0: No key tone, no error voice 1: With key tone and error voice P17-N05 Voice broadcast selection 2: Key tone only 3: Error voice only Automatic piece counting 0: OFF...
  • Page 6 Items Range Default Description Thread tension releasing 0: OFF 1: ON function selection 0 : OFF Thread wiping function / 1: Thread wiping function. Thread clamping function 0-11 2-11: Thread clamping Function and the strength of automatic selection thread clamping. Automatic thread trimming ON/OFF function selection...
  • Page 7 Items Range Default Description Thread trimming action time 10-990 (ms) Thread wiping action time 10-990 (ms) 0: Always not to find the up needle position Power on and positioning 1: Always to find the up needle position Presser foot solenoid Forced shutdown after hold time to prevent the electromagnet from 1-60 protection time (s)
  • Page 8 Items Range Default Description 0-359 Trimming engage angle Presser foot release buffer 0-800 working time (ms) Stopping strength after 10-100 trimming Trimming full output 10-990 time (ms) Periodic signal of trimming 1-10 output (*10%) Up and down needle position Up and down positioning distance angle (1 degree for every 4 15-345 distance values)
  • Page 9 Items Range Default Description position Clamp function without any P111 thrum switch The delay time before hook P112 0-990 thread with clamp function without any thrum The hook thread action time P113 0-990 with clamp function without any thrum The return back time of hook P114 0-990 thread with clamp function...
  • Page 10 Items Range Default Description number 0: Do not count 1. Increase cycle count 2. Decrease cycle count P165 Stitch counter mode selection 3. Increase count, alarm after the count is full, need to press the clear key to start recounting 4.
  • Page 11: Error Code List

    Items Range Default Description 2mm backward stitch length P180 0-2000 reference value setting 3mm forward stitch length P181 0-2000 reference value setting 3mm backward stitch length P182 0-2000 reference value setting 4mm forward stitch length P183 0-2000 reference value setting 4mm backward stitch length P184 0-2000...
  • Page 12 smoothly (turn the handwheel by hand), if it cannot be turned, please check the machine; 2. Turn off the power, check whether the motor power connector is loose, plug it in and restart it; 3. Check whether the upper needle stop position is correct, if not, please adjust the upper positioning position;...
  • Page 13 service. 1. Turn off the system power and check if the machine is overturned. 2. Check whether the machine protection switch detection setting is correct. Machine overturned 3. If it still does not work normally, please replace the control box or panel and notify the after-sales service.
  • Page 14 3. Check if there is oil on the grating code plate, if so, please clean it up, and restart the system after restoration; 4. If it still does not work normally, please replace the control box or back-tacking stepper motor and notify the after-sales service. 1.
  • Page 15 1. Pull thread air valve: 1(+24V), 4 2. Hook thread air valve: 2(+24V), 5 3. Suction air valve: 3(+24V), 6...