MADRIX ORION Technical Manual & Quick Start Manual page 8

Hide thumbs Also See for ORION:
Table of Contents

Advertisement

Available languages

Available languages

1) Connecting Your Input Equipment
See chapter 'Connection Diagram Examples' on p. 8 for more information.
Step 1) Completely switch off your supply of power before connecting your
input equipment to the device!
Step 2) Connect your input equipment to the provided 6-pin screw terminals:
» You may connect only to Port 1, only to Port 2, or to Port 1 and Port 2.
» For each pin, connect GND (Ground) and V+ to the same port as the pin.
» Pay attention where to connect Ground, Signal, and V+;
as indicated on the device as well as required by the diagram.
» Insert each individual wire consecutively and tighten the corresponding
screw with a suitable screw driver.
Step 3) Plug the 6-pin screw terminals into the device. The screws must face
upwards.
Step 4) Continue with '2) Connecting To Power And Data' below.
2) Connecting To Power And Data
See chapter 'Connection Diagram Examples' on p. 8 for more information.
Step 1) Be careful when handling the device and electrical power! Completely
switch off your supply of power before connecting to the device!
Step 2) Connect your power cables to the provided 2-pin screw terminal:
» Pay attention where to connect + and –; as indicated on the device.
» Insert each individual wire consecutively and tighten the corresponding
screw with a suitable screw driver.
Plug the 2-pin screw terminal into the device. The screws must face
upwards. Alternatively, you can supply 5 V power over USB.
Step 3) Connect to USB or to Ethernet network to send data as required.
Step 4) Do not switch on your supply of power until all required power cables
are connected to MADRIX
Step 5) Continue by configuring your device as described in chapter
'3) Device Configuration' on p. 13.
7
EN
®
ORION.

Advertisement

Table of Contents
loading