Download Print this page

Advertisement

Quick Links

Net2 quickstart installation guide
About
This document is a brief guide to installing and commissioning a Net2 system. If you are new to Net2 please
read through the Net2 installation reference manual before attempting installation!
Wiring
CARDLOCK reader
Membrane or
stainless steel
keypad
1
2
ABC
DEF
3
4
GHI
JKL
6
5
MNO
PQR
8
7
ST
UV
9
0
WX
YZ
From
previous
ACU
Note about wiring keypads: A 220Ohm resistor must be wired in series with the green cable core. The
resistor is supplied in the keypad fitting kit.
What data cable should be used?
The hardware has been improved to accommodate using Category 5 (CAT5) cable for networking the Net2
controllers. The network labelling has been changed to reflect this. It is still OK to use Beldon 8723 cable.
Table showing data
cable connections
Things to look out for when wiring:
Are the end of line termination resistors in place?
Are the reader and data cable screens connected throughout?
(Reader and keypad screens should be connected to the Blk/Wht terminal)
Ins-150
IMPORTANT: the red wire on
PROXIMITY reader
Paxton Slimline, Vandal proof,
Back box and Panel mount
PROXIMITY readers must be
connected to the +12V terminal
Keypad 2
Reader 2
Red
Brown
Net2
Orange
Green
Yellow
1 Door
Blue
Access Control Unit
Mauve
Black/White
Brown
Yellow
PAXTON
Orange
Screen or spare cores
ACCESS
from network cable
Simple & Powerful
1
White/Green
Green
2
3
White/Orange
4
Orange
Refer to network
wiring instructions
NETWORK CABLE
Cable core
White/Green
Green
White/Orange
Orange
+12v
0v
N.C.
N.O.
Com
N.C.
N.O.
Com
Alarm Output
0v
Contact
0v
Exit
0v
Tamper
PSU
ACU
RS485/232
1
1
2
2
3
3
4
4
Power
12V d.c
supply
power
Unswitched
supply
spur
Fail Closed
electric release
12V d.c.
alarm sounder
Normally closed
door contact
Exit Button
Tamper Switch
To next ACU
Old network labelling
OUT-B
OUT-A
IN-A
IN-B
Date code: 161002