Dehumidifi er White Wire Blue Wire Green Wire Install the D30 control panel in a central area of the (Optional. See warning below) structure where it will sense the relative humidity of the structure accurately. Do not install the control panel where...
2.2 Wiring ventilation using the ventilation timer function of the D30 and the terminal labeled “DMP” on the D30 (See WARNING! Section 3.8). Leave the “DMP” terminal unused if a DO NOT ALLOW THE +24V motorized damper is not used, and cap off the White TERMINAL ON THE ENVIROWISE DEHUMIDIFIER TO wire from the Envirowise dehumidifi er.
24VAC The incorrect wire will give a 20 to 28 volt reading. TRANSFORMER BLACK 2. Another Yellow wire must be added to the thermostat Yellow terminal and run to the “ON-D” sensor terminal on the D30. GREEN COMP YELLOW UNIT...
CONNECTIONS OR TRANSFORMER DAMAGE MAY hook-up. RESULT. 1. Install front cover of the D30; connect the top first, then the bottom. 7. Verify any additional optional control operations such as fan 2. Plug in the Envirowise dehumidifier. The D30 should interlock or A/C lockout.
3.5 Adjusting the Relative Humidity “SETPOINT” 3.2 Setting The D30 senses the ambient relative humidity (%RH) of the During the set-up process, if you make a mistake, simply space in which it is located, it comes factory preset to hold continue.
If the setpoint is higher than the ambient relative humidity, the or air recirculation. space does not need to be dehumidified, so the dehumidifier “AUTO” – Indicates the fan will run when the D30 calls for will not run. dehumidification or ventilation. If the control has not called for...
The ventilation indicator “O” will be displayed whenever the unit The D30 will operate fresh air ventilation according to your is ventilating. The fan operation indicator “O” will also be lit. ventilation program. The control needs to be programmed to There are three damper operation modes: turn the ventilation function ON and OFF at the desired intervals.
Page 9
This schedule of 15 minutes open, 15 minutes closed will continue until the start time of the night schedule. Morning schedule is available anytime from 12:00AM until 11:59AM. Night schedule is available anytime from 12:00PM until 11:59PM. D30 Dehumidifier & Ventilation System Controller Installation, Operation & Service Manual...
4.0 D30R — Remote sensor option. This section is applicable only to customers who have purchased a remote sensor package. The standard D30 controller does not offer remote functionality. PN# E4037897 5.1 Remote Sensor Usage • Do not run wires longer than 100 ft.
Page 11
D30 Dehumidifier & Ventilation System Controller Installation, Operation & Service Manual...
Page 12
Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sustainable and effi cient environments. Our people and our family of brands—including Club Car®, Ingersoll Rand®, Thermo King® and Trane®—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and effi...