MAINTENANCE
The maintenance for APS System is primarily based on clean-up. The more
often the unit is cleaned, the better. Daily cleaning of the system is strongly
recommended.
To clean the unit:
1- Raise the base plate to upright position and lock in place.
2- Remove the suction tube from the adhesive pail. (Keep a damp rag handy
for any drips)
3- Close the small knob on the back of the gun by turning clockwise. This
will prevent the adhesive from atomizing during the cleaning process.
4- Open the large knob on the back of the gun 3-4 turns counter clockwise.
5- Aim the nozzle into the pail of adhesive and pull the trigger. A straight
stream of adhesive should be shooting back into the pail, bleeding the
lines, while not wasting any product.
6- Place the suction tube into a small bucket of water or water soluble
cleaner. Direct the gun into a waste container and pull the trigger until the
water/ cleaner is flowing through the hoses and out the nozzle of the spray
gun.
7- Wipe the Air cap down with a suitable cleaner or solvent to remove any
dried adhesive.
This entire process should be no more than 10 minutes.
APS Adhesive System
The APS will greatly reduce your cost for pallet adhesives compared to aerosol
cans while also providing a cleaner, safer work environment. The following pages
will assist in assembly, operation, and maintenance of the unit.
vvvvvvvvvvvvvvvvvv
36-41 36
Street
th
Long Island City, NY 11106
Tel. 718-392-6272
5439 San Fernando Road W.
Los Angeles, CA 90039
Tel. 818-543-5071

Advertisement

loading
Need help?

Need help?

Do you have a question about the 2034 and is the answer not in the manual?

Questions and answers

Summary of Contents for AlbaChem 2034

  • Page 1 APS Adhesive System MAINTENANCE The maintenance for APS System is primarily based on clean-up. The more often the unit is cleaned, the better. Daily cleaning of the system is strongly recommended. To clean the unit: 1- Raise the base plate to upright position and lock in place. 2- Remove the suction tube from the adhesive pail.
  • Page 2 UNPACKING 5- Feed the braided suction tube through the large hole in the The following items should be included in the box, please make sure all pieces are pump plate so that it will align with the cap of the glue bucket. present.