CS2 R30252.xx
from 75A to 200A
9

Burst Firing settings

The Burst Firing cycles is already configured in line with customer requirements that are defined in the Order
Code. However, if you wish to change the Burst Firing cycles (es. from 4 to 8) you must follow the following
procedure.
Remove
auxiliary power supply
Keep pressed
Supply the Unit
LED3 - LED4 flashing for 3 sec.
Release
Press
the desired configuration
BF 2
BF 4
BF 8
BF 16
25
to choose
Press
to save
the configuration
END