INSTALLATION MANUAL
VARIABLE SPEED SINGLE PIECE
MODULAR AIR HANDLERS
MODELS: F2FV060 / F3FV060(T)
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SPECIFIC SAFETY RULES AND PRECAUTIONS . . . . . . . . . . . . . . . 2
SAFETY REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
HORIZONTAL DRAIN PAN CONVERSION . . . . . . . . . . . . . . . . . . . . 3
DUCT CONNECTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
AIR FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SUSPENSION KITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Plenum Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dimensions & Duct Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Typical Horizontal Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
TXV Bulb Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Bulb Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Orifice Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installed Orifice or TXV Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
CFM / Tap Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Physical and Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Conversion Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical Data - 1 Ø - 208/230-1-60 . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical Data - 3 Ø - 208/230-3-60 . . . . . . . . . . . . . . . . . . . . . . . . . . 9

SAFETY

This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury. It is also used to
alert against unsafe practices and hazards involving only property dam-
age.

TABLE OF CONTENTS

COIL METERING DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
REFRIGERANT LINE CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . .6
ELECTRIC HEATERS & OPERATING CONTROLS . . . . . . . . . . . . . .6
LOW VOLTAGE CONTROL CONNECTION . . . . . . . . . . . . . . . . . . . .7
LINE POWER CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
BLOWER SPEED SELECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
DRAIN CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
COIL CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
LUBRICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
CONDENSATE DRAINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
LIST OF FIGURES
Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Line Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
CFM Selection Board Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Cooling Models with Electric Heat Wiring . . . . . . . . . . . . . . . . . . . . . .10
Two-Stage Cooling Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Heat Pump Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
LIST OF TABLES
Electrical Data - Cooling Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Copper Wire 208/230-1-60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Copper Wire 208/230-3-60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Copper Wire 208/230-1-60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer or service agency.
This product must be installed in strict compliance with the installa-
tion instructions and any applicable local, state, and national codes
including, but not limited to building, electrical, and mechanical
codes.
ISO 9001
Certified Quality
Management System
035-14519-002 Rev. B (1204)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F2FV060 and is the answer not in the manual?

Questions and answers

Summary of Contents for Unitary products group F2FV060

  • Page 1: Table Of Contents

    INSTALLATION MANUAL VARIABLE SPEED SINGLE PIECE MODULAR AIR HANDLERS ISO 9001 MODELS: F2FV060 / F3FV060(T) Certified Quality Management System TABLE OF CONTENTS SAFETY ..........1 COIL METERING DEVICES .
  • Page 2: Specific Safety Rules And Precautions

    Use hanging brackets to wall mount unit as shown below. Normal operating sound levels may be objectionable if the air han- dler is placed directly over some rooms such as bedrooms, study, etc. Unitary Products Group...
  • Page 3: Horizontal Drain Pan Conversion

    Horizontal drain cutout in the center access panel should be unit. Reinstall the coil support bracket on the right side of the coil. removed by using a utility knife (if not previously cut out). Unitary Products Group...
  • Page 4: Filter Access & Drain Pan Conversion / Coil Baffle

    FIGURE 4: Dimensions & Duct Sizes TABLE 1: Dimensions Dimensions Wiring K.O.’s* Refrigerant MODEL Connections F2FV / Line Size F3FV(T) Height Width Depth Power Control Liquid Vapor 7/8 (1/2) 50-3/4 17-3/8 20-7/8 22-1/2 1-3/8 (1), 7/8 (1/2) 1-23/32 (1-1/4) Unitary Products Group...
  • Page 5: Duct Connectors

    The temperature sensing bulb will need to be attached to porting the units from the bottom, at the locations shown in Figure 5. the coil suction header line after the line set is brazed to the coil. Unitary Products Group...
  • Page 6: Bulb Location

    If the orifice sizes match, nothing further is required and the refrigerant blower to run continuously. (See Figure 9). lines may be connected per the outdoor unit instruction. However, if another orifice should be used, change the orifice in the coil with the fol- lowing procedure: Unitary Products Group...
  • Page 7: Low Voltage Control Connection

    GND. LUG GND. SUPPLY SINGLE SOURCE (2.5 - 10 KW) GND. GND. LUG POWER SUPPLY 1 POWER POWER SUPPLY 2 SUPPLY POWER WIRING (208/230-1-60) POWER SUPPLY 3 NOTE: USE ONLY COPPER CONDUCTORS FIGURE 11: Line Power Connections Unitary Products Group...
  • Page 8: Cfm / Tap Selection

    1.0” w.c. external static pressure is not recommended. CFM SELECTION BOARD TAP SELECTION COOL HEAT DELAY REMOVE FOR HEAT PUMP HUMIDISTAT FIGURE 12: CFM Selection Board Detail FIGURE 13: Control Box Unitary Products Group...
  • Page 9: Physical And Electrical Data

    TABLE 8: Electrical Data - Cooling Only Minimum Circuit ALL VOLTAGES Ampacity MODEL 75°C Wire Size - AWG Max. O.C.P. Amps/Type 208V 240V F2FV060H06 F3FV060H06T 1. OCP = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse. Unitary Products Group...
  • Page 10: Cooling Models With Electric Heat Wiring

    CONTROL CONNECTION BOARD (”HUMIDISTAT” JUMPER ON CFM SELECTION BOARD MUST BE REMOVED THERMOSTAT OUTDOOR UNIT FIELD INSTALLED JUMPER CONTROL BOARD NOTE: THERMOSTAT TERMINAL “W” NOT USED FOR COOLING ONLY. FIGURE 14: Cooling Models with Electric Heat Wiring Unitary Products Group...
  • Page 11: Two-Stage Cooling Wiring

    CHECK THE LOW VOLTAGE TERMINAL BLOCK ON THE INDOOR UNIT FOR THE ACTUAL ARRANGEMENT OF THE TERMINALS. CONNECT POWER WIRING TO TERMINAL BLOCK 3TB ON UNITS WITHOUT ELECTRIC HEAT OR CIRCUIT BREAKER. FIGURE 16: Heat Pump Wiring Unitary Products Group...
  • Page 12: Drain Connections

    DRAIN CONNECTIONS The drain pan connections are designed to ASTM Standard D 2466 Schedule 40. Use 3/4" PVC or steel threaded pipe. Since the drains are All drain lines should be trapped a minimum of three inches, should be not subject to any pressure it is not necessary to use Schedule 40 pipe pitched away from unit drain pan and should be no smaller than the coil for drain lines.