ICT PRT-4G-USB Installation Manual

Protege din rail cellular modem
Hide thumbs Also See for PRT-4G-USB:

Advertisement

Quick Links

PRT-4G-USB
Protege DIN Rail Cellular Modem
Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRT-4G-USB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ICT PRT-4G-USB

  • Page 1 PRT-4G-USB Protege DIN Rail Cellular Modem Installation Manual...
  • Page 2 Protege® Logo are registered trademarks of Integrated Control Technology Limited. All other brand or product names are trademarks or registered trademarks of their respective holders. Copyright © Integrated Control Technology Limited 2003-2022. All rights reserved. Last Published: 30-Mar-22 5:17 PM PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 3: Table Of Contents

    Power Requirements USB Connection Antenna Connection LED Indicator Mechanical Diagram Mechanical Layout Technical Specifications New Zealand and Australia European Standards UK Conformity Assessment Mark FCC Compliance Statements Industry Canada Statement Disclaimer and Warranty PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 4: Introduction

    Controller Hardware Only controllers equipped with a USB port are capable of communicating with the cellular modem. If it is not practical to physically check each controller for a USB port, contact ICT Technical Support with a list of the controller serial numbers.
  • Page 5: Grounding Requirements

    (RS-485 N+, N-, NA, NB) DIN Rail Enclosure Additional DIN Rail Enclosure(s) Controller Reader Expander Dialer’s Earth Ground Connection Input Expander Power Supply Output Expander AC Mains Wiring Earth Ground Link Connection PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 6 Note that the DIN rail enclosure earth terminal is connected to the power supply V- terminal. There must be only one single earth grounding point per system. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 7: Mounting

    A Protege DIN rail module can be removed from the DIN rail mount using the following steps: Insert a flat blade screwdriver into the hole in the module tab clip. Lever the tab outwards and rotate the unit off the DIN rail mount. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 8: Connections

    Connect the USB-A end of the cable to the USB port of the Protege controller, and the USB-C end of the cable to the USB port of the cellular modem. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 9: Antenna Connection

    A SIM is required from a validated cellular network provider in the region where the Protege DIN Rail Cellular Modem is installed. For a list of validated network providers for each region, please contact ICT Technical Support. Only validated cellular networks are supported. Others may not work correctly and will not be supported by ICT.
  • Page 10: Led Indicator

    Registered on the cellular network (i.e. communicating with a cell tower) Blinking (1s / 1s) This does not indicate that an internet connection has been established or that data can be sent. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 11: Mechanical Diagram

    The mechanical diagram below outlines the essential details needed to help ensure the correct installation of the DIN Rail Cellular Modem. SMA Antenna Connection Micro-SIM Card Slot 12VDC IN USB-C Port 12VDC IN LED Indicator PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 12: Mechanical Layout

    Mechanical Layout The mechanical layout shown below outlines the essential details needed to help ensure correct installation and mounting. All measurements are shown in millimeters. 38.90 Front 38.90 19.45 19.45 Back 27.68 PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 13: Technical Specifications

    70g (2.5oz) Gross Weight 200g (7.1oz) Operating Conditions Operating Temperature -10° to 55°C (14° to 131°F) Storage Temperature -10˚ to 85˚C (14˚ to 185˚F) Humidity 0%-93% non-condensing, indoor use only (relative humidity) PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 14 Integrated Control Technology continually strives to increase the performance of its products. As a result these specifications may change without notice. We recommend consulting our website (www.ict.co) for the latest documentation and product information.
  • Page 15: New Zealand And Australia

    New Zealand and Australia Intentional Transmitter Product Statement The R-NZ compliance label indicates that the supplier of the device asserts that it complies with all applicable standards. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 16: European Standards

    Tests EMC (operational) according to EN 55032:2015 Radiated disturbance EN 55032:2015 Power frequency magnetic field immunity tests (EN 61000-4-8) Power Supply Type A (EN 50130-4 ed. 2) Mains supply voltage variations (EN 50130-4 ed. 2) PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 17 Warning: Enclosures supplied by 3rd parties may not be EN50131-compliant, and should not be claimed as such. To comply with EN 50131-1 only one battery can be connected and monitored per system. If more capacity is required a single larger battery must be used. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 18: Uk Conformity Assessment Mark

    UK Conformity Assessment Mark General Product Statement The UKCA Compliance Label indicates that the supplier of the device asserts that it complies with all applicable standards. PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 19: Fcc Compliance Statements

    NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. FCC Part 22/24, FCC ID RI7ME910G1WW PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 20: Industry Canada Statement

    Cet appareil numérique de classe B est conforme à la norme canadienne ICES-003. CAN ICES-3 (B) / NMB-3 (B) (ISED only) / (ISDE seulement) Cellular Modem REGISTRATION NUMBER IC: RI7ME910G1WW Cellular Modem NUMÉRO D'ENREGISTREMENT IC: RI7ME910G1WW PRT-4G-USB | Protege DIN Rail Cellular Modem | Installation Manual...
  • Page 21: Disclaimer And Warranty

    Integrated Control Technology Ltd nor its employees shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information. In accordance with the ICT policy of enhanced development, design and specifications are subject to change without notice.
  • Page 22 In accordance with the ICT policy of enhanced development, design and specifications are subject to change without notice.

Table of Contents