General ................................18 Running Firmware on the Fieldbus Card ...................... 18 Operating Program ............................19 Limitation of Liability ......................20 Service, Repair ........................20 Decommissioning, Disposal ....................21 Appendix ..........................22 Further Literature ........................22 Accessories ..........................22 Industrial Performance Unit...
Safety Safety System operation assumes knowledge of the operating instructions. The Industrial Performance Unit will also be referred to in the following as “controller”. Symbols Used The following symbols are used in these operating instructions: Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury.
The device meets the requirements of section 15 of the FCC rules. Intended Use - The Industrial Performance Unit is designed for use in industrial environments. It is used as a high-performance solu- tion for 3D measuring tasks, with the connection to master control units being possible via conventional fieldbuses.
System Design The Industrial Performance Unit, referred to as “controller” for short in the following, is the link between 3D sensors and an industrial environment. The captured 3D data are computed by the Industrial Performance Unit and transmitted to a PLC, for example.
Functional Principle, Technical Data Special Performance Features The Industrial Performance Unit is characterized by its compact design while at the same time achieving high throughput of 3D points. - High-performance solution for 3D measuring tasks - Full compatibility and inline capability for customer applications...
Constant green 100 Mbit Ethernet connection established 10 Mbit Ethernet connection established Act LED (right): Green Active data transmission No data transmission Power button Switches the controller on and off Fig. 2 Controller LEDs, on/off switch Industrial Performance Unit Page 9...
Check the delivery for completeness and shipping damage immediately after unpacking. If there is damage or parts are missing, immediately contact the manufacturer or supplier. Storage Humidity: 20 ... 95% (non-condensing) Temperature range (storage) Sensor: -10 ... +50 °C Controller: -40 ... +85 °C Industrial Performance Unit Page 10...
Fig. 4 Reference points for wall and table mounting Fasten the mounting adapters to the controller using the four enclosed screws. Fasten the controller to the wall or table via the cross openings in the mounting adapter. Industrial Performance Unit Page 11...
HDMI cable Power supply 24V Fig. 6 Connecting the surfaceCONTROL 3D 32xx and surfaceCONTROL 3D 35xx reflectCONTROL LAN cable Controller Monitor 2x RJ45 connector 3DInspect (installed) HDMI cable Power supply 24V Fig. 7 Connecting the reflectCONTROL Industrial Performance Unit Page 12...
Fig. 9 Pin assignment of the power supply connection, view: Plug on housing side The operating voltage is protected against polarity reversal. Use only shielded lines or original cables from the accesso- ries program for the power supply connection or the outputs. Industrial Performance Unit Page 13...
Connect the controller to the PC. For this, use a conventional Ethernet cable of category CAT5e or higher. Connect the 3D sensor to the power supply. Connect the controller to the power supply, see Chap. 4.2.3. Industrial Performance Unit Page 14...
After the Industrial Performance Unit has been delivered, the user is responsible for carrying out security updates. For this purpose and for setting up the fieldbus connection for the Industrial Performance Unit, a user account with adminis- trator rights is set up for the user. The user is required to use these rights in a responsible manner and may only use this method of access for the aforementioned purposes.
Settings and parameters in 3DInspect only apply to the user who is currently logged in. Therefore, it is recommend- ed that the user operates 3DInspect as an Operator. As an operator, it is also possible to connect to the controller via a remote desktop connection. Industrial Performance Unit Page 16...
Set the output parameters. You can find details about control/output via fieldbus in the “Setting Up Fieldbus Opera- tion” section, see Chap. Save the parameters in a parameter set. You can find more details in the software manual for 3DInspect. Industrial Performance Unit Page 17...
Exit 3DInspect if you haven’t already. Open the control panel. To do this, click on the Windows icon and click on Control Panel. Open cifX Setup. This step requires authentication with the created administrator account. Industrial Performance Unit Page 18...
After restarting 3DInspect, the error message Input/Output: Error fieldbus startup should no longer be displayed. Operating Program The program 3DInspect is available for operating the 3D sensor. It performs industrial 3D measuring tasks and is already installed on the controller. Industrial Performance Unit Page 19...
MICRO-EPSILON or to your distributor/retail- MICRO-EPSILON undertakes no liability whatsoever for damage, loss or costs caused by or related in any way to the product, in particular consequential damage, e.g., due to...
Here you can inform yourself about the respective national collection and return points. - Old devices can also be returned for disposal to MICRO-EPSILON at the address given in the imprint at https://www.micro-epsilon.de/impressum/. - We would like to point out that you are responsible for deleting the measurement-specific and personal data on the old devices to be disposed of.
- The user manual for the MIC-770, contains details about the CPU. You can find the user manual on the D drive of the IPU. - You can find the operating instructions for the 3DInspect software among the documentation for the 3DInspect soft- ware. Accessories Fig. 10 Mounting rail dimensional drawing Industrial Performance Unit Page 22...
Page 23
Appendix | Accessories 190.8 151.5 10.4 Fig. 11 Dimensions mounting plate for DIN rail mounting Industrial Performance Unit Page 23...
Page 24
MICRO-EPSILON MESSTECHNIK GmbH & Co. KG Königbacher Str. 15 · 94496 Ortenburg / Deutschland Tel. +49 (0) 8542 / 168-0 · Fax +49 (0) 8542 / 168-90 X9751438-A012032MSC info@micro-epsilon.com · www.micro-epsilon.com Your local contact: www.micro-epsilon.com/contact/worldwide/ MICRO-EPSILON MESSTECHNIK...