The Concept PDG 2906 powder dosing unit is used for continuous and time-controlled dosing of detergent in granulate, powder or block form. The Concept PDG 2906 powder dosing unit may only be used within the specified performance limits and under the permissible ambient conditions.
Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS) Directive 2011/65/EU Harmonised standards EN 60335-1:2020-08 EN 60335-2-41:2012-06 EN 61000-6-3:2011-09 EN 61000-6-2:2006-03 Herbert Saier GmbH 5 March 2021 Michael Saier (Managing Director) 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 7 / 44...
Indicates a hazard with a moderate level of risk which may result in death or serious injury. CAUTION! Indicates a hazard with a low level of risk which may result in minor or moderate injury or damage to property. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 8 / 44...
They should always be observed. Important information This information note indicates that material damage or financial loss may occur if the information is ignored. Information This symbol indicates a helpful tip. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 9 / 44...
Check delivery package contents against the delivery note immediately upon receipt of goods. Later complaints cannot be considered. Quantity Components Concept PDG 2906 peristaltic dosing pump with 5-core cable Tube kit Sealing plug for the tube kit Connecting plug for the tube kit...
Description Description The Concept PDG 2906 powder dosing unit is used for continuous and time-controlled dosing of detergent in powder, granulate or block form. The system Fig. 1: Powder dosing system Item Component Function Powder dosing solenoid valve Opens and closes the supply of fresh water for...
Increase value ✓ button Confirm input Continue to next menu item Button combination Function ESC button and button Pump runs for the specified filling time at maximum speed 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 15 / 44...
Page 16
Flashing rapidly Maximum dosing time exceeded (container empty or other fault) Flashing slowly Conductivity sensor ILFS not detected Only for operating modes with conductivity control For all operating modes 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 16 / 44...
If the medium has to be introduced bubble-free, the injection point is installed on the underside of the pipe (2). Important information If injection points are used, it is important to ensure that only small pressure losses occur at the injection points. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 17 / 44...
Undo the four screws in the pump housing (1). Separate the pump housing from the connection box (2). The device is ready for installation. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 18 / 44...
Press the sealing plug (1) into the opening in the tube holder. Fig. 5: Seal the tube kit 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 19 / 44...
Rotate the rotor several times to align the pump tube. Refit the rotor cover (2). Refit the pump housing cover (1). The tube kit is fitted. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 20 / 44...
• If the dosing system is connected to a 230 V mains independent of the machine, an all-pole disconnector must be provided in the power supply line! 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 21 / 44...
Piezo buzzer connection Piezo buzzer connection “Data bus” terminals Connection of data bus to power supply +5 V DC 5-core connection cable Connection of power supply and 3 control inputs 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 22 / 44...
Fig. 7: “230 V” connection and “sensors” terminal strip Terminal Designation Note A - B Neutral and live Connected at the factory C - D Powder dosing solenoid valve Controls the water supply 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 23 / 44...
1.1.10 CTLOG 2013 connection Fig. 8: CTLOG 2013 connection Terminal Designation Note Earth (ground) Bus line A (RS-485) Bus line B (RS-485) Supply voltage +15… 24 V DC 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 24 / 44...
SWB signalling device connection Supply voltage +15 … 24 V DC ILFS 02 connection Conductivity sensor Data Supply voltage +15 … 24 V DC Flow meter connection Data 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 25 / 44...
Installation Installing an additional pump (Concept 2105 dosing pump) The Concept PDG 2906 dosing pump is designed to control other dosing pumps (additional pumps). Concept PDG 2906 Concept 2105 The Concept 2105 additional pump can be operated in two modes: •...
The supply voltage for the control unit and additional pump must be in phase! Two different voltages! • Terminals 1-6: 230 V • Terminals 9-15: Safety Extra Low Voltage The two voltages must be kept separate in accordance with regulations. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 27 / 44...
Page 28
Neutral Warning device connection 230 V~ conductor N (Warning signal SWB 8009-LED, SWBH-LED) Connection SD bus to control device Concept PDG 2906 Suction lance float switch connection, floating Connection SD bus to control device Concept PDG 2906 Sensor Connection for floating normally open contact, frequency signal or flow...
The control program with the highest number is always the active one. The special program always has priority over the other programs. Winter time Set winter time in the menus: • “Timer” menu • “Date/time” menu 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 29 / 44...
Note: The underlined value can be changed. Change status Status Use the buttons to select a status. Press the button to confirm the input. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 30 / 44...
Measure rinse-aid pump volumetrically. Divide the measured value in ml/h by the displayed value in ml/h. Round the result to two decimal places and enter that value as the correction value. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 31 / 44...
Enter code number 2* Change code number 1 Change code number 2 Note: Code number 1 is the access password for the menu. Code number 2 is the main password. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 34 / 44...
Menu Configuration of Concept 2105 additional pump 1. Connect PC to PDG 2906-I (via WLAN or via USB interface using the Saier data transfer adapter). 2. Start SSC software. 3. Select PDG 2906-I. 4. Click on “Component pump”. The additional pump is registered.
Measure rinse-aid pump volumetrically. Divide the measured value in ml/h by the displayed value in ml/h. Round the result to two decimal places and enter that value as the correction value. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 36 / 44...
Fix process error Modify the work process Adjust parameters on pump If it is not possible to solve the problem with this information, please contact our customer service department directly. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 37 / 44...
Replace the tube kit regularly! The pump tube wears during operation, which reduces the flow rate. If the tube kit with the pump tube is not replaced regularly, the tube will rupture. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 38 / 44...
Use long-nose pliers or a rotor key to rotate the rotor clockwise into the “D” position. Pull the tube holder down out of the fitting. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 39 / 44...
Page 40
Slide the tube holder fully into both guides. Check that the tube holder sits flush. Rotate the rotor several times to align the pump tube. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 40 / 44...
Page 41
Dispose of the device, packaging and replaced parts in accordance with the regulations applicable in the country where the device was installed. The device must not be disposed of with household waste. 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 41 / 44...
Page 42
Concept PDG 2906 21-21016 230 V 50/60 Hz; 20 VA 1 CE marking 2 Type designation 3 Serial number 4 Operating voltage, frequency, power consumption 5 Barcode 2022/04 Operating instructions Concept PDG 2906 peristaltic dosing pump 42 / 44...
Page 43
Article number 21016 Firmware version 2.62 and later Creation date 2022/4 Modified Revision Approved by M. Saier...