Power Requirements USB Connection Antenna Connection LED Indicator Mechanical Diagram Mechanical Layout Technical Specifications New Zealand and Australia European Standards UK Conformity Assessment Mark FCC Compliance Statements Industry Canada Statement Disclaimer and Warranty PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
Controller Hardware Only controllers equipped with a USB port are capable of communicating with the cellular modem. If it is not practical to physically check each controller for a USB port, contact ICT Technical Support with a list of the controller serial numbers.
(RS-485 N+, N-, NA, NB) DIN Rail Enclosure Additional DIN Rail Enclosure(s) Controller Reader Expander Dialer’s Earth Ground Connection Input Expander Power Supply Output Expander AC Mains Wiring Earth Ground Link Connection PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
Page 6
Note that the DIN rail enclosure earth terminal is connected to the power supply V- terminal. There must be only one single earth grounding point per system. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
A Protege DIN rail module can be removed from the DIN rail mount using the following steps: Insert a flat blade screwdriver into the hole in the module tab clip. Lever the tab outwards and rotate the unit off the DIN rail mount. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
Connect the USB-A end of the cable to the USB port of the Protege controller, and the USB-C end of the cable to the USB port of the cellular modem. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
A SIM is required from a validated cellular network provider in the region where the Protege DIN Rail Cellular Modem is installed. For a list of validated network providers for each region, please contact ICT Technical Support. Only validated cellular networks are supported. Others may not work correctly and will not be supported by ICT.
Registered on the cellular network (i.e. communicating with a cell tower) Blinking (1s / 1s) This does not indicate that an internet connection has been established or that data can be sent. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
The mechanical diagram below outlines the essential details needed to help ensure the correct installation of the DIN Rail Cellular Modem. SMA Antenna Connection Micro-SIM Card Slot 12VDC IN USB-C Port 12VDC IN LED Indicator PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
Mechanical Layout The mechanical layout shown below outlines the essential details needed to help ensure correct installation and mounting. All measurements are shown in millimeters. 38.90 Front 38.90 19.45 19.45 Back 27.68 PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
70g (2.5oz) Gross Weight 200g (7.1oz) Operating Conditions Operating Temperature -10° to 55°C (14° to 131°F) Storage Temperature -10˚ to 85˚C (14˚ to 185˚F) Humidity 0%-93% non-condensing, indoor use only (relative humidity) PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
Page 14
Integrated Control Technology continually strives to increase the performance of its products. As a result these specifications may change without notice. We recommend consulting our website (www.ict.co) for the latest documentation and product information.
New Zealand and Australia Intentional Transmitter Product Statement The R-NZ compliance label indicates that the supplier of the device asserts that it complies with all applicable standards. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
Tests EMC (operational) according to EN 55032:2015 Radiated disturbance EN 55032:2015 Power frequency magnetic field immunity tests (EN 61000-4-8) Power Supply Type A (EN 50130-4 ed. 2) Mains supply voltage variations (EN 50130-4 ed. 2) PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
Page 17
Warning: Enclosures supplied by 3rd parties may not be EN50131-compliant, and should not be claimed as such. To comply with EN 50131-1 only one battery can be connected and monitored per system. If more capacity is required a single larger battery must be used. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
UK Conformity Assessment Mark General Product Statement The UKCA Compliance Label indicates that the supplier of the device asserts that it complies with all applicable standards. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. FCC Part 22/24, FCC ID RI7ME910G1WW PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
Cet appareil numérique de classe B est conforme à la norme canadienne ICES-003. CAN ICES-3 (B) / NMB-3 (B) (ISED only) / (ISDE seulement) Cellular Modem REGISTRATION NUMBER IC: RI7ME910G1WW Cellular Modem NUMÉRO D'ENREGISTREMENT IC: RI7ME910G1WW PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
Integrated Control Technology Ltd nor its employees shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information. In accordance with the ICT policy of enhanced development, design and specifications are subject to change without notice.
Page 22
In accordance with the ICT policy of enhanced development, design and specifications are subject to change without notice.