9.1.2 Boiler service menu

ACCESS TO THE SERVICE MENU AND CHANGING PARAMETERS CAN ONLY BE CARRIED OUT BY QUALIFIED
PERSONNEL.
To continue, you must enter the password "1234". Set the cell value with the SW6 and SW7 buttons while you can change positions with the SW1 and SW2 buttons.
Confirm with the
button.

Menu for modifying the [TSP] parameters

You can scroll the list by pressing the SW1 and SW2 buttons while the value is displayed with the
with the
button or cancel with the
Index Description
b01
Boiler type selection
b02
Boiler type
b03
Gas type
b04
Water system pressure protection selection
b05
Summer/Winter function
b06
Variable input contact function selection
b07
LC32 relay board operation selection
Hours without DHW
b08
withdrawal
b09
Fault 20 status selection
b10
Not implemented
b11
Flow meter timing
b12
Comfort mode
b13
Not implemented
b14
DHW factor
b15
Flow meter type selection
b16
Not implemented
b17
Not implemented
DHW mode activation flow
b18
rate
DHW deactivation flow
b19
rate
b20
Flue material selection
b21
Not implemented
b22
Not implemented
Maximum temperature standard flue switch
b23
off
b24
Maximum temperature PVC flue switch off
b25
Maximum temperature CPVC flue switch off 60-110°C
b26
Not implemented
button.
Modulation
3 = COMBINED MONOTHERMAL (DO NOT MODIFY)
1 = 24_C
2 = 28_C
3 = 34_C
4 = 45_C
5 = 24_C (high range)
6 = 28_C (high range)
7 = 34_C (high range)
0 = Methane
1 = LPG
2 = Propane-air
0 = Pressure switch
1 = Pressure transducer
0 = WINTER - SUMMER - OFF
1 = WINTER - OFF
0 = Flow meter exclusion
1 = System thermostat
2 = Second Room thermostat
3 = Warning/Notification
4 = Thermostat safety device
0 = External gas valve
1 = Alarm
2 = System loading solenoid valve
3 = Solar 3-way valve
4 = Second heating pump
5 = Alarm2
6 = Burner on
7 = Antifreeze active
0-24 hours (time for temporary deactivation
of comfort without withdrawal)
0 = Disabled
1 = Enabled (Only for versions with pressure transducer)
--
0 = Disabled
1-10 = seconds
0 = Activation with withdrawal
1 = Always active
--
0 - 1
1 = Flow. (450 sys/l)
2 = Flow. (700 sys/l)
3 = Flow (190 sys/l)
--
--
0-100L/min/10
0-100L/min/10
0 = Standard
1 = PVC
2 = CPVC
--
--
60-110°C
60-110°C
--
Cod. 3542B250 - Rev. 00 - 02/2022
button. To modify, press the SW6 and SW7 buttons, confirm
Default
3
6
0
1
0 = Enabled
2
0
24
0
--
0
0
--
0
3
--
--
25
20
0
--
--
105
93
98
--
51