IP configuration. Features • Features SonicIP® announcing the IP address on power up over the audio outputs. The encoder/decoder Solidyne ADA102 is a stand • Control and configuration using a standard alone streaming generator, designed to work as Studio web browser.
XLR-3 for the inputs and male for the outputs. Take specially care with AES3 (1) the phase. AES3 (2) Use one pair shielded audio cables of good AES3 standard connection quality, preferably with double shielding. The SOLIDYNE ADA102 CODER/DECODER Page 5...
Solidyne processors have MPX differential outputs, that is to say, with the • Open an Internet browser, enter the ADA102 IP address ground isolated from the cabinet, to avoid ground followed by /status (i.e.: 102.168.0.110/status).
LED has indicated the error as follows: ERROR Green LED blinks Corrupt application or IP address conflict five times The Network hardware could not be initialized three times or a Corrupt MAC address SOLIDYNE ADA102 CODER/DECODER Page 7...
AGC compression be 10 dB or higher. • If you have a modulation meter available (Solidyne VA16, Belar, Innovonics, etc.) we • Adjust carefully the ADA102 input gain to recommends to use the measurements of obtain a 0 VU deviation with the peaks.
- 6 dBfs - 3 dB - 9 dBfs 0 dBfs * Value for Solidyne digital processors The knob level at the front panel only takes effect over analog inputs, and the VU meters do not operate with digital signal.
Write this IP address down and 20. NOTE: If at any time you get an error 400, send to the remote location technician. This just refresh the screen. is the static IP you should’ve been given by SOLIDYNE ADA102 CODER/DECODER Page 11...
IP address for your unit, the encoder unit needs to do the same and send you that info. You will now be receiving (PULLING) the audio from that specific IP ADDRESS. 14. 14. Click APPLY SOLIDYNE ADA102 CODER/DECODER Page 12...
IP Address. "255.255.255.0" for a C class network Step 4 Default: "255.255.255.0". Look for the Solidyne ADA102 MAC address printed on Gateway IP Address: Enter the IP address of the a label placed on the rear panel (12 hex digits, Gateway e.g.:...
Enter up to 15 Characters. Web server port: Defines the port where the webserver of the Solidyne device can be reached. If set to By default, relay Nº1 is ON while the connection is "0" the default HTTP port (80) is used.
If the incoming streaming drops, ADA102 can play (1Kbit = 1000 bits) audio files from a pendrive plugged on USB port. When the audio stream is reestablished the system will fold back to incoming streaming. SOLIDYNE ADA102 CODER/DECODER Page 15...
URL enter the IP address or URL of the CODER Port” value assigned to the decoder in the Transmitter in Studios. “Destination Port” must be the same Plant. assigned in the CODER. Hit “Apply” to confirm. SOLIDYNE ADA102 CODER/DECODER Page 16...
This configuration is common when you have a static IP to the “multicast” group and requires a half-duplex link. In both Studio ans in Plant, ADA102 is set as “Multicast” (Configuration → Basic settings → Stream Method). SOLIDYNE ADA102 CODER/DECODER Page 17...
The encoder uses Variable Bitrate Encoding (VBR) to realize optimal compression of the audio Variable Bit Rate (VBR) data. The setting of a fixed bitrate is replaced with setting a quality level that preserves audio Encoding quality in critical sections and enhances compression otherwise. SOLIDYNE ADA102 CODER/DECODER Page 19...
75 dB minimum below 100% modulation. 38 kHz Suppression 57, 76 and 95 kHz 75 dB minimum below 100% modulation. Suppression Pilot Level Adjusted 7-12 % from rear panel preset control Pilot Stability +/- 0.05 Hz, 0 to 50 °C. SOLIDYNE ADA102 CODER/DECODER Page 20...