CDSVAN
PSU04 - Power Supply Unit
Operating instructions
REV 1.61

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CDSVAN PSU04 and is the answer not in the manual?

Questions and answers

Summary of Contents for Brähler Systems CDSVAN PSU04

  • Page 1 CDSVAN PSU04 - Power Supply Unit Operating instructions REV 1.61...
  • Page 2 Printed in Germany Should you have any questions about this manual, please contact: Brähler ICS Konferenztechnik International Congress Service AG P.O. Box 32 64 53627 Königswinter, Germany T +49 2244 9300 F +49 930 450 sales@braehler.com You will find further information about our products on the internet at: www.braehler.com ©...
  • Page 3: Safety Information

    CDSVAN PSU04 Safety information ! CAUTION ! DANGER OF ELECTRIC SHOCK DO NOT OPEN DEVICES Do not open housing with mains cable connected. Maintenance operations may only be done by qualified personnel. Our equipment and installations have been built and tested according to the latest state of the art. In general conditions, they do not require any special maintenance.
  • Page 4 PSU04 CDSVAN Copyright © by Brähler ICS...
  • Page 5: Table Of Contents

    CDSVAN PSU04 Table of contents Safety information ..................... 3 About this manual ..................... 6 Symbols ..........................6 General ..........................6 Important remarks ..................... 7 The PSU04 Power Supply Unit ..................8 Content of basic delivery ....................... 8 Optional accessories (not in delivery) ..................8 CAT5 Cable usage ........................
  • Page 6: About This Manual

    PSU04 CDSVAN About this manual Symbols The meanings of the symbols and fonts used in this manual are as follows: Indicates an important note or instruction, if not followed, the operation of the unit, the security of your data, or even of your health are put at risk. Gives supplementary informations, remarks, and tips.
  • Page 7: Important Remarks

    CDSVAN PSU04 Important remarks For customers in the EU and in the USA The equipment is complying to the standards of the CE regulations. These standards are specified to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 8: The Psu04 Power Supply Unit

    PSU04 CDSVAN The PSU04 Power Supply Unit Thank you for choosing this product of BRÄHLER ICS. The PSU04 is a power supply for conference units to use within the CDSVAN system for power supply and data refresh. It supports up to 32 channels. The unit will be directly connected to the CDSVAN-PC and can control delegate units or interpreter consoles at 4 outputs.
  • Page 9: Cdsvan System Components

    CDSVAN PSU04 CDSVAN System Components CDSVAN discussion software (Art. no. S5.0050) Microphone management software CDSVAN interpretation software (Art. no. S5.0060) Interpretation system software DSP6/EDAT (Art. no. 07.0275.C) Digital Signal Processor Card with I/O adapter “EDAT” DV9 (Art. no. 05.4030) Digital Delegates´ Unit with language selector for up to 32channels EDV9 (Art.
  • Page 10: Operating Controls

    PSU04 CDSVAN Operating controls Front view The front side of the PSU04 is equipped with: 1 power switch with green “power-on” light indication 4 green LEDs for 48VDC output indication 4 red LEDs for short-circuit indication The failure can not be removed by switching on and off the system. This could damage the output line.
  • Page 11: Rear View

    CDSVAN PSU04 Rear view The rearside of the PSU04 is equipped with: Mains power connector Screw for earthing Air outlet for ventilation RJ45 connectors 2 PC (IN) 2 LINK (OUT) 2 UNITS A 2 UNITS B 2 DIP-switches (OFF/100R) 2 DIP-switches (SHORT/LONG) Copyright ©...
  • Page 12: Set-Up

    PSU04 CDSVAN Set-up Before power-on the power supply unit PSU04, please connect the necessary cables. Then proceed with the DIP-switch settings regarding to your specific system. After correct DIP-switch settings and termination (see chapter “DIP-switch settings”) you can power-on the PSU04. The green LED in the mains switch and the green LED´s from the connected lines light up in case that the installation is correct.
  • Page 13: Earth Connection

    CDSVAN PSU04 Earth connection Terminal connection for additional earthing: Left beside the mains power inlet connector. To avoid any power stroke, the metal housing of the PSU04 must be connected to earth via mains cable. For low impedance grounding, the metal housing of the PSU04 can be additionally connected via extra ground at this earth connection on the backside of the unit.
  • Page 14: Units A

    PSU04 CDSVAN UNITS A Two connectors for the connection of next units with CAT5 cable for the transfer of up to 32 language channels with 48VDC/1.3A nominal. (UNITS 1 / UNITS 2) UNITS B Two connectors for the connection of next units with CAT5 cable for the transfer of up to 32 language channels with 48VDC/1.3A nominal.
  • Page 15: Dip-Switch Settings

    CDSVAN PSU04 DIP-switch settings Termination of LINK connectors Electrical digital data lines have to be terminated to avoid data transmission errors. The 2.generation of CDSVAN delegate units/ interpreter consoles (PV9, DV9, EDV9, DOLV) are equipped with automatical termination. For use with previous versions of delegate units/ interpreter consoles, please contact Brähler ICS for information.
  • Page 16: Troubleshooting Table

    PSU04 CDSVAN Troubleshooting table Error description Error cause Error solution After powering up the PSU04, the No mains power. Connect the mains power cable to unit doesn´t work. (Green indication the power outlet. LED in mains switch is off.) Unit doesn´t work. (All LED´s on the The internal power supply is Contact Brähler ICS for front panel are off.)
  • Page 17: Appendix

    CDSVAN PSU04 Appendix Technical data Features  Green lighted mains switch for power ON indication  4 green LEDs for 48VDC output indication  4 red LEDs for short-circuit indication at the corresponding 4 outputs  2 DIP-switches for adapting of different cable lengths ...
  • Page 18: Block Diagram

    PSU04 CDSVAN Block diagram General overview of CDSVAN components DV9 Digital Delegate Unit Remote Access DV9 Digital Delegate Unit DOLV Digital Interpreter Console CDSVAN Computer EWV32 Channel selector PSU04 Power Supply Unit DSP6 PCI-Card MSI8V Compact Transmitter IRad (INFRACOM ® ) High Power Radiator IRX (INFRACOM ®...
  • Page 19: Service Form

    SERVICE FORM Material return shipments for repair-, service-, or guaranty purposes please send to: BRÄHLER ICS Konferenztechnik AG, Auf der Alten Burg 6, D-53639 Königswinter, Germany Phone +49 (0)2244 930-0, Fax +49 (0)2244 930-450 Dear customer, Please ask our sales staff for the RMA number (Return of Material Authorization). Without RMA number a treatment is not possible! Please always include this service form, fully completed, with any complaint or repair wish you may have.
  • Page 20 PSU04 CDSVAN Copyright © by Brähler ICS...
  • Page 21: Contact Information

    CDSVAN PSU04 Contact information Head Office BRÄHLER ICS Konferenztechnik International Congress Service AG P.O.Box 32 64 53627 Königswinter, Germany Auf der Alten Burg 6 D-53639 Königswinter, Germany T +49 (0) 2244 930-0 F +49 (0) 2244 930-450 www.braehler.com Event Technology T +49 (0) 2244 930-200 F +49 (0) 2244 930-430 rental@braehler.com...
  • Page 22 Phone +49 (0)2244 930-0 www.braehler.com 05.4202...

Table of Contents