Instruction Load Arrestor - protecta Load : max 300 kg, Length : max 12 m 1 - Important information : Capital Safety Group load arrestors are used where loads need to be secured. The load arrestor will prevent the load from falling in case of failure of the main holding system.
Page 2
No additional sling or device shall be between the load and the fall arrestor cable. It shall be ensured that the working stroke of the load shall not exceed the maximum length of the load arrestor cable. In the case of fall, the load will be stopped. The damaged or broken fall indicator will indicate that the fall has occurred.
Page 3
Pull all the cable out and check carefully that no excessive corrosion appears (B) no wire of the cable is broken (C) the ferrules are not damaged (D) B + C Check that the fall indicator is intact. (E) Important The load arrestor may be damaged if you let the cable wind back up into the casing without holding the wire.