Summary of Contents for AKKU SYS a-TroniX Parallel Interface Card 6-10 kVA
Page 1
PARALLEL INTERFACE CARD User Manual 6 bis 10kVA Model Article number a-TroniX Parallel Interface Card 6-10 kVA 9885111 09/2021 Page 1...
Page 2
All rights reserved. AKKU SYS Akkumulator- und Batterietechnik Nord GmbH cannot be held responsible for any inaccuracies or inappropriate information in this instruction manual. The information in this document is subject to change without notice, but there is no obligation to update it on an ongoing basis.
Page 3
User Manual a-TroniX Parallel Interface Card 6–10 kVA 1. Parallel Interface Card (Kit) It is composed by parallel card, parallel connection board, parallel cable 1 (flat), parallel cable 2 and DB15 parallel cable. Parallel Card Parallel connection board Parallel cable 1 (connect between the parallel card and the control logic board) 09/2021 Page 3...
Page 4
User Manual a-TroniX Parallel Interface Card 6–10 kVA Parallel cable 2 (connect between the parallel card and the parallel connection board) DB15 parallel cable (connecting between UPS 1 & 2) Page 4 09/2021...
User Manual a-TroniX Parallel Interface Card 6–10 kVA 2. Installation 1. Make sure the UPS is completely OFF. Remove the outer cover and also the blind plate on the rear and the screws of the parallel connection board as illustrated below. 2.
Page 6
User Manual a-TroniX Parallel Interface Card 6–10 kVA 3. Connect parallel cable 1 between the parallel card and the control logic board, and connect parallel cable 2 between the parallel card and the parallel connection board as illustrated below. 4. Connect the DB15 parallel cables among UPS1, UPS 2, UPS3 and UPS4 in ring type as illustrated.
Page 7
User Manual a-TroniX Parallel Interface Card 6–10 kVA 3. Parallel Function Test 1. The minimum UPS systems in parallel is 2 and the maximum UPS systems in parallel is 4. Each UPS has been required to have its own parallel kit. 2.
Page 8
User Manual a-TroniX Parallel Interface Card 6–10 kVA 5. Recycling & ENVIRONMENT Do not discard waste electrical or electronic equipment (WEEE) in the trash. ■ Refer to your local codes for disposal requirements. For more information, contact us on the hotline +49 4101/376760, ■...